ページ1に含まれる内容の要旨
TRADITION SERIES P23
P23FSL P23I P23FSA
OWNER’S MANUAL
• WARNING: If your appliance is not properly installed a house fire may result. For your safety,
follow the installation directions. Contact local building or fire officials about restrictions and
installation inspection requirements in your area.
• PLEASE read this e
ページ2に含まれる内容の要旨
2 INTRODUCTION Thank you for purchasing the Breckwell Pellet Burning Stove. You are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you do all three. PLEASE read this entire manual before installation and use of this pellet fuel-burning
ページ3に含まれる内容の要旨
SAFETY PRECAUTIONS 3 • Do not operate your stove if you • Keep foreign objects out of the smell smoke coming from it. Turn it off, hopper. monitor it, and call your dealer. • Never use gasoline, gasoline- • Do not throw this manual away. type lantern fuel, kerosene, charcoal lighter This manual has important operating and fluid, or similar liquids to start or “freshen maintenance instructions that you will need at up” a fire in this stove. Keep all such liquids a later time. Always
ページ4に含まれる内容の要旨
4 TABLE OF CONTENTS INTRODUCTION --------------------------------------------------------------------------------------------- 2 SAFETY PRECAUTIONS ---------------------------------------------------------------------------------- 3 SPECIFICATIONS ------------------------------------------------------------------------------------------- 5 INSTALLATION --------------------------------------------------------------------------------------------- 5 Preparation ---------------------------
ページ5に含まれる内容の要旨
INSTALLATION 5 SPECIFICATIONS FREESTANDING: Width: 22 ½” Height: 29” (with pedestal), 28 ½” (with legs) Depth: 27” (excluding ash lip) Weight: 210 lbs. Pedestal: 40 lbs. Legs: 13 lbs. Flue size: 3” or 4” Hopper Capacity: Up to 60 lbs. (this can vary widely depending on pellet size, length, and diameter) FIGURE 1 EPA status: exempt Burn time: 1 lb. to 5 lbs. per hour BTU range: 8,200 to 47,000 Approved installations: mobile home, alcove, conventional FIREPLAC
ページ6に含まれる内容の要旨
6 INSTALLATION COMBUSTION AIR SUPPLY For a mobile home installation the stove must be connected to an outside source of combustion air. A 2” inside diameter metallic pipe, either flexible or rigid, may be attached to the inlet at the stove’s rear (refer to figures 5 and 6). A rodent guard (minimum ¼” wire mesh)/wind hood must be used at the terminus (refer to figure 7). All connections must be secured and airtight by either using the appropriately sized hose clamp and/or UL-181-AP foil
ページ7に含まれる内容の要旨
INSTALLATION 7 Equivalent Vent Length (EVL) The longer the run of pipe in your installation (both with insert and freestanding models), the more restriction there is in the system. Therefore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of equivalent vent length. • Horizontal runs shall not exceed 10 feet of EVL. • Recommended vertical runs to be a minimum of 8 feet. • To calculate EVL, use the following conversions: 90º elbow or “T” = 5 equivalent
ページ8に含まれる内容の要旨
8 INSTALLATION B. HORIZONTALLY THROUGH WALL (refer to Figure 9) NOTE: Follow L-Vent chimney manufacturer’s instructions. 1. Position stove, adhering to clearances shown in Figures 1 & 2. 2. Locate position of hole in wall; directly behind stove exhaust vent (refer to figure 5). 3. Always maintain 3” clearance from combustible materials. 4. Install L-Vent wall thimble per L-Vent manufacturer’s instructions. 5. Attach enough piping to penetrate and extend at least 6” bey
ページ9に含まれる内容の要旨
9 INSTALLATION B. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 10) NOTE: Follow L-Vent chimney manufacturer’s instructions. OPTION: To achieve a center vertical installation a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove. OPTION: Install L-Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark point on ceiling. Install ceiling support and L-Vent pipe per L-Ven
ページ10に含まれる内容の要旨
10 INSTALLATION D. VERTICALLY INTO EXISTING MASONRY FIREPLACE NOTE: Follow L-Vent chimney manufacturer’s instructions. 1. Have the masonry chimney inspected by a qualified chimney sweep or installer to determine its structural condition. 2. You will need a pipe length equal to the chimney height from the hearth. If outside combustion air is to be used, you will need a pipe length equal to the chimney height plus 18 inches. 3. Install a blanking plate and the chimney pipe, a
ページ11に含まれる内容の要旨
INSTALLATION 11 INSERT INSTALLATIONS Insert installations must be vented with 3” or 4” pipe. Pipe may be single wall stainless steel flexible pipe. Vent may terminate within chimney beyond a blanking plate or extend to the chimney top. See “COMBUSTION AIR SUPPLY” for outside air access information. The fireplace and chimney should be cleaned thoroughly before starting the installation. We suggest painting the interior of particularly old and dirty fireplaces to seal any odors. I
ページ12に含まれる内容の要旨
12 INSTALLATION B. WHEN VENT PIPE EXTENDS TO CHIMNEY TOP (Refer to Figures 16 and 17) 1. You will need a pipe length equal to the chimney height (from hearth) plus 6 inches. If outside combustion air is to be used, you will need a pipe length (see “COMBUSTION AIR SUPPLY”) equal to the chimney height plus 12 inches. 2. Attach cerablanket wrap to that end of vent pipe that will connect to the stove. Use 12-inch lengths of light gauge metal wire (not included) or metallic ta
ページ13に含まれる内容の要旨
INSTALLATION 13 D. AS A BUILT-IN FIREPLACE Figures 18 and 19 describe a P23 installation vented into either a special chase built outside an outer wall or a false inside wall. This is especially suited for new construction or remodeling. The equipment compartment (sides and rear of the stove in fireplace) must be enclosed per the applicable electrical standards. NOTE: Floor protection for Built-in raised hearths requires a continuous sheet beneath to prevent the possibility of e
ページ14に含まれる内容の要旨
14 INSTALLATION E. INSTALLATION IN TO A FACTORY BUILT (METAL) FIREPLACE (Refer to figure 20) When installing into a factory built fireplace, the firebox must accept the insert without modification other than removing bolted or screwed together pieces such as smoke shelf/deflectors, ash lips, screen or door tracks and damper assemblies. These items must be reinstalled to restore the fireplace to its original operating condition if the insert is removed and not repl
ページ15に含まれる内容の要旨
OPERATION 15 PANEL CONTROLS (See Figure 21) The blowers and automatic fuel supply are controlled from a panel on the left-hand side of the P23. The control panel functions are as follows. a. ON/OFF SWITCH • When pushed the stove will automatically ignite. No other firestarter is necessary. The igniter will stay on for at least 10 and up to 15 minutes, depending on when Proof of Fire is reached. The fire should start in about 5 minutes. • The green light locate
ページ16に含まれる内容の要旨
16 OPERATION PROPER FUEL THIS STOVE IS APPROVED FOR BURNING PELLETIZED WOOD FUEL ONLY! Factory-approved pellets are those ¼” or 5/16” in diameter and not over 1” long. Longer or thicker pellets sometimes bridge the auger flights, which prevents proper pellet feed. Burning wood in forms other than pellets is not permitted. It will violate the building codes for which the stove has been approved and will void all warranties. The design incorporates automatic feed of the pellet fuel into the
ページ17に含まれる内容の要旨
OPERATION 17 RE-STARTING A WARM STOVE If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds. IF STOVE RUNS OUT OF PELLETS The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes. After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes. After the 10 minutes the “3” light on the bar graph will flash and
ページ18に含まれる内容の要旨
THERMOSTAT INSTALLATION OPTIONAL THERMOSTAT A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fixed wall mount or Breckwell’s hand held model can be used. The control panel can be set up two ways to operate your stove in thermostat mode. THERMOSTAT INSTALLATION • A MILLIVOLT THERMOSTAT IS REQUIRED. • Unplug stove from power outlet. • Remove control board from stove. • The two thermostat wires
ページ19に含まれる内容の要旨
OPERATION 19 OPERATING SAFETY PRECAUTIONS PLEASE READ THIS! a. Hot while in operation. Keep children, clothing, and furniture away. Contact may cause skin burns. b. If you notice a smoldering fire (burnpot full but no visible flame) AND a heavy smoke buildup in firebox, immediately TURN OFF the stove, but DO NOT unplug it. Do not open the door, change the damper setting or tamper with any controls on the stove. Wait until firebox clears, and blowers shut down, do as instructed in “P
ページ20に含まれる内容の要旨
20 MAINTENANCE FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER CLEAN WHEN HOT. NOTE: Inspect burn pot periodically to see that holes have not become plugged, if so, clean thoroughly. ASH REMOVAL Ashes should be placed in a metal container with a tight-fitting lid. The closed container or ashes should be placed on a noncombustible surface or on the ground, well away from all combustible materials pending final disposal