ページ1に含まれる内容の要旨
Radio-Controlled Clock with Barometer
(Model #: PS-S01/PS-S01U)
User Manual
EN
ページ2に含まれる内容の要旨
Safety and care ..................................................... 12 TABLE OF CONTENTS Warnings ............................................................... 12 Additional resources .............................................. 1 Troubleshooting ..................................................... 12 About this guide .................................................... 2 Specifications ........................................................ 14 Product overview ..........................
ページ3に含まれる内容の要旨
In this box, you will find: ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck • Main unit with Oregon Scientific Radio-Controlled Clock with • Batteries Barometer (PS-S01/PS-S01U). This powerful device bundles time keeping, alarm, barometric trend, and weather forecasting features into a single tool you can use from the convenience of your home. Keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical sp
ページ4に含まれる内容の要旨
DESCRIPTIONS PRODUCT OVERVIEW 1. Snooze/Light button ( 8,11) TOP AND BOTTOM VIEWS 2. Reset button ( 6, 11) 3. Battery compartment ( 6) 1 2 3 3 EN
ページ5に含まれる内容の要旨
LCD DISPLAY DESCRIPTIONS 1. Low battery icon ( 6) 2. Clock ( 6) 3. Weather forecast ( 11) 4. Calendar ( 8, 9) 5. Radio signal icon ( 7) 6. Barometer ( 9) 7. Alarm ( 8) 4 EN
ページ6に含まれる内容の要旨
BACK VIEW BUTTON DESCRIPTIONS 1. Up – increase setting / activate auto-synch ( 7) 2. Down – decrease setting / deactivate auto-synch ( 7) 3. Select – switch modes / change settings ( 6) 4. Alarm –activate / deactivate alarm ( 8) 1 3 2 4 5 EN
ページ7に含まれる内容の要旨
CHANGE SETTINGS GETTING STARTED Press and hold SELECT for 2 seconds. Then, press UP BATTERIES or DOWN to change each setting. Press SELECT to Batteries are supplied with this product. Replace them switch between options. whenever the low battery signal ( ) displays. Remove the compartment lid on the bottom of the unit. Be sure to match the correct polarity, as shown in the battery compartment. Before you close the lid, press the RESET CLOCK button with the point of a blunt object (such as a
ページ8に含まれる内容の要旨
RECEPTION TO DISABLE OR ENABLE Reception takes 2 – 10 minutes to complete. Once AUTO-SYNCHRONIZATION complete, the icon will stop blinking. In Clock mode, press DOWN for 2 seconds to disable the auto-synchronization. The unit will not respond to radio signals until you reactivate the synchronization. Strong signal Weak signal No signal To enable auto-reception, press UP for 2 seconds. SET OR CHANGE THE CLOCK NOTE For best results, place the unit away from metal or 1. Press SELECT to switch to
ページ9に含まれる内容の要旨
SNOOZE ALARM Press the SNOOZE/ LIGHT button the top of the unit to When activated, the Beep Alarm starts quietly, then temporarily disable the alarm for 8 minutes. The alarm icon gradually becomes louder. It shuts off after two minutes. will blink while Snooze is activated. The LCD display lights up for the first 8 seconds. TO TURN THE ALARM OFF OR ON SET ALARM Press any button to stop the alarm. 1. Press SELECT several times until the Alarm area flashes. To turn the alarm off completely (d
ページ10に含まれる内容の要旨
1. Press SELECT several times until the calendar area BAROMETER flashes. This product tracks barometric pressure changes over the 2. Press and hold SELECT for 2 seconds to enter the past 24 hours to provide the weather forecast ( 11) and calendar setting mode. a trend line showing the direction of barometric change. 3. Select the year, month, date, and language. Press UP or DOWN to change the setting. Press SELECT to confirm. NOTE The language options are (E) English, (F) French, (D) German,
ページ11に含まれる内容の要旨
BAROMETRIC END VIEW THE LAST 24 HOURS The barometric trend arrow for the last 30 minutes is Press SELECT 2 times until the Barometer Area flashes. always displayed. Then, press UP or DOWN to view the last 24 hours history. Trend Description Pressure change SET UNIT AND ALTITUDE (mb/hPa) You can set the unit of measurement (mb/hPa or inHg) and 1 hr 6 hrs altitude. Setting the altitude allows the product to take Rising +1 +3 more accurate barometric measurements. 1. Press SELECT 2 times until th
ページ12に含まれる内容の要旨
WEATHER BACKLIGHT FORECAST Press SNOOZE/ LIGHT to illuminate the backlight for 5 This product forecasts the next 12 to 24 hours of weather seconds. within a 30 to 50 km (19 - 31 mile) radius with 70 to 75 percent accuracy. The weather forecast is always RESET SYSTEM displayed. The RESET button is located in the battery compartment. Press it with the tip of a blunt object (such as a ballpoint Partly pen) whenever you change the batteries, or whenever Clear Rainy Cloudy Cloudy performance is not
ページ13に含まれる内容の要旨
• Do not use rechargeable batteries with this product. SAFETY AND CARE • Remove the batteries if storing this product for a Wash the unit with a slightly damp cloth and mild detergent. long period of time. Avoid dropping the unit or placing it in a high-traffic • Do not scratch the LCD display. location. • Do not make any changes or modifications to this product. Unauthorized changes may void your right WARNINGS to use the product. This product is designed to give you years of service if • The
ページ14に含まれる内容の要旨
Problem Symptom Remedy Problem Symptom Remedy If it still fails, you may be Calendar Strange date Change language / month too far from a signal. ( 9) Clock Cannot 1. Remove batteries. Cannot change Disable auto-synchronize 2. Press RESET. All auto-synchronization clock memory items will ( 7) return to default. Baro Strange Set altitude / unit ( 10) 3. Replace batteries. reading 4. Place clock near window / away from electrical devices, and SPECIFICATIONS wait 10 – 20 minutes. 13 EN
ページ15に含まれる内容の要旨
Trend 1 mb change in 1 hour or 3 mb change SPECIFICATIONS in 6 hours Dimensions: Radio-controlled clock L x W x H 75 x 36 x 78.3 mm Synchronization Auto or disabled (3 x 1.42 x 3.08 in) Clock display HH:MM:SS Weight 169 grams with battery Hour format 12hr AM/PM (MSF format) 24hr (DCF format) Barometer Calendar DD/MMM; weekday selection in 5 Unit mb/hPa or inHg languages (E, D, F, I, S) Range 500 to 1050 mb/hPa Alarm 2 minute crescendo (14.77 to 31.01 inHg) Snooze 8 minutes Resolution 1 mb (0.03
ページ16に含まれる内容の要旨
EC-DECLARATION OF CONFORMITY Additional information: This product complies with the essential requirements of The product is therefore conform with the Low Voltage Article 3 of the R&TTE 1999/5/EC Directives, if used for Directive 73/23/EC, the EMC Directive 89/336/EC and its intended use and that the following standard(s) has/ R&TTE Directive 1999/5/EC (appendix II) and carries the have been applied: respective CE marking. Efficient use of radio frequency spectrum VS-Villingen / Germany Augus