ページ1に含まれる内容の要旨
73113
NO:
ISSUED: June 7, 2004
REVISED: June 15, 2005
HOSHIZAKI
MODULAR FLAKER
MODEL
F-801MAH/-C
F-801MWH/-C
SERVICE MANUAL
ページ2に含まれる内容の要旨
IMPORTANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker. Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department fo
ページ3に含まれる内容の要旨
Please review this manual. It should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should service and maintain the icemaker. This manual should be made available to the technician prior to service or maintenance. CONTENTS I. Specification ...................................................................................................................... 5 1. Icemaker ..............................................
ページ4に含まれる内容の要旨
5. Removal and Replacement of Expansion Valve......................................................... 43 6. Removal and Replacement of Water Regulating Valve (water-cooled model only) .... 44 7. Removal and Replacement of Evaporator Assembly ................................................. 45 8. Removal and Replacement of Fan Motor ................................................................... 49 9. Removal and Replacement of Control Water Valve ...........................................
ページ5に含まれる内容の要旨
I. Specification 1. Icemaker F-801MAH AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 9.4 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP FAN MOTOR 115 V 0.85 FLA 1/15 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 * 823 (373) 786 (357) 748 (339) Reference without *marks 80 711 (323) 677 (307) 64
ページ6に含まれる内容の要旨
F-801MWH AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 8.5 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 * 720 (327) 693 (315) 677 (307) Reference without *marks 80 661 (300) 646 (293) 630 (286) 90 616 (279) * 605 (274) 587 (266) 100 573 (260) 560 (
ページ7に含まれる内容の要旨
F-801MAH-C AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 9.4 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP FAN MOTOR 115 V 0.85 FLA 1/15 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 * 752 (341) 728 (330) 688 (312) Reference without *marks 80 650 (295) 614 (279) 580 (263) 90 548 (249) * 552
ページ8に含まれる内容の要旨
F-801MWH-C AC SUPPLY VOLTAGE 115/60/1 COMPRESSOR 120 V 8.5 RLA 51 LRA GEAR MOTOR 120 V 3 FLA 1/4 HP OTHER 120 V 0.03 A MAXIMUM FUSE SIZE 20 A MAX. HACR BREAKER (USA ONLY) 20 A MAX. CIRC. BREAKER (CANADA ONLY) 20 A MINIMUM CIRCUIT AMPACITY 20 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 * 645 (293) 620 (281) 608 (276) Reference without *marks 80 596 (270) 585 (265) 574 (260) 90 563 (255) * 550 (249) 541 (246) 100 531 (241) 521
ページ9に含まれる内容の要旨
II. General Information 1. Construction F-801MAH/-C Water Supply Control Water Valve Inlet Bin Control Junction Box Ice Chute Condenser Evaporator Fan Motor Expansion Valve Compressor Flush Water Valve Drier Control Box Gear Motor 9
ページ10に含まれる内容の要旨
F-801MWH/-C Water Supply Control Water Valve Inlet Bin Control Junction Box Ice Chute Water Evaporator Regulator Expansion Valve Compressor Flush Water Valve Drier Control Box Gear Motor 10
ページ11に含まれる内容の要旨
2. Control Box Layout F-801MAH/-C WATER CONTROL RELAY FLUSH TIMER TRANSFORMER GEAR MOTOR RELAY FLUSH CONNECTOR CIRCUIT PROTECT FLUSH RELAY GEAR SWITCH MOTOR CAP. ICE FAN MOTOR PRESSURE SWITCH CAP POWER SWITCH GEAR MOTOR PROTECT RELAY STARTER FUSE START FUSE CAPACITOR (GEAR MOTOR) RUN CONTROL CAPACITOR TIMER Note: The above component names are identical with the wiring label, but not with the parts list. 11
ページ12に含まれる内容の要旨
F-801MWH/-C
12
ページ13に含まれる内容の要旨
III. Technical Information 1. Water Circuit and Refrigeration Circuit F-801MAH/-C 13
ページ14に含まれる内容の要旨
F-801MWH/-C 14
ページ15に含まれる内容の要旨
2. Wiring Diagrams F-801MAH/-C, F-801MWH/-C 15
ページ16に含まれる内容の要旨
3. Sequence of Electrical Circuit [a] When power switch is moved to “ON” position and flush switch to “ICE” position, water starts to be supplied to reservoir. 16
ページ17に含まれる内容の要旨
[b] When reservoir has been filled, gear motor starts immediately. 17
ページ18に含まれる内容の要旨
[c] Compressor starts about 60 sec. after gear motor starts. 18
ページ19に含まれる内容の要旨
[d] Bin control operates, and about 6 sec. later, compressor and gear motor stop simultaneously. 19
ページ20に含まれる内容の要旨
[e] Low water (except water-cooled model). 20