ページ3に含まれる内容の要旨
Installation Precautions Adherence to the following will aid in problem-free installation with long-term reliability: WARNING - Several different sources of power can be Like all solid state electronic devices, this system may connected to the fire alarm control panel. Disconnect all operate erratically or can be damaged when subjected to light- sources of power before servicing. Control unit and associ- ning induced transients. Although no system is completely ated equipment may be damaged
ページ4に含まれる内容の要旨
Software Downloads In order to supply the latest features and functionality in fire alarm and life safety technology to our customers, we make frequent upgrades to the embedded software in our products. To ensure that you are installing and programming the latest features, we strongly recommend that you download the most current version of software for each product prior to commissioning any system. Contact Technical Support with any questions about software and the appropriate version for
ページ5に含まれる内容の要旨
Table of Contents Section 1: Product Description .............................................................................................13 1.1: Inventory......................................................................................................................................................13 1.2: Features and Options ...................................................................................................................................13 1.3: Specifications.....
ページ6に含まれる内容の要旨
Table of Contents Section 3: Programming ........................................................................................................ 61 3.1: Programming Data Entry .............................................................................................................................61 3.2: User Programming .......................................................................................................................................62 3.3: Initial Power-up..............
ページ7に含まれる内容の要旨
Table of Contents Section 4: Operating Instructions .......................................................................................150 4.1: Panel Control Buttons................................................................................................................................150 4.1.1: Acknowledge/Step...........................................................................................................................150 4.1.2: Alarm Silence ............................
ページ8に含まれる内容の要旨
Table of Contents 5.4.2: Selecting and Locating Batteries .....................................................................................................177 Appendix A: Software Zones............................................................................................... 178 A.1: Correlations...............................................................................................................................................178 Appendix B: Default Programming ...............
ページ9に含まれる内容の要旨
It is imperative that the installer understand the requirements of the Authority Having Jurisdiction (AHJ) and be familiar with the standards set forth by the following regulatory agencies: • Underwriters Laboratories Standards • NFPA 72 National Fire Alarm Code • CAN/ULC - S527-99 Standard for Control Units for Fire Alarm Systems Before proceeding, the installer should be familiar with the following documents. NFPA Standards NFPA 72 National Fire Alarm Code NFPA 70 National Electrical Cod
ページ10に含まれる内容の要旨
10 MS-9600LS Series Manual — P/N 52646:B2 2/12/2010 Notification Appliance Circuits Special Application Power Basic System Connections Power-limited, supervised circuits NAC #1 & #2 Sytle Z (Class A) 3.0 amps max per circuit EIA-232 to printer or JP8 configured for Class A personal computer using NACKEY card Special Application Power Power-limited (See Style Y illustrated 13 12 11 10 9 8 7 6 5 4 3 2 1 2 Programmable Relays & DC Power Outputs (24 VDC) for EDP-listed equipment 25
ページ11に含まれる内容の要旨
Peripheral Devices and Their Documents: Audio Control for ACC-25/50(ZS/T) Audio-Command-Center Doc. #51889 ANN-(R)LED ANN-I/O LED Display ANN-80 ANN-S/PG LED Driver Doc. #53032 Text Annunciator ANN-RLY Printer Driver Doc. #151416 Doc. #52749 Form-C Relay Card Doc. #151417 Doc. #53033 IPDACT ANN (EIA-485) TB6 Internet Communicator Doc. # 53109 DACT-UD2 Communicator J2 Connector Doc. # 53037 4XTMF Reverse Polarity module J10, J11 Connectors SLC Loop Addressable Devices and SLC Wiring Doc.
ページ12に含まれる内容の要旨
Notes 12 MS-9600LS Series Manual — P/N 52646:B2 2/12/2010
ページ13に含まれる内容の要旨
Section 1: Product Description The MS-9600LS and MS-9600UDLS are compact, cost effective, intelligent addressable FACPs (Fire Alarm Control Panels) with an extensive list of powerful features. The combination of Fire•Lite’s newer series devices and legacy 300 Series devices, along with the MS-9600LS or MS- 9600UDLS FACP, offer the latest in fire protection technology. The FLPS-7 power supply is a sep- arate board while all other electronics are contained on a single main circuit board. Both
ページ14に含まれる内容の要旨
Product Description Features and Options • Optional module for adding a second SLC loop which meets NFPA Style 4, 6 and 7 requirements • 318 addressable device capacity for each SLC loop (159 detectors and 159 control/monitor modules) • 99 software zones • Up to four onboard NACs (Notification Appliance Circuits): four Style Y (Class B) or two Style Z (Class A) • Additional NAC capability using control modules • 7.0 amps total power for NACs and 24 VDC auxiliary power outputs in alarm • Two pr
ページ15に含まれる内容の要旨
Specifications Product Description • Auto-program (learn mode) reduces installation time. Reports two devices set to the same address • Password and key-protected nonvolatile memory • User programmable password • Fully programmable from local keypad or keyboard or local PC • Compatible with Fire•Lite’s newer series addressable devices (LiteSpeed and CLIP Mode) - Refer to SLC Wiring Manual for listing of all compatible addressable devices • Compatible with legacy Fire•Lite’s 300 Series devices
ページ16に含まれる内容の要旨
Product Description Specifications Maximum signaling current per circuit: 3.00 amps (see Figure 1.1 on page 17) End-of-Line Resistor: 4.7 k , ½ watt (P/N 71252 UL listed) for NACs Refer to Device Compatibility Document for listed compatible devices Two Programmable and One Fixed Output Relay - TB1 & TB5 Contact rating: 2.0 amps @ 30 VDC (resistive), 0.5 amps @ 30 VAC (resistive) Form-C relays Refer to Figure 2.5 on page 47 for information on power-limited wiring for relay circuits Four-Wire Res
ページ17に含まれる内容の要旨
Controls and Indicators Product Description 1.3.1 Current Availability The following figure illustrates the maximum current that is possible for each panel circuit and the total current available from the FACP power supply. TB3 Resettable Special 1.5 amps max Application Power per circuit for 4-wire smoke detectors Resettable Special Standby 1.5 amps max Application Power 1.5 Amps Max* per circuit Power #1 per panel Resettable Special 1.5 amps max Application Power per circuit Power #2 Alarm
ページ18に含まれる内容の要旨
Product Description Circuits • Maintenance/presignal (yellow) • Alarm Silenced signals (yellow) • Disabled (yellow) • Battery fault (yellow) • Ground fault (yellow) Key Panel Mounted on the main circuit board, the key panel includes a window for the LCD display and LED indicators as listed above. The key panel, which is visible with the cabinet door closed, has 25 keys, including a 16 key alpha-numeric pad similar to a telephone keypad. Function keys: • Acknowledge/Step • Alarm Silence • Dril
ページ19に含まれる内容の要旨
Components Product Description NAC (Notification Appliance Circuits) Up to four NACs are provided with various programmable features: • four Style Y (Class B) NACs OR • two Style Z (Class A) NACs Relays One fixed and two fully programmable Form-C dry contact relays are provided. The fixed fail-safe relay monitors system trouble and the two programmable relays are factory default programmed for system alarm and system supervisory. Contacts are rated 2.0 amps @ 30 VDC (resisti
ページ20に含まれる内容の要旨
Product Description Components the BB-26 can be used for housing the batteries. The CHG-120F can be used for charging 26 to 120 AH batteries and the BB-55F can be used for housing the batteries. Batteries must be ordered sep- arately. 1.6.1 Intelligent Addressable Detectors: Newer Series Intelligent, addressable detectors provide information to the control panel on an SLC Signaling Line Circuit (refer to the SLC Wiring Manual for detailed information on device installation, wir- ing and oper
ページ1に含まれる内容の要旨
Addressable Fire Alarm Control Panel
MS-9600LS/MS-9600LSE
MS-9600UDLS/MS-9600UDLSE
MS-9600LSC
Manual
Document 52646
2/12/2010 Rev:B2
P/N 52646:B2 ECN 10-098
ページ2に含まれる内容の要旨
Fire Alarm System Limitations While a fire alarm system may lower insurance rates, it is not a substitute for fire insurance! An automatic fire alarm system—typically made up of Heat detectors do not sense particles of combustion and smoke detectors, heat detectors, manual pull stations, audible alarm only when heat on their sensors increases at a predeter- warning devices, and a fire alarm control panel with remote mined rate or reaches a predetermined level. Rate-of-rise notification capabi