MLG-45PDB Installation Manual
Stack Dryer
RETAIN THESE
INSTRUCTIONS IN A
SAFE PLACE FOR
FUTURE REFERENCE
Part No. 113489-5 (W10185535)
ページ2に含まれる内容の要旨
Dryer Safety Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. ! These words mean: You can be killed or seriously injured if you don’t immediately !
ページ3に含まれる内容の要旨
WARNING: Gas leaks cannot always be detected by smell. Gas suppliers recommend that you use a gas detector approved by UL or CSA. For more information, contact your gas supplier. If a gas leak is detected, follow the “What to do if you smell gas” instructions. In the State of Massachusetts, the following installation instructions apply: Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts.
ページ4に含まれる内容の要旨
Important Information ________________ Table of Contents ________ IMPORTANT: A means of restraint must be used to prevent straining of the gas supply when the dryer is moved. SPECIFICATIONS ....................................................... 5 An external means of power removal (disconnect device) must be provided by the installer. INSTALLATION PROCEDURES .................................. 6 Location Requirements ........................................... 6 “Caution: Label all wires prior t
ページ5に含まれる内容の要旨
Specifications _______________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) PER POCKET 45 lb 20.41 kg TUMBLER DIAMETER 32-3/4” 83.19 cm TUMBLER DEPTH 30” 76.20 cm TUMBLER VOLUME PER POCKET 14.6 cu ft 413.43 L 0.56 kW TUMBLER/DRIVE MOTOR PER POCKET 3/4 hp BLOWER/FAN MOTOR PER POCKET BLOWER DRIVEN BY TUMBLER MOTOR DOOR OPENING (DIAMETER) 27” 68.58 cm DOOR SILL HEIGHT TOP POCKET / BOTTOM POCKET 50-1/4” / 10-1/4” 127.64 cm / 26.04 cm DRYERS PER 20’/40
ページ6に含まれる内容の要旨
Installation Procedures _______________ Location Requirements _______________ ! ! WARNING WARNING Excessive Weight Hazard Use two or more people and mechanical equipment to lift, move and install dryer. Failure to do so can result in back or other injury. Explosion Hazard Installation should be performed by competent professional Keep flammable materials and vapors, such as in accordance with local, state, and country codes. In the gasoline, away from dryer. absence of these codes, the inst
ページ7に含まれる内容の要旨
Dryer Enclosure Requirements _______ A = 20-inches (50.80 cm) B = 22.5-inches (57.15 cm) A The requirement to allow the dryer door to open completely is 33.5-inches (85.1 cm). B A minimum overhead clearance of 12-inches (30.48 cm) EXAMPLE: For a bank of 4 dryers, 2 unrestricted openings is required. measuring 20-inches by 22.5-inches (50.80 cm by 57.15 cm) C Dryer should be positioned a minimum of 12-inches are acceptable. (30.48 cm) away from the nearest obstruction. 24-inches To compensate f
ページ8に含まれる内容の要旨
As per the National Fuel Gas Code, “Exhaust ducts for type 2 Single Dryer Venting with Transition Piece clothes dryers shall be constructed of sheet metal or other IMPORTANT: For extended ductwork runs, the cross- noncombustible material. Such ducts shall be equivalent in sectional area of the ductwork can only be increased to an strength and corrosion resistance to ducts made of extent. When the ductwork approaches the maximum galvanized sheet steel not less than 26 gauge (0.0195-inches limit
ページ9に含まれる内容の要旨
The illustration below shows the minimum cross-sectional Single Dryer Venting without Transition Piece area for multiple dryer round or square venting. These figures must be increased if the main duct run from the last dryer to where it exhausts to the outdoors is longer than 20 feet (6.09 meters) or has more than 1 elbow in it. Multiple Dryer Venting with 10-Inch (25.4 cm) Diameter 1,200 cfm (33.98 cmm) Exhaust Connections at Common Duct NUMBER OF DRYERS 4 3 2 1 SQ IN 254 200 155 80 MINIMUM CR
ページ10に含まれる内容の要旨
Grounding Electrical Information _________________ A ground (earth) connection must be provided and installed Electrical Requirements in accordance with local, state, and national regulations or All electrical connections must be made by a properly licensed codes of the country of destination. In the absence of these and competent electrician. This is to ensure that the electrical codes, grounding must conform to applicable requirements installation is adequate and conforms to local, state, an
ページ11に含まれる内容の要旨
Insert the wiring from the two 120 volt 15 amp circuits (one for Gas Information _______________________ top tumbler and one for bottom tumbler) into the strain reliefs. Determine the top pocket electrical connections by checking ! WARNING wire label, which will be marked “top”. Connect wiring from 120 volt 15 amp circuit to top pocket wiring as described in the following illustration (black to black, white to white and green to chassis ground wire). Connect wiring from 120 volt 15 amp circuit
ページ12に含まれる内容の要旨
The input ratings shown on the data label are for elevations TYPICAL NATURAL GAS INSTALLATION up to 2,000 feet (610 meters), unless elevation requirements of over 2,000 feet (610 meters) were specified at the time the dryer order was placed with the factory. The adjustment or conversion of dryers in the field for elevations over 2,000 feet (610 meters) is made by changing each burner orifice. If this conversion is necessary, contact the distributor who sold the dryer or contact the manufacture
ページ13に含まれる内容の要旨
Preoperational Test ___________________ Shutdown Instructions ________________ All dryers are thoroughly tested and inspected before leaving If the dryer is to be shutdown (taken out of service) for a the factory. However, a preoperational test should be period of time, the following must be performed: performed before the dryer is publicly used. It is possible Discontinue power to the dryer either at the external disconnect that adjustments have changed in transit or due to marginal switch or
ページ14に含まれる内容の要旨
Suggested Cleaning Schedule Adjustments 7 Days After Installation ! and Every 12 Months Thereafter WARNING Inspect bolts, nuts, screws, setscrews, grounding connections and nonpermanent gas connections (unions, shutoff valves, and orifices). Belts should be examined. Cracked or seriously frayed belts should be replaced. Complete an operational check of controls and valves. Complete an operational check of all safety devices (lint door/ drawer switch, door switches, sail switch, and hi-limit E