ページ1に含まれる内容の要旨
73075
NO:
ISSUED: JAN. 20, 1999
DEC. 17, 2003
REVISED:
HOSHIZAKI
MODULAR FLAKER
MODEL
F-1000MAF/-C
F-1000MWF/-C
F-1000MRF/-C
F-1000MLF/-C
SERVICE MANUAL
ページ2に含まれる内容の要旨
IMPORTANT Only qualified service technicians should attempt to service or maintain this icemaker. No service or maintenance should be undertaken until the technician has thoroughly read this Service Manual. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker. Should the reader have any questions or concerns which have not been satisfactorily addressed, please call or write to the HOSHIZAKI Technical Support Department fo
ページ3に含まれる内容の要旨
Please review this manual. It should be read carefully before the icemaker is serviced or maintenance operations are performed. Only qualified service technicians should service and maintain the icemaker. This manual should be made available to the technician prior to service or maintenance. CONTENTS PAGE I. SPECIFICATIONS .................................................................................................... 5 1. ICEMAKER ..........................................................
ページ4に含まれる内容の要旨
F-1000MWF ......................................................................................................... 42 F-1000MRF .......................................................................................................... 43 F-1000MLF ........................................................................................................... 44 F-1000MAF-C....................................................................................................... 45 F-1000MWF-C...........
ページ5に含まれる内容の要旨
I. SPECIFICATION 1. ICEMAKER F-1000MAF AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 1.6 FLA 1/6 HP FAN MOTOR 115 V 0.85FLA 1/15 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *970 (440) 930 (422) 890 (404) Reference with
ページ6に含まれる内容の要旨
F-1000MWF AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 1.6 FLA 1/6 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *890 (404) 855 (389) 840 (380) Reference without *marks 80 820 (372) 805 (364) 785 (356) 90 770 (349) *755
ページ7に含まれる内容の要旨
F-1000MRF AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 1.6 FLA 1/6 HP FAN MOTOR REMOTE 120 V 3 A MAX OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *930 (422) 895 (407) 865 (393) Reference without *marks 80 835
ページ8に含まれる内容の要旨
F-1000MLF AC SUPPLY VOLTAGE 115/60/1 GEAR MOTOR 120 V 1.6 FLA 1/6 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (F) PER 24 HR. Temp. (F) 50 70 90 lbs./day ( kg/day ) 70 1150 (522) 1035 (469) 1005 (456) This data is for reference only, 80 980 (444) 950 (431) 925 (420) different condensing unit will vary data. 90 900 (408) 885 (401) 850 (386) 100 83
ページ9に含まれる内容の要旨
F-1000MAF-C AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 1.6 FLA 1/6 HP FAN MOTOR 115 V 0.85FLA 1/15 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *860 (390) 820 (373) 790 (359) Reference without *marks 80 765 (346) 735
ページ10に含まれる内容の要旨
F-1000MWF-C AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 1.6 FLA 1/6 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 50 70 90 lbs./day ( kg/day ) 70 *790 (358) 760 (346) 750 (340) Reference without *marks 80 735 (333) 720 (327) 710 (322) 90 695 (316) *68
ページ11に含まれる内容の要旨
F-1000MRF-C AC SUPPLY VOLTAGE 208-230/60/1 (3 wire with neutral for 115V) COMPRESSOR 240 V 4.2 RLA 34 LRA GEAR MOTOR 120 V 1.6 FLA 1/6 HP FAN MOTOR REMOTE 120 V 3A MAX OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (°F) PER 24 HR. Temp.(°F) 507090 lbs./day ( kg/day ) 70 *840 (381) 810 (368) 790 (358) Reference without *marks 80 765 (347) 745 (337
ページ12に含まれる内容の要旨
F-1000MLF-C AC SUPPLY VOLTAGE 115/60/1 GEAR MOTOR 120 V 1.6 FLA 1/6 HP OTHER 120 V 0.03A MAXIMUM FUSE SIZE 15 A MAX. HACR BREAKER (USA ONLY) 15 A MAX. CIRC. BREAKER (CANADA ONLY) 15 A MINIMUM CIRCUIT AMPACITY 15 A APPROXIMATE ICE PRODUCTION Ambient WATER TEMP. (F) PER 24 HR. Temp. (F) 50 70 90 lbs./day ( kg/day ) 70 1020 (463) 945 (428) 915 (415) This data is for reference only, 80 885 (402) 860 (390) 835 (378) different condensing unit will vary data. 90 805 (366) 795 (361) 760 (344) 100 7
ページ13に含まれる内容の要旨
2. CONDENSER UNIT URC-6F 13
ページ14に含まれる内容の要旨
SPECIFICATIONS MODEL: URC-6F EXTERIOR Galvanized Steel DIMENSIONS (W x D x H) 21-15/16" x 15-11/16" x 17-7/8" (557 x 398 x 454 mm) REFRIGERANT CHARGE R404A 1 lb. 14 oz. (850 g) WEIGHT Net 61 lbs. (28 kg) Shipping 68 lbs. (31 kg) CONNECTIONS REFRIGERANT One Shot Couplings (Aeroquip) ELECTRICAL Permanent Connection CONDENSER Air-cooled HEAD PRESSURE CONTROL Condensing Pressure Regulator AMBIENT CONDITION Min. -20°F - Max. +122°F (-29°C to +50°C) Outdoor use 14
ページ15に含まれる内容の要旨
II. GENERAL INFORMATION 1. CONSTRUCTION F-1000MAF/-C Water Supply Control Water Valve Inlet Bin Control Junction Box Ice Chute Condenser Evaporator Fan Motor Expansion Valve Compressor Flush Water Valve Drier Control Box Gear Motor 15
ページ16に含まれる内容の要旨
F-1000MWF/-C Water Supply Control Water Valve Inlet Bin Control Junction Box Ice Chute Water Evaporator Regulator Expansion Valve Compressor Flush Water Valve Drier Control Box Gear Motor 16
ページ17に含まれる内容の要旨
F-1000MRF/-C Water Supply Control Water Valve Inlet Bin Control Junction Box Ice Chute Evaporator Compressor Expansion Valve Receiver Tank Flush Water Valve Control Box Drier Gear Motor 17
ページ18に含まれる内容の要旨
F-1000MLF/-C Water Supply Control Water Valve Inlet Bin Control Junction Box Ice Chute Hot Gas Evaporator Valve Expansion Valve Solenoid Valve Flush Water Valve Heat Control Box Exchanger Gear Motor 18
ページ19に含まれる内容の要旨
2. CONTROL BOX LAYOUT F-1000MAF/-C WATER CONTROL RELAY FLUSH TIMER TRANSFORMER GEAR MOTOR RELAY FLUSH CONNECTOR CIRCUIT PROTECT FLUSH RELAY GEAR SWITCH MOTOR CAP. ICE FAN MOTOR PRESSURE SWITCH CAP POWER SWITCH GEAR MOTOR PROTECT RELAY STARTER FUSE START FUSE CAPACITOR (GEAR MOTOR) RUN CONTROL CAPACITOR TIMER Note: The above component names are identical with the Wiring Label, but not with the Parts List. 19
ページ20に含まれる内容の要旨
F-1000MWF, F-1000MRF/-C
20