ページ1に含まれる内容の要旨
Model : WS-8054U
433 MHz
Radio Controlled Temperature Alarm
Instruction Manual
FCC ID: OMO-01RX (receiver),
RADIO CONTROLLED
OMOTX6U (transmitter)
SET
TIME
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC
+
RULES. OPERATION IS SUBJECT TO THE
ALARM
FOLLOWING TWO CONDITIONS:
DATE INDOOR OUTDOOR
1. THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND
R
2. THIS DEVICE MUST ACCEPT INTERFERENCE
RECEIVED, INCLUDING INTERFERENCE THAT
MAY CAUSE UNDESIRED OPERATION.
Contents
Language Page
English 2
French 44
S
ページ2に含まれる内容の要旨
SIZE AA LR6 INVENTORY OF CONTENTS the exact time signal continuously throughout the United 1) WS-8054U States at 60 kHz. The signal can be received up to 2, 2) TX6U remote temperature transmitter 000 miles away through the internal antenna in the 3) Instruction manual and warranty card. Temperature Alarm. However, due to the nature of the Earth's Ionosphere, reception is very limited during ADDITIONAL EQUIPMENT (not included) daylight hours. The Temperature Alarm will search for a 1) Two fres
ページ3に含まれる内容の要旨
B) TEMPERATURE ALARM Note: After the batteries have been installed a tone 1) Remove the battery cover, located on the backside will sound, and all the LCD's (Liquid Crystal Display) will of the unit. briefly light up. The indoor temperature, the date as "1/ 2) Observe the correct polarity and install 2 AA batteries. 1", the weekday as "MON", and the remote temperature 3) Replace the battery cover. will be displayed (within three minutes). Also, the time will appear as "-:--" for approximately
ページ4に含まれる内容の要旨
3) Press and release the "SET" button to confirm the LCD and "DST" flashes where the weekday time zone setting, and to advance to DST (Daylight normally appears. saving time) setting. 2) Press and release the "+" button to turn the DST off, this will be indicated by the display of "OFF" in the III) DST (DAYLIGHT SAVING TIME) SETTING time LCD. 3) Press and release the "SET" button to confirm the Note: The DST default is "On", meaning that the WWVB DST setting and to advance to select the language
ページ5に含まれる内容の要旨
2) Press and release the "+" button to toggle between FEATURES & OPERATIONS 12 and 24 hour time. 3) Press and release the "SET" button to confirm the I) CHANGING DISPLAY MODE (DAY, SECONDS, 12/24-hour time display and to advance to select AND TEMPERATURE) either ˚F or ˚C. There are three possible display modes to view the day, seconds, and temperature. The month & date/ weekday VIII) SELECTING ˚F OR ˚C /indoor temperature/remote temperature is the default. 1) Hold down the "SET" button for 2 sec
ページ6に含まれる内容の要旨
the outdoor LCD. The remote temperature sensor B) MOUNTING WITH SCREWS transmits a new temperature to the temperature alarm 1) Remove the mounting bracket from the remote twice every 10 minutes. temperature sensor. The bracket should snap off easily. V) EL BACKLIGHT 2) Place the mounting bracket over the desired location. The EL backlight is activated for four seconds after any Through the three screw holes of the bracket, mark button is pressed. It cannot be left on continuously as it the mount
ページ7に含まれる内容の要旨
Problem: "--.-" appears in outdoor temperature LCD Note: For any questions not answered, contact La Crosse Solution: Technology with the contact information found at the 1) Check batteries in remote end of this instructional manual. 2) If batteries are replaced in remote, the unit must be re-started. Remove all batteries, and then follow start SPECIFICATIONS up procedure. Temperature: Measuring range: Problem: "OFL" appears in the outdoor temperature 32˚F to 122˚F with 0.2˚F resolution (indoor)
ページ8に含まれる内容の要旨
WARRANTY INFORMATION La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship. This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can
ページ9に含まれる内容の要旨
adjustments, claims based on misrepresentation by the seller or performance variations resulting from installation-related circumstances. LA CROSSE TECHNOLOGY, LTD WILL NOT ASSUME LIABILITY FOR INCIDENTAL, CONSEQUENTIAL, PUNITIVE, OR OTHER SIMILAR DAMAGES ASSOCIATED WITH THE OPERATION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT TO BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRODUCT IS NOT A TOY. KEEP OUT OF CHILDREN’S REACH. This warranty gives you speci
ページ10に含まれる内容の要旨
FCC DISCLAIMER This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation. La Crosse Technology Made in China All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical