ページ1に含まれる内容の要旨
HGFD45
HOBART HGF, HGD AND HGC SERIES
GAS FRYERS
WITH OR WITHOUT FILTER-IN-A-DRAWER
MODELS
HGF35 ML-126994 HGF35F ML-135536
HGF45 ML-126995 HGF45F ML-135537
HGF65 ML-126996 HGF65F ML-135538
HGF85 ML-126997
HGF85F ML-135539
HGFD35 ML-126416
HGD35F ML-126953
HGFD45 ML-126417 HGD45F ML-126956
HGFD65 ML-126418 HGD65F ML-126959
HGFD85 ML-126419 HGD85F ML-126962
HGFC35 ML-126420 HGC35F ML-126954
HGFC45 ML-126421 HGC45F ML-126957
HGFC65 ML-126422
HGC65F ML-126960
HGFC85 ML-126423
HGC85F ML-126963
701 S
ページ2に含まれる内容の要旨
IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER. IMPORTANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS AT MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS
ページ3に含まれる内容の要旨
TABLE OF CONTENTS GENERAL ............................................................................................................................................ 5 SPECIFICATIONS......................................................................................................................... 5 OPTIONS AND FEATURES......................................................................................................... 6 BATTERY CONFIGURATIONS ..........................................
ページ4に含まれる内容の要旨
TABLE OF CONTENTS (cont.) HGFC SERIES .................................................................................................................................. 21 CONTROLS ................................................................................................................................. 21 PROGRAMMING ......................................................................................................................... 22 TEMPERATURE AND TIME PROGRAMMING ................
ページ5に含まれる内容の要旨
Installation, Operation and Care of MODELS HGF, HGD and HGC SERIES GAS FRYERS SAVE THESE INSTRUCTIONS GENERAL Hobart HGF, HGD and HGC Series Gas Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance of your fryer will result in many years of satisfactory performance. It is suggested that you thoroughly read this entire manual and carefully follow all of the instructions provided. The Mobile Filter, used for filter-ready fryers, is covered in a sepa
ページ6に含まれる内容の要旨
OPTIONS AND FEATURES • Stainless Steel Tank (Standard) • Basket Lift with Timer (D and C series) • Tri-, Twin- or Single-Basket (D and C series) • Manual Pilot or Electronic Ignition (D and C series) • Filter-Ready (Stand-alone fryers only) • Filter-In-A-Drawer (Model numbers ending in F) BATTERY CONFIGURATIONS • Batteries can be configured with any HGF, HGD or HGC Series Fryer or Frymate Dump Station; only one Frymate Dump Station per battery (Fig. 1). • All fryers can be free-standing or arran
ページ7に含まれる内容の要旨
3 Cabinets in Battery Fryer Fryer Fryer Fryer Fryer Dump Fryer Dump Fryer C AB AB C A BC Filter Filter Filter Dump Fryer Fryer A B C Filter 4 Cabinets in Battery (For 35 and 45 Only) Fryer Fryer Fryer Fryer Dump Fryer Fryer Fryer AB C D AB C D Filter Filter Fryer Dump Fryer Fryer Fryer Fryer Dump Fryer AB C D AB C D Filter Filter Fryer Fryer Fryer Dump AB C D Filter The configurations shown are standard (default) locations. Any deviati
ページ8に含まれる内容の要旨
FIELD-INSTALLED ACCESSORIES FACTORY-INSTALLED OPTIONS • Casters • Basket Lift • Twin Baskets • Battery Configuration • Tri-Baskets (65 and 85 models only) • Battery Interplumbing (Model numbers ending in F) • Single Baskets • Electronic Ignition • Heat Lamp (RO only) • Flex Hose 4' (1.2 m) (gas connection) • Flex hose S/S 5' (1.5 m) (gas connection) • Vat Cover • Battery Tray • Tank Skimmer • Tank Scoop HGF SERIES FRYMATE (Dump Station) 1 Model HGFO Frymate Dump Station can be configured in a ba
ページ9に含まれる内容の要旨
INSTALLATION Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Ensure the fryer is configured for the proper elevation. UNPACKING This fryer was carefully inspected before leaving the factory. The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment. Immediately after unpacking the fryer, check for possible shipping
ページ10に含まれる内容の要旨
LOCATION The equipment area must be kept free and clear of combustible substances. Minimum clearance from combustible construction is 6" (15 cm) from the sides and 6" (15 cm) from the back of the fryer. Minimum clearance from noncombustible construction is 0" from the sides and 0" from the back. At least 16" (41 cm) clearance must be between the fryer and any open-top flame units. Adequate clearances for servicing and proper operation must be allowed. The fryer may be installed on combustible fl
ページ11に含まれる内容の要旨
ASSEMBLY When installed, the fryer must be restrained to prevent tipping to avoid the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances or installing the fryer in an alcove, or by separate means, such as adequate ties. Fryers Mounted on Legs (Non-Batteried Fryers) Fryers serviced from the rear must have a minimum clearance of 18" (46 cm) from the wall when mounted on legs. 1. Position fryer in an open space near the f
ページ12に含まれる内容の要旨
GAS CONNECTIONS CAUTION: All gas supply connections and any pipe joint compound must be resistant to the action of propane gases. The gas inlet is located on the lower right rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer. 1 1 The gas supply line must be at least the equivalent of /2" iron pipe for single units and 1 /4" for batteries. 3 1 If using the optional quick-disconnect flex hose: /4" iron pipe for single units and 1 /4" iron pipe
ページ13に含まれる内容の要旨
LEVELING FRYER 1. Place a spirit level on top of the fryer after gas connections have been made. 2. Adjust the legs to ensure that the fryer is level front-to-back and side-to side in the final installed position. FLUE CONNECTIONS The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must extend 6" (15 cm) beyond fryer sides. Adequate ventilation must be provided and comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96 (latest edition),
ページ14に含まれる内容の要旨
OPERATION WARNING: HOT OIL AND PARTS CAN CAUSE BURNS. USE CARE WHEN OPERATING, CLEANING AND SERVICING THE FRYER. WARNING: SPILLING HOT FRYING COMPOUND CAN CAUSE SEVERE BURNS. DO NOT MOVE FRYER WITHOUT DRAINING ALL FRYING COMPOUND FROM THE TANK. BEFORE FIRST USE • Clean the protective metal oils from all surface parts and the tank interior using a noncorrosive, grease-dissolving commercial cleaner. Follow the cleaner manufacturer's directions. • Rinse thoroughly and drain (open the front door to
ページ15に含まれる内容の要旨
LIGHTING INSTRUCTIONS FOR HGF FRYER WITH MANUAL PILOT IGNITION NOTE: HGF fryer is only available with manual ignition. CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1. Turn the thermostat OFF. The thermostat is located behind the door (Fig. 5). 2. Push the gas control valve knob and turn to OFF (Fig. 6). Wait 5 minutes for unburned gas to vent. 3. Push and turn gas control valve on to the "I" in PILOT (Fig. 6). 4. While still holding the kn
ページ16に含まれる内容の要旨
LIGHTING INSTRUCTIONS FOR MANUAL PILOT IGNITION (HGFD & HGFC(F) SERIES) CAUTION: Before turning the burners on, the fry tank must be filled with liquid or melted shortening. 1. Turn the thermostat knob (located behind the door panel) to OFF (Fig. 7). 2. Push the gas valve extension arm in and turn arm to OFF. Wait 5 minutes for unburned gas to vent. 3. Push gas valve extension arm in and turn to PILOT. 4. While still depressing the arm, light the pilot with a lit taper. Continue with steps 2 thr
ページ17に含まれる内容の要旨
HGFD(F) SERIES CONTROLS HGFD(F) Series Fryers are equipped with digital controls and a solid state thermostat. Control Guide CONTROL DESCRIPTION Power switch; for turning the fryer on or off. For cleaning purposes when the fryer is filled with water. Tem- perature is maintained at approximately 192°F (89°C). For entering and exiting the program mode. For scrolling through program parameters. Raises and lowers left fry basket (optional). Starts and stops the timer. Silences the alarm after the ti
ページ18に含まれる内容の要旨
PROGRAMMING Temperature, time, energy source and other parameters must be set before operating. Once these parameters are set, the fryer can be operated at the touch of a button. Press to enter the program mode and scroll through the parameters. If the Parameter Lock feature is on, LoC is displayed in the window and program entry cannot be accessed. To access the program mode while LoC is on, press within 6 seconds of pressing . To turn the Parameter UP UP Lock feature off, see Program Gu
ページ19に含まれる内容の要旨
Melt Options (HGD Series) When using solid shortening in the fryer, the CY S (solid shortening) option must be used. Solid shortening must be gently warmed to a liquid state before heating to frying temperatures. Melting solid shortening without using this option will damage the fry tank and scorch the shortening. The controller has three options for bring shortening up to temperature: *CY L (Liquid shortening) - For slowly bringing liquid shortening up to temperature. CY S (Solid shortening) -
ページ20に含まれる内容の要旨
USING THE FRYER (After Startup) Models Without Basket Lift Option 1. Load the fry basket(s); do not overfill. See Recommended Basket Capacities on page 30. 2. Carefully lower basket(s) into shortening. 3. Press to start the left timer. Press to start the right timer. to silence the left timer beeper. Press 4. When the timer times out, a beeper sounds. Press to silence the right timer beeper. 5. Remove cooked product from fryer. Models With Basket Lift Option 1. Place the fry basket(s) on t