Installation Instructions
for Stacked Washers and Dryers
Inside.....................................
Dimensions........................................................................ 2
Before You Start................................................................ 4
Installation......................................................................... 5
Installer Checklist........................................................... Back Cover
Date Purchased ________________
Model Number ________
ページ2に含まれる内容の要旨
WARNING FOR YOUR SAFETY, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. W033 � Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. � WHAT TO DO IF YOU SMELL GAS: – Do not try to light any appliance. – Do not touch any electrical switch; do not use any phone in your building. – Clear the room, building or area of all occupants. – Imme
ページ3に含まれる内容の要旨
Dimensions 23.5 in. (59.7 cm) 8.0 in. (20.3 cm) 15.4 in. (39.1 cm) 5.25 in. (13.3 cm) 24 in. (61 cm) *13.1 in. (33.3 cm) 28 in. 26.9 in. *14.6 in. (71.1 cm) (68.3 cm) (37.08 cm) 2.0 in. (5.1 cm) SWD829N ELECTRIC DRYERS SWD829N * With leveling legs turned into base. 23.5 in. (59.7 cm) 8.0 in. (20.3 cm) 15.4 in. (39.1 cm) 1 5.25 in. (13.3 cm) 2.3 in. (39.1 cm) 24 in. (61 cm) *13.1 in. (33.3 cm) 28 in. 26.9 in. *14.6 in. (71.1 cm) (68.3 cm) (37.08 cm) 2.0 in. (5.1 cm) GAS DRYERS SWD830N SWD830N *Wi
ページ4に含まれる内容の要旨
" 6 1 / 9 Before You Start WARNING Supplies Any disassembly requiring the use of For most installations, the basic supplies you will need tools must be performed by a suitably are: qualified service person. W299 1 3 2 NOTE: If the the unit is delivered on a cold day (below freezing), or is stored in an unheated room or area during the cold months, do not attempt to 5 operate it until the unit has had a chance to warm up. 6 NOTE: Some moisture in the wash drum is normal. 4 7 Water is used
ページ5に含まれる内容の要旨
Water Supply Installation Water supply faucets must fit standard 3/4 inch Step 1: Position Unit Near Installation (19.1 mm) female garden hose couplings. DO NOT Area USE SLIP-ON OR CLAMP-ON CONNECTIONS. Move unit as close to the desired area of installation as Water supply faucets should be readily accessible to possible. permit turning them off when washer is not being used. o WARNING Recommended cold water temperature is 60 to o o o 80 Fahrenheit (16 to 27 Celsius). Recommended o o Wa
ページ6に含まれる内容の要旨
IMPORTANT: Hoses and other natural rubber Connecting Hoses parts deteriorate after extended use. Hoses may Remove the two plain rubber washers and two filter develop cracks, blisters or material wear from the screens from the accessories bag. Install them into temperature and constant high pressure they are each end of the fill hoses as shown in Figure 2. The subject to. screen must be facing outward. All hoses should be checked on a yearly basis for Screw hose couplings with the filter
ページ7に含まれる内容の要旨
Risers Step 3: Connect Drain Hose to Drain Receptacle Risers (or air cushions) may have to be installed if the pipes knock or pound when flow of water stops. The Remove the drain hose from its shipping position on risers are more efficient when installed as close as the rear of the washer by unhooking the hose from the possible to the water supply faucets (refer to Figure 4). retainer clamp and by removing the shipping tape. Install the drain hose into the drain receptacle (standpipe, wal
ページ8に含まれる内容の要旨
Wall Installation: Laundry Tub Installation: For installations of this type, the drain hose MUST be For this type of installation, the drain hose MUST be secured to one of the fill hoses using the beaded strap secured to the stationary tub to prevent hose from from accessories bag. Refer to Figure 6. dislodging during use. Refer to Figure 7. Use the beaded strap (supplied in accessories bag) to secure NOTE: End of drain hose must be below 24 in. hose. (61 cm). 1 1 2 3 2 SWD600N SWD600N H023
ページ9に含まれる内容の要旨
Step 4: (Gas Dryer Only) Connect Gas Natural Gas Altitude Adjustments Supply Pipe Altitude Orifice Size Part No. feet m No. inches mm WARNING 3000 915 43 0.0890 2.26 503778 6000 1830 44 0.0860 2.18 58719 To reduce the risk of gas leaks, fire or 8000 2440 45 0.0820 2.08 503779 explosion: 9000 2740 46 0.0810 2.06 503780 � The dryer must be connected to the type 10,000 3050 47 0.0785 1.99 503781 of gas as shown on nameplate located in Table 1 the door recess. � Use a new flexible stainless ste
ページ10に含まれる内容の要旨
NOTE: The dryer and its appliance main gas valve Grounding Information must be disconnected from the gas supply piping � This dryer must be connected to a grounded system during any pressure testing of that system metal, permanent wiring system; or an at test pressures in excess of 1/2 psi (3.45 kPa). equipment-grounding conductor must be run Refer to Step 12 (Check Heat Source). with the circuit conductors and connected to the 3 equipment-grounding terminal or lead on the L.P. (Liquefi
ページ11に含まれる内容の要旨
Connecting Power Cord with Three-Wire Plug NOTE: Four-wire cord is required for mobile homes or where codes do not permit grounding through neutral. NOTE: The power cord is NOT supplied with the electric dryer. Type of power cord and gauge of wire must conform to local codes and instructions. POWER SUPPLY POWER SUPPLY 1 The method of wiring the dryer is optional and subject to local code requirements. 2 NOTE: Connect the dryer to the power supply with the MAXIMUM RATED VOLTAGE listed on th
ページ12に含まれる内容の要旨
120 ± 12 V.A.C. 120 ± 12 V.A.C. 4. Use the three screws from the accessories bag to Connecting Power Cord with Four-Wire Plug attach the power cord wires to the terminal block. NOTE: Four-wire cord is required for mobile Refer to Figure 12. homes or where codes do not permit grounding through neutral. 1 2 2 1 3 4 3 D286I 240 ± 12 0 1 “L1” Terminal V.A.C. V.A.C. 2 Neutral Terminal 3 “L2” Terminal Figure 12 DRY2016N 5. Tighten all screws firmly. 1 Typical Four-Wire Receptacle IMPORTANT: Failu
ページ13に含まれる内容の要旨
3. Remove ground screw and save for use in Step 5. 5. Attach power cord ground (green) wire to rear Remove wire and use in Step 6. bulkhead using ground screw removed in Step 3. 1 1 7 6 5 2 4 D697I D697I 1 Ground Screw DRY1920N 3 Figure 15 DRY1920N 1 White 4. Use a strain relief and insert end of power cord 2 “L2” Terminal through power supply hole. 3 Black 4 Green 5 Red 6 Neutral Terminal 7 “L1” Terminal Figure 17 6. Use the three screws from the accessories bag to attach the remaining pow
ページ14に含まれる内容の要旨
� Locate dryer so exhaust duct is as short as Step 6: Connect Dryer Exhaust System possible. � Be certain old ducts are cleaned before installing WARNING your new dryer. � Use 4 inch (102 mm) diameter rigid or flexible To reduce the risk of fire and combustion metal duct. gas accumulation the dryer MUST be exhausted to the outdoors. � The male end of each section of duct must point W604 away from the dryer. To reduce the risk of fire and the � Use as few elbows as possible. accumulation o
ページ15に含まれる内容の要旨
Exhaust Direction Exhaust System The dryer can be exhausted to the outdoors through the For best drying results, recommended maximum back, left, right or bottom of the dryer. EXCEPTION: length of exhaust system is shown in Table 3. Gas dryers cannot be vented out the left side To prevent backdraft when dryer is not in operation, because of the burner housing. outer end of exhaust pipe must have a weather hood Dryer is shipped from factory ready for rear exhaust. with hinged dampers (obtain l
ページ16に含まれる内容の要旨
Step 7: Position and Level the Unit Position unit so it has sufficient clearance for installation and servicing. Refer to Figure 19. C D E E A B SWD795N Dryer and Exhaust Duct Clearances Area Description Minimum Clearance A Left Dryer Side 0 in. (0 cm) B Right Dryer Side 1 in. (2.54 cm) C Dryer Top 6 in. (15.24 cm) D Dryer Rear 4 in. (10.2 cm) E Exhaust Duct Clearance to Combustible Materials 2 in. (5.1 cm) NOTE: Shaded areas indicate adjacent structure. SWD795N Figure 19 NOTE: Use of the disp
ページ17に含まれる内容の要旨
Place a level on the cabinet top and check if the unit is level from side to side and front to back. NOTE: Level must rest on raised portion of top panel. Refer to Figure 20. 1 5 1 4 3 SWD832N 1 Wood Block 2 SWD833N Figure 21 1 Level Make sure that the unit does not rock. When unit is 2 Rubber Foot level and does not rock, tighten locknuts securely 3 Leveling Leg against bottom of unit base. If these locknuts are not 4 Locknut tight, unit will move out of position during operation. 5 Unit
ページ18に含まれる内容の要旨
IMPORTANT: DO NOT tip washer more than Step 8: (Washer Only) Remove the Shock 6 inches (152.4 mm) in any direction after shipping Sleeves and Shipping Brace brace has removed. Shock absorbers may separate Remove front access panel by removing the two and damage to unit may result. For leveling screws at the bottom of the panel. purposes, the unit may be tilted a maximum of 6 inches (152.4 mm) in any direction. Remove the five bolts and lockwashers from shipping brace with 9/16 inch wrenc
ページ19に含まれる内容の要旨
The dryer is designed to be operated on a separate Step 10: Plug In the Washer and Dryer branch, polarized, three-wire, effectively grounded, Electric Dryer 120 Volt, 60 Hertz, AC (alternating current) circuit protected by a 15 Ampere fuse, equivalent fusetron or Connect the dryer to an electrical power source. Refer circuit breaker. to Step 4 for information on connecting power cord. The three-prong grounding plug on the power cord should be plugged directly into a polarized three-slot e
ページ20に含まれる内容の要旨
Washer WARNING Washer requires 120 Volt, 60 Hertz electrical supply and comes equipped with a 3-prong grounding plug. To reduce the risk of an electric shock or Refer to serial plate for specific electrical fire, DO NOT use an extension cord or an requirements. adapter to connect the dryer to the electrical power source. NOTE: The wiring diagram is located behind the W037 control panel, inside the control cabinet. 2 3 1 2 1 3 120±12 0 V.A.C. V.A.C. 120±12 0 V.A.C 4 V.A.C 5 120±12 V.A.C.