ページ1に含まれる内容の要旨
ELECTRIC COUNTER TOP GRIDDLE
WITH CHEESEMELTER
OPERATION MANUAL
EL-1624T
EL-1636T
EL-1624T Shown
CECILWARE CORPORATION
th
43-05 20 AVENUE, LONG ISLAND CITY, NEW YORK 11105-1295 ■
718-932-1414 FAX 718-932-7860 www.cecilware.com
NN22A 5/05
ページ2に含まれる内容の要旨
TABLE OF CONTENTS Introduction ............................................................... page 2 Packaging .................................................................. page 2 Installation ................................................................. page 2 Operation ................................................................... page 3 Cleaning, Care and Maintenance ............................. page 3 Safety ........................................
ページ3に含まれる内容の要旨
Introduction Congratulations on the purchase of your Cecilware Griddle/Cheesemelter. Please take a few moments to carefully read through this manual to ensure that the machine is operated and maintained properly. This will enable the best possible performance from this product for many years. Cecilware will not accept liability for the following if: * The instructions in this manual have not been followed correctly. * Non-authorized personnel have tampered with the machine. * Non-or
ページ4に含まれる内容の要旨
Operation Your Griddle/Cheesemelter should be turned on prior to usage to allow the cooking surface to warm up; 5 minutes should be sufficient. To get efficient use out of this unit while in intermittent use, it is recommended that the thermostat be turned down, when not cooking. This will assist in reducing power consumption and also allow for a quicker heating response when needed. Cecilware recommends that the cooking surface be lightly greased before each use. For cheesemelting o
ページ5に含まれる内容の要旨
Safety *A Cecilware Recommended Qualified Service Technician should carry out repairs if necessary. Do not remove any components or service panels on this product. *Switch off power to and disconnect from the power source while cleaning. *Allow the Griddle/Cheesemelter to cool down after using before dismantling for cleaning; the unit will still be too hot to handle immediately after use . *Do not immerse in water or use hose to clean. *If the power cord is damaged, it must b
ページ6に含まれる内容の要旨
Trouble Shooting Cont… Problem Cause Remedy 1. Call service agent or qualified 1. Faulty element(s) technician 2. Ensure that the thermostat is set Indicator light is on but the unit 2.Operation of correctly, also ensure the dial is not is not heating thermostat spinning on the thermostat and giving the wrong reading 3. Call service agent or qualified 3. Faulty thermostat technician 1. Ensure that the plates are kept clean 1.Carbon build up and free of carbon build up 2. Ensur
ページ7に含まれる内容の要旨
Electrical Diagram Model: EL-1624T: 240V on/off switch thermostat pilot light heating element EL-1636T: 240V on/off on/off switch 1 switch 2 thermostat 1 thermostat 2 pilot light 1 pilot light 2 heating heating element 1 element 2 The above circuit diagram has been provided to assist qualified technicians. A Recommend Qualified Service Technician should carry out repairs if needed. Do not remove any components or service panels on this product. 6
ページ8に含まれる内容の要旨
Explosion View MODEL: EL -1624T 2 3 4 5 6 7 8 14 9 10 11 13 12 7
ページ9に含まれる内容の要旨
MODEL: EL – 1636T 2 3 4 5 7 6 8 10 9 14 13 11 12 8
ページ10に含まれる内容の要旨
Spare Parts List EL-1624T EL-1636T No. Description QTY Part NO. QTY Part NO. 1 GRIDDLE PLATE 1 NA 1 NA 2 ELEMENT CLAMP (UPPER) 2 NA 2 NA 3 ELEMENT FIXING PALTE 1 08036 2 08043 4 ELEMENT CLAMP (LOWER) 3 NA 4 NA 5 THERMOSTAT 1 08078 2 08078 6 PILOT LIGHT 1 08067 2 08067 7 THERMOSTAT DIAL 1 08041 2 08041 8 GRILLING RACK 1 08037 1 08044 9 CRUMB TRAY 1 08038 1 08045 10 ON/OFF SWITCH 1 08054 2 08054 11 DRIP TRAY 1 08039 1 08039 12 FEET 4 080040 4 08040 13 BASE PLATE 1 NA 2 NA 14 C
ページ11に含まれる内容の要旨
Specifications CECILWARE POWER DIMENSIONS (inches) VOLTAGE MODEL (watts) W×D×H EL-1624T 2400 24”×22”×12 1/4” 240V 60HZ EL-1636T 3600 36”×22”×121/4” 10
ページ12に含まれる内容の要旨
CECILWARE CORPORATION th 43-05 20 AVENUE, LONG ISLAND CITY, NEW YORK 11105-1295 ■ 718-932-1414 FAX 718-932-7860 www.cecilware.com 11