ページ1に含まれる内容の要旨
®
UNVENTED (VENT-FREE) GAS COMPACT CLASSIC HEARTH
DUAL BURNER FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
Shown with Optional Cabinet Mantel/Hearth Base Accessory
REMOTE-READY MODELS
CDCFNRA AND CDCFPRA
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO
ページ2に含まれる内容の要旨
WARNING: Improper installation, adjustment, altera- tion, service, or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency, or the gas supplier. WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi- sions for adequate combustion and ventilation air must be provided. Refer to
ページ3に含まれる内容の要旨
SAFETY INFORMATION WARNING: Do not allow fans WARNING: This product con- to blow directly into the fireplace. tains and/or generates chemicals Avoid any drafts that alter burner known to the State of California flame patterns. Ceiling fans can to cause cancer or birth defects, create drafts that alter burner or other reproductive harm. flame patterns. Altered burner patterns can cause sooting. IMPORTANT: Read this owner’s manual carefully and completely Due to high temperatures, the befor
ページ4に含まれる内容の要旨
L I P F F O L O 12. Do not use this fireplace to cook food or burn SAFETY INFORMATION paper or other objects. Continued 13. Never place any objects in the fireplace or on 1. This appliance is only for use with the type of logs. gas indicated on the rating plate. This appliance 14. Do not use fireplace if any part has been under is not convertible for use with other gases. water. Immediately call a qualified service 2. Do not place propane/LP supply tank(s) in-
ページ5に含まれる内容の要旨
REMOVING CERAMIC BRICK LOCAL CODES LINERS Install and use fireplace with care. Follow all local codes. In the absence of local codes, use the lat- 1. Remove screws from top louver and carefully est edition of The National Fuel Gas Code ANSI remove louver (see Figure 2). Z223.1/NFPA 54*. 2. Remove ceramic brick liners with protective *Available from: packaging. The brick liners will be installed later. American National Standards Institute, Inc. 1430 Broadway 3. Remove yellow sticker from top
ページ6に含まれる内容の要旨
PROVIDING ADEQUATE HOOD ASSEMBLY VENTILATION Continued 3. Locate four black phillips sheet metal screws The following are excerpts from National Fuel in hardware packet. Gas Code, ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation. 4. Slide hood between louver and firebox top and align screw holes. All spaces in homes fall into one of the three fol- lowing ventilation classifications: 5. Insert screws as shown in Figure 3. Tighten screws firmly. 1. Unusually Tight Constructio
ページ7に含まれる内容の要旨
3. Add the Btu/Hr of all fuel burning appliances in AIR FOR COMBUSTION the space. AND VENTILATION Vent-free fireplace ___________ Btu/Hr Continued Gas water heater* ___________ Btu/Hr Confined and Unconfined Space Gas furnace ___________ Btu/Hr The National Fuel Gas Code, ANSI Z223.1/NFPA Vented gas heater ___________ Btu/Hr 54 defines a confined space as a space whose Gas fireplace logs ___________ Btu/Hr volume is less than 50 cubic feet per 1,000 Btu Other gas appliances* + _________
ページ8に含まれる内容の要旨
AIR FOR COMBUSTION Ventilated Outlet Attic AND VENTILATION Air Continued Outlet Air To Attic VENTILATION AIR Ventilation Air From Inside Building To Crawl This fresh air would come from an adjoining un- Space Inlet confined space. When ventilating to an adjoining Air unconfined space, you must provide two permanent Ventilated Inlet Air openings: one within 12" of the ceiling and one within Crawl Space 12" of the floor on the wall connecting the two spaces Figure 5 - Ventilation Air from Outd
ページ9に含まれる内容の要旨
INSTALLATION WARNING: This appliance Continued is equipped for (natural or pro- pane/LP) gas. Field conversion WARNING: Never install in a is not permitted. bedroom or bathroom. Any heat- ing product with a Btu/Hr rating INSTALLATION ITEMS over 10,000 cannot be used in a Before installing fireplace, make sure you have bedroom. the items listed below. • external regulator (supplied by installer, for CAUTION: This fireplace cre- propane/LP units only) ates warm air currents. These • pipin
ページ10に含まれる内容の要旨
INSTALLATION Continued BUILT-IN FIREPLACE INSTALLATION CAUTION: If you install the Built-in installation of this fireplace involves fireplace in a home garage installing fireplace into a framed-in enclosure. • fireplace pilot and burner must This makes the front of fireplace flush with wall. An optional brass trim kit accessory is available be at least 18 inches above (see Accessories, page 38). Brass trim will extend floor. past sides of fireplace approximately 1/2 inch. This • locate firepla
ページ11に含まれる内容の要旨
9. Check all gas connections for leaks. See Check- INSTALLATION ing Gas Connections, page 17. Continued 10. If using optional brass trim kit, install the trim after final finishing and/or painting of wall. See instructions included with brass trim ac- WARNING: If pre-wiring, do cessory for attaching brass trim. not connect wiring to any electri- IMPORTANT: When finishing your firebox, cal source at this time. combustible materials such as wall board, gypsum Install fireplace electrical outlet
ページ12に含まれる内容の要旨
L I P F F O L O INSTALLATION OPTIONAL MANTEL INSTALLATION Continued efer t i str cti s r i e it t Note: R o n u on p ov d d w h he mantel for assembly instructions. Refer to the Mantel Clearances for Built-In following instructions for system installation. Installation Refer to instructions on page 6 for hood assembly. If placing mantel above built-in fireplace, you must Blower accessory should be installed if it is being meet minimum clearance between mantel shelf and used (see Installin
ページ13に含まれる内容の要旨
L I P F F O L O Assembling Perimeter Trim (Perimeter INSTALLATION trim shipped with mantel) Continued 1. Remove packaging from three remaining 12. Install gas line. See Connecting To Gas Sup- pieces of trim. ply, page 16. 2. Locate two adjusting plates with set screws, 13. Check for leaks. See Checking Gas Connec- and two shims in the hardware packet. tions, page 17. 3. Align shim under adjusting plate as shown in 14. Place mantel around fireplace. Be careful
ページ14に含まれる内容の要旨
L I P F F O L 3 2 1 O 5. In top of the fireplace cabinet, locate the four INSTALLATION mounting holes on the outer casing. Align Continued these four holes with those on the blower Installing Blower Accessory bracket assembly. Attach blower bracket as- sembly to the outer casing with 4 #10 screws CAUTION: Label all wires provided (see Figure 14). prior to disconnection when 6. Route the wire harness through the hole in left servicing controls. Wiring erro
ページ15に含まれる内容の要旨
L I P F F O L 3 2 1 O 5. Test to make sure blower is working properly. INSTALLATION 6. Reinstall upper louver beginning with bottom Continued screws (see Figure 11, page 12) and close For Built-In Installation lower louver. Fan Switch WARNING: A licensed elec- (Auto/Off/On) 1 Auto 2 trician must connect the wiring Off 3 Blue Thermostat Switch harness to electrical supply On (N.O.) Blue following all local codes. Electri- 110/115 Red V.A.C. Blower Motor c
ページ16に含まれる内容の要旨
Installation must include an equipment shutoff INSTALLATION valve, union, and plugged 1/8" NPT tap. Locate Continued NPT tap within reach for test gauge hook up. NPT CONNECTING TO GAS SUPPLY tap must be upstream from heater (see Figure 20). IMPORTANT: Install equipment shutoff valve WARNING: This appliance in an accessible location. The equipment shutoff requires a 45° male flare fitting valve is for turning on or shutting off the gas to 5/8"-18 UNF (Unified National Fine the appliance. T
ページ17に含まれる内容の要旨
L I P F F O L O INSTALLATION Continued We recommend that you install a sediment trap in supply line as shown in Figure 20, page 16. Locate sediment trap where it is within reach for cleaning. Install in piping system between fuel supply and heater. Locate sediment trap where trapped mat- ter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into fireplace controls. If sediment trap is not installed or is installed wrong, fireplace may not
ページ18に含まれる内容の要旨
Equipment INSTALLATION Gas Control Valve Shutoff Continued Valve Propane/LP CAUTION: Make sure exter- Supply nal regulator has been installed Tank between propane/LP supply and fireplace. See guidelines under Connecting to Gas Supply, page 16. PRESSURE TESTING GAS SUPPLY PIPING Figure 24 - Checking Gas Joints SYSTEM (Propane/LP Only) Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect appliance with its appliance main gas valve (control valve) and equipment Gas Control Valve
ページ19に含まれる内容の要旨
Installing 9-Volt Battery in Hand-Held INSTALLATION Remote Control Unit Continued 1. Remove battery cover on back of remote OPTIONAL WIRELESS HAND-HELD control unit. REMOTE CONTROL ACCESSORIES 2. Attach terminal wires to the battery (not includ- ed). Place battery into the battery housing. Installing Receiver 3. Replace battery cover onto remote control unit. 1. Disconnect wires from the control valve (see Figure 26). Battery 2. Locate the battery clip mounted on the back Remote Control U
ページ20に含まれる内容の要旨
INSTALLATION Terminal “W” Continued W 4. Gently remove the cover of the thermostat from the base. Grasp the sides of the cover firmly and pull to separate from the base. 5. Feed the electrical wires through the rectangular Terminal “R” R slots on each side of the base (see Figure 31). WARNING: Do not con- Figure 32 - Thermostat Base Terminals nect the thermostat to a power “W” and “R” source. Electrical shock and/or OPTIONAL WALL SWITCH - GWMS2 a fire hazard will occur. WARNING: Read and f