INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
INSTALLATION AND
OPERATION INSTRUCTIONS
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CR97-003 ● CAN-2.21-M85 ● IAS US. 4-96
OUTDOOR
GSST8N
NATURAL GAS
GSST8P
PROPANE
Certified for Canada and United States using ANSI/CSA Methods.
SAFETY INFORMATION
!
WARNING
If the information in these instructions are not
followed exactly, a fire or explosion may result
causing property dama
ページ2に含まれる内容の要旨
2 TABLE of CONTENTS PG 2-5 INTRODUCTION 12 OPERATING INSTRUCTIONS Warranty General Instructions 13 MAINTENANCE General Information / Rates and Effi ciencies Cleaning Care of Glass and Plated Parts Dimensions 13 ADJUSTMENTS Gas Pressure Adjustment 5-7 INSTALLATION Venturi Adjustment Gas Installation Flame Characteristics Electrical Connection Clearance to Combustibles 14 REPLACEMENTS Replacement Parts 8-11 FINISHING Access
ページ3に含まれる内容の要旨
3 NAPOLEON® products are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certifi cate. NAPOLEON® products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. Th e burner and valve assembly are leak and test-fi red at a quality test station. Once assembled the complete fi replace is thoroughly inspected by a qualifi ed technician before packaging to ensure that you, the customer, r
ページ4に含まれる内容の要旨
4 GENERAL INSTRUCTIONS THIS GAS APPLIANCE SHOULD BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER to conform with local codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for example: in Massachusetts State: • The appliance off valve must be a “T” handle gas cock. • The fl exible connector must not be longer than 36 inches. • WARNING: This product must be installed by a licensed plumber or gas fi tter when installed wit
ページ5に含まれる内容の要旨
5 DIMENSIONS FIGURES 1a-c 9 /16 7 11 /16 3 49 /8 36 15 ELECTRICAL GAS LINE 1 13 1 /2 ACCESS ACCESS INSTALLATION GAS INSTALLATION Note: All gas connections must be contained within the appliance when complete. 1. The appliance is designed to accept a 1/2” gas supply line. The appliance is equipped with a 1/2” manual shut-off valve. 2. The access to the gas inlet is located in the bottom of the cabinet. 3. The shut off valve / fl ex connector assembly must always be W385-0380 contained within
ページ6に含まれる内容の要旨
6 ELECTRICAL CONNECTION FIGURE 3 ! GAS WARNING VALVE RISK OF ELECTRIC SHOCK! IGNITOR Control and valve operate with 110v. Do NOT use the appliance if any part has been IGNITOR 12 3 4 under water. Call a qualifi ed service technician WIRE IMMEDIATELY to have the appliance inspected for damage to the electrical circuit. BROWN HARD WIRING CONNECTION B L IT IS NECESSARY TO HARD WIRE THIS A G C CONTROL MODULE R W APPLIANCE. K SWITCH O H U This appliance must be electrically connected and I N T Il
ページ7に含まれる内容の要旨
7 C G D G I E K H A J B F B FIGURE 5 INSTALLATIONS CANADA U.S.A. A 8 INCHES 8 INCHES Clearance above grade, veranda porch, deck or balcony. B 12 INCHES 9 INCHES Clearance to windows or doors that open. C 12 INCHES* 12 INCHES* Clearance to permanently closed windows. D 18 INCHES** 18 INCHES** Vertical clearance to ventilated soffi t. E 12 INCHES** 12 INCHES** Vertical clearance to an unventilated soffi t. Clearance to an inside combustible corner wall or protruding F 1 INCH 1 INCH combustib
ページ8に含まれる内容の要旨
8 FINISHING TMCSS MOUNTING CABINET INSTALLATION ! WARNING Before starting the installation remove the INSTALLATION 1 protective layer from all three components that TEMPLATE make up the GSST8 (cabinet, frame, and Torch) NOTE: It is recommended that all fasteners be stainless steel. 1. Using the installation template (W122-0401) supplied, determine the best mounting location for your new Torch. (refer to your manual for clearances) Mark all 14 hole centres on the wall (surface) using the
ページ9に含まれる内容の要旨
R E HITCH PIN N I A T E E 9 RAIN TABS When shipped, the rain tabs should be at a 90º angle. Push the rain tabs down until they are at an approximate 60º angle to assist rain in running off and out of the unit. RAIN TAB FIGURE 8 DOOR REMOVAL The door is held in place at the bottom by a retainer tab FIGURE 9 that inserts into a slot in the bottom edge of the door, and at the top with a tab that secures in the same fashion. The door is removed by lifting it off the tabs. When replacing, gu
ページ10に含まれる内容の要旨
10 TFSSO FRAME INSTALLATION 1. Hang the frame onto the fi rebox by engaging the FIGURE 13 top trim bracket into the slot in the top of the frame and the bottom hooks of the frame into the slot in the mounting cabinet. FIGURE 12 TRIM SLOT BRACKET TRIM BRACKET 2. Install the trim bracket supplied in your manual baggie to the fi rebox using 3 screws. FRAME (REAR VIEW) DOOR CHAIN NOTE: If the frame needs to be secured, use two screws in the holes provided behind the control door. Insert the doo
ページ11に含まれる内容の要旨
11 ACCENT GLASS INSTALLATION Carefully sprinkle the accent glass onto the glass support ACCENT evenly. Ensure no glass falls into the burner area. If this GLASS happens, insert a clean bag into your vacuum cleaner and BURNER vacuum out the accent glass. Replacement accent glass can be purchased from your authorized dealer. FIGURE 16 GLASS SUPPORT LK8 LIGHT INSTALLATION (OPTIONAL) 1. Turn off the electrical and gas supply to the appliance. 2. Remove the frame from the unit by removing the
ページ12に含まれる内容の要旨
W a K r n E o T c 12 OPERATING INSTRUCTIONS If the appliance keeps shutting off, have it serviced. Keep After extended periods of non-operation such as following a vacation or a warm weather season, the fi replace may burner and control compartment clean. When lit for the fi rst time, the fi replace will emit a slight emit a slight odour for a few hours. This is caused by odour for a few hours. This is a normal temporary dust particles burning off. condition caused by the curing “burn-in” of int
ページ13に含まれる内容の要旨
13 MAINTENANCE TURN OFF THE GAS AND ELECTRICAL POWER BEFORE CLEANING SERVICING THE APPLIANCE. • Visually inspect the appliance for carbon buildup. CAUTION: Label all wires prior to disconnection when • Using a small whisk or brush, brush off the excess carbon servicing controls. Wiring errors can cause improper and and vacuum up or sweep into the garbage. dangerous operation. Verify proper operation after servicing. This appliance should be inspected before use and at • Check the fi re
ページ14に含まれる内容の要旨
14 REPLACEMENTS Contact your dealer for questions concerning prices and availability of replacement parts. Normally all parts can be ! WARNING ordered through your authorized dealer or distributor. Failure to position the parts in accordance with these diagrams or When ordering replacement parts always give the following failure to use only parts specified approved with this appliance may information: result in property damage or personal injury. 1. MODEL & SERIAL NUMBER OF APPLIANCE FOR
ページ15に含まれる内容の要旨
15 TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE IGNITOR AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED. SYMPTOM PROBLEM TEST SOLUTION Electrode sparks, Hot and neutral wires are - Connect the hot wire to the black wire. Connect the neutral burner ignites, reversed at control module. wire to the white wire. electrode continues to spark for Sensor / fl ame not - Raise electrode / sensor up into fl ame 1/4” above the burner. complete 7 seco
ページ16に含まれる内容の要旨
16 W415-0689 / 06.25.08 Fireplace Service History This fireplace must be serviced annually depending on usage SPECIAL CONCERNS DATE DEALER NAME SERVICE TECHNICIAN NAME SERVICE PERFORMANCE