Super Runner Series Gas Fryers
Installation & Operation Manual
Series SR42, SR52 & SR62
NON-CE &
For Service, Call (318) 865-1711
Price: $10.00
Dean, 8700 Line Avenue, PO Box 51000,
PRINTED IN THE
UNITED STATES Shreveport, Louisiana 71135-1000
819-5999
Shipping Address: 8700 Line Avenue,
JULY 2005
Shreveport, Louisiana 71106
ページ2に含まれる内容の要旨
NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster/DEAN Factory Authorized Service Center (FASC) or other qualified professional should perform installation, maintenance, and repairs. Installation, maintenance, or repairs by unqualified personnel may void the manufacturer’s warranty. NOTICE This equipment must be installed in accordance with the appropriate national and local codes of the country and/or region
ページ3に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS 1.1 Safety Information Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout this manual you will find notations enclosed in double-bordered boxes with the symbol . The information contained in the box concerns actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system to malfunction. 1.2 General Install
ページ4に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position. Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not function efficiently. Super Runner Series gas fryers cannot be curb mounted and must be equipped with either legs or casters provided. A. Adjust leg height with an adj
ページ5に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS AUSTRALIAN REQUIREMENTS: To be installed in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any other relevant statutory regulations. CE UNITS ONLY: Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings and Pilot Markings are listed in the table below: NOMINAL MANIFOLD GAS PRESSURE HEAT INPUT- ORIFICE ORIFICE BURNER P
ページ6に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS DANGER A manual shut-off valve must be installed in the gas supply (service) line upstream of this appliance and in a position where it can be reached quickly in the event of an emergency. DANGER The fryer must be connected to the gas supply specified on the rating and serial number plate located on the inside of the appliance door. DO NOT ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS NOT CONFIGUR
ページ7に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS When converting from G20 (or G25) gas to G31 propane (or vice-versa), the following procedures apply: ♦ Burner orifices and pilot orifice MUST be replaced. ♦ Adjust orifice gas pressure to the appropriate value listed in the table on page 1-3 by turning the gas-valve adjustment screw. ♦ After adjustment, replace the adjustment-screw cover. ♦ Affix the new label included with the conversion kit next the existing
ページ8に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 1: INSTALLATION INSTRUCTIONS Frypot Assembly 1/2—3/4 Reducer Manifold Support Bracket Bushing Gas Valve Gas Burner Burner See Detail A 1.63-inch [41-mm] Orifice 1.30-inch [33-mm] Pressure Test Gas Manifold Spigot Orifice Gas Manifold Assembly Detail A Burner/Orifice Location Temperature Control Typical gas valve, burner and orifice locations (SR42 shown above). Propane Applications: 1.6 Gas Conversion Components Proper Regulator Must
ページ9に含まれる内容の要旨
ページ10に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 2: OPERATION 5. Fill the frypot with oil, shortening or water to the bottom OIL LEVEL line scribed on the frypot back. Ensure heating tubes are covered in liquid prior to engaging burners. NOTE: If solid shortening is used, pack the shortening into the frypot, ensuring the shortening is packed beneath, between and above the tubes prior to operating fryer. 6. Open the manual shut-off valve on the incoming gas supply line and rotate the gas v
ページ11に含まれる内容の要旨
SUPER RUNNER SERIES GAS FRYERS CHAPTER 2: OPERATION DANGER "Dry-firing" the fryer will cause damage to the frypot and can cause a fire. Always ensure that shortening, cooking oil or water covers the burner tubes before lighting the burners. 2. With the pilot lit, push down and slowly turn the gas valve knob to the ON position. 3. Rotate the operating thermostat knob to the desired frying temperature. The burner should light and burn with a strong blue flame. DANGER If t
ページ12に含まれる内容の要旨
300 350 ON 4 0 0 SUPER RUNNER SERIES GAS FRYERS CHAPTER 2: OPERATION 2.5 Wiring Diagram CE UNITS ONLY: WARNING DO NOT CONNECT ANY EXTERNAL ELECTRICAL POWER TO THIS UNIT TH PP TH PP THERMOPILE HONEYWELL 807-3565 OPERATING THERMOSTAT COAXIAL LEAD TO THERMOCOUPLE 812-1284 HIGH-LIMIT HONEYWELL CE NON-CE UNITS ONLY: CONTROL CIRCUIT PILOT GENERATOR 3C 4C 1/2 P.S.I. HONEYWELL 1C 2C OFF HIGH-LIMIT COM N/O N/C OPERATING THERMOSTAT 2-4 HONEYWELL 1/2 P.S.I. 200 250 C P
ページ13に含まれる内容の要旨
THIS PAGE INTENTIONALLY LEFT BLANK.
ページ14に含まれる内容の要旨
Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135 Price: $10.00 PRINTED IN THE UNITED STATES 819-5999 JULY 05