ページ1に含まれる内容の要旨
OperatiOn and p arts Manual
MOdel ss233
subMersible puMp
Revision #2 (03/22/10)
To find the latest revision of this
publication, visit our website at:
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
pn: 020954
ページ2に含まれる内容の要旨
t able Of COntents ss233 submersible pump Table Of Contents .................................................... 2 Parts Ordering Procedures ...................................... 3 Safety Information ................................................ 4-7 Specifications .......................................................... 8 General Information ................................................. 9 Components .......................................................... 10 Operation ...............
ページ3に含まれる内容の要旨
parts Ordering prOCedures Ordering parts has never been easier! Choose from three easy options: Effective: st January 1 , 2006 best deal! order via internet (dealers only) : If you have an MQ Account, to obtain a Username Order parts on-line using Multiquip’s SmartEquip website! and Password, E-mail us at: parts@multiquip. com. View Parts Diagrams To obtain an MQ Account, contact your Order Parts District Sales Manager for more information. Print Specifi cation Information Use the int
ページ4に含まれる内容の要旨
safety infOrMatiOn Do not operate or service the equipment before reading Potential hazards associated with the operation of this the entire manual. Safety precautions should be followed equipment will be referenced with hazard symbols which at all times when operating this equipment. may appear throughout this manual in conjunction with Failure to read and understand the safety safety messages. messages and operating instructions could Symbol Safety Hazard result in injury to yourself and o
ページ5に含まれる内容の要旨
safety infOrMatiOn general SaFeTY NOTICE CauTion This equipment should only be operated by trained and qualifi ed personnel 18 years of age and older. never operate this equipment without proper protective clothing, shatterproof glasses, respiratory protection, Whenever necessary, replace nameplate, operation and hearing protection, steel-toed boots and other protective safety decals when they become diffi cult read. devices required by the job or city and state regulations. Manu
ページ6に含まれる内容の要旨
safety infOrMatiOn pump SaFeTY do noT pump water greater than 104º F. danger do noT pump liquids containing acid or alkali. alWaYS check strainer before pumping. Make sure never operate the equipment in an explosive strainer is not clogged. Remove any large objects, dirt atmosphere or near combustible materials. An or debris from the strainer to prevent clogging. explosion or fi re could result causing severe bodily harm or even death. alWaYS use a large basket strainer when pu
ページ7に含まれる内容の要旨
safety infOrMatiOn power Cord/Cable Safety liFTing SaFeTY danger CauTion never let power cords or cables lay in water. When raising or lowering of the pump is required, always attach an adequate rope or lifting device to the correct never use damaged or worn cables or cords. Inspect lifting point (handle) on the pump. for cuts in the insulation. NOTICE never grab or touch a live power cord or cable with wet hands. The do noT lift machine to unnecessary heights. possibility e
ページ8に含まれる内容の要旨
speCifiCatiOns Table 1. Specifications model SS233 Type Submersible Pump impeller Plastic Suction & discharge Size 2.00 in. (50.8 mm) 60 gallons/minute maximum pumping Capacity (227 liters/minute) 5 ft (1.5 meters) 3,318 gallons/hr (12,560 liters/hr) 10 ft (3.0 meters) 2,808 gallons/hr (10,629 liters/hr) discharge Height 15 ft (4.5 meters) 1,482 gallons/hr (8,358 liters/hr) above pumping level 20 ft (6.0 meters) 1,482 gallons/hr (5,610 liters/hr) 30 ft (9.1 meters) 300 gallons/hr (1,136 lite
ページ9に含まれる内容の要旨
general infOrMatiOn Avoid using this pump in conditions where mud, grit, silt inTroduCTion or other debris are present. These conditions could cause The SS233 submersible pump is designed to pump water blockage and cause excessive pump wear. and is used for the draining (de-watering) of flooded do no T install the pump directly into an area where there rooms, drains and fill tanks, power fountains and waterfalls is a heavy build-up of mud, grit, silt or debris. If this condition swimming
ページ10に含まれる内容の要旨
3 3 COMpOnents Figure 1. Submersible Pump Components Figures 1 shows the location of the basic components 5. Strainer base — This strainer base is made of durable for the SS233 submersible pump. Listed below is a brief plastic. DO NOT pump large objects or debris with explanation of each component. this pump. This pump is for pumping water only. For de-watering purposes, always place the strainer base 1. aC power Cable — This unit is supplied with a 20 ft. on a platform. (6.1 meters) AC po
ページ11に含まれる内容の要旨
3 3 3 3 OperatiOn 1. Attach a suitable lifting cable (rope) to the carrying 2. Make sure the pump is always placed in an upright handle (Figure 2) on the pump and lower the pump position, not tilted (Figure 3). Never position the pump into place. For applications where there is an excessive directly on a soft, loose bottom. Remember to attain amount of mud, grit or silt, the use of a support platform maximum pumping capacity and prevent excessive is desirable. When pumping water from swimmin
ページ12に含まれる内容の要旨
3 3 OperatiOn 4. NEVER! grab or touch a live power cord (Figure 4) 6. Wait a few seconds and water should begin to flow with wet hands, the possibility exists of electrical shock, from the discharge hose. electrocution and even death. 7. If water is not flowing from the discharge hose or not flowing freely after a few minutes, remove the power from the pump and check the system for leaks. pump Shut-down/Clean-up 1. Remove the power from the pump by turning off the circuit breaker or switch
ページ13に含まれる内容の要旨
trOubleshOOting Table 2. pump Troubleshooting Symptom possible problem Solution Check that proper voltage (115 VAC 1Ø) is being supplied to the pump. Also check that there is an adequate Incorrect voltage/amps? amount of current (amps) to run the pump. Check power source circuit breaker. Check electrical connections? Inspect power cord. Pump Fails To Start Replace fuse or circuit breaker. Check Blown fuse or defective circuit cause of blown fuse or tripped circuit breaker? breaker. Disc
ページ14に含まれる内容の要旨
explanatiOn Of COde in reMarks COluMn The following section explains the different symbols and QTY. Column remarks used in the Parts section of this manual. Use the numbers used — Item quantity can be indicated by a help numbers found on the back page of the manual if there number, a blank entry, or A/R. are any questions. A/R (As Required) is generally used for hoses or other NOTICE parts that are sold in bulk and cut to length. The contents and part numbers listed in the parts A blank
ページ15に含まれる内容の要旨
nOtes SS233 SubmerSible pump • opera Tion and par TS manual — rev. #2 (03/22/10) — page 15
ページ16に含まれる内容の要旨
3 3 puMp assy. page 16 — SS233 SubmerSible pump • opera Tion and par TS manual — rev. #2 (03/22/10) 1 2 3
ページ17に含まれる内容の要旨
puMp assy. no . par T no . par T name QTY. remarKS 1 020177 CABLE 20 FT 1 2 020246 FITTING, 2" NPT 1 3 SS233 SUBMERSIBLE PUMP ......................................1................CONTACT MQ UNIT SALES SS233 SubmerSible pump • opera Tion and par TS manual — rev. #2 (03/22/10) — page 17
ページ18に含まれる内容の要旨
terMs and COnditiOns Of sale — p arts 5. Parts must be in new and resalable Multiquip reserves the right to quote and paYmenT TermS condition, in the original Multiquip sell direct to Government agencies, and to Terms of payment for parts are net 30 days. package (if any), and with Multiquip part Original Equipment Manufacturer accounts numbers clearly marked. who use our products as integral parts of their FreigHT poliCY own products. 6. The following items are not returnable: All parts ord
ページ19に含まれる内容の要旨
nOtes SS233 SubmerSible pump • opera Tion and par TS manual — rev. #2 (03/22/10) — page 19
ページ20に含まれる内容の要旨
OperatiOn and p arts Manual HERE’S HOW TO GET HELP PLEASE HAVE THE MODEL AND SERIAL NUMBER ON-HAND WHEN CALLING UNITED STATES Multiquip Corporate Offi ce MQ Parts Department 18910 Wilmington Ave. Tel. (800) 421-1244 800-427-1244 Fax: 800-672-7877 Carson, CA 90746 Fax (800) 537-3927 310-537-3700 Fax: 310-637-3284 Contact: mq@multiquip.com Mayco Parts Warranty Department 800-306-2926 Fax: 800-672-7877 800-421-1244, Ext. 279 Fax: 310-537-1173 310-537-3700 Fax: 310-637-3284 310-537-3700, Ext. 279 Ser