ページ1に含まれる内容の要旨
INSTALLATION INSTRUCTIONS
Instrucciones de instalación Istruzioni di installazione
Installationsanleitung Installatie-instructies
Instruções de Instalação Instructions d´installation
Automated Flat Panel Ceiling Lift
This device complies with part 15 of the FCC rules. Operation is subject to the following 2 conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This equi
ページ2に含まれる内容の要旨
CM2C40 Installation Instructions CSAV, Inc., and its affiliated corporations and subsidiaries (collectively, "CSAV"), intend to make this manual accurate and complete. However, CSAV makes no claim that the information contained herein covers all details, conditions or variations, nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change without notice or obligation of any kind. CS
ページ3に含まれる内容の要旨
Installation Instructions CM2C40 CONTENTS INSTALLATION REQUIREMENTS ..............................................................................................................5 Power Requirements and Wiring ...............................................................................................................5 INSTALLATION ............................................................................................................................................5 Pre-Installation Confi
ページ4に含まれる内容の要旨
CM2C40 Installation Instructions LEGEND Tighten Fastener Pencil Mark Apretar elemento de fijación Marcar con lápiz Befestigungsteil festziehen Stiftmarkierung Apertar fixador Marcar com lápis Serrare il fissaggio Segno a matita Bevestiging vastdraaien Potloodmerkteken Serrez les fixations Marquage au crayon Loosen Fastener Drill Hole Aflojar elemento de fijación Perforar Befestigungsteil lösen Bohrloch Desapertar fixador Fazer furo Allentare il fissaggio Praticare un foro Bevestiging losdraaien
ページ5に含まれる内容の要旨
Installation Instructions CM2C40 1. Install interface bracket or mounting buttons to display INSTALLATION REQUIREMENTS following the instructions provided with bracket. The CM2C40 has been designed to be mounted either hanging 2. Measure the distance from the center of a bottom mounting from an overhead structure or mounted to existing stud wall button to the lowest point of the display. structures. 3. Record measurement. WARNING: IMPROPER INSTALLATION CAN LEAD TO LIFT TIPPING CAUSING SEVERE PER
ページ6に含まれる内容の要旨
CM2C40 Installation Instructions 6 10 10 6 x2 9 Figure 5 10. Using the remote control, lower the lift until it stops. 5 (See figure 3) 4 If more than 2" of faceplate adjustment is required: 11. Raise lift following instructions in step 6. (See figure 3) 12. Loosen four nuts securing faceplate mounting bracket to Figure 3 frame. (See figure 6) 7. Remove two locknuts securing faceplate to faceplate 13. Move faceplate mounting bracket desired amount. mounting bracket. (See figure 4) (See figure 6)
ページ7に含まれる内容の要旨
Installation Instructions CM2C40 15. Align studs in faceplate with appropriate holes in faceplate mounting bracket and hang faceplate on bracket with studs. 16. Secure faceplate to faceplate mounting bracket using two locknuts. (See figure 7) 1 x2 x2 16 Figure 7 Cable Installation and Routing The CM2C40 has an integrated cable management system that allows cables to be automatically "fed out" as the lift raises, and Cable Guide "reeled in" as the lift lowers while maintaining constant cable Side
ページ8に含まれる内容の要旨
CM2C40 Installation Instructions 4 From Display x1 5 5 6 8 4 x3 8 4 x2 7 7 9 9 10 10 Figure 10 8
ページ9に含まれる内容の要旨
Installation Instructions CM2C40 6. Route cable(s) down through opening at rear of middle 13. Slide cable guide side cover over cable guide making cable clamp mounting bracket. (See figure 10) and certain lip on back cover plate is fully seated in groove in (See figure 11) cable guide side cover. (See figure 12) NOTE: If plug on cable will not fit through opening loosen or remove one screw securing middle cable clamp Back Cover Plate mounting bracket to mount frame and pivot middle cable clamp m
ページ10に含まれる内容の要旨
CM2C40 Installation Instructions of travel must be considered when location the mount Mount Installation and a stop bar must be installed along the top edge of The CM2C40 has been designed to be mounted either hanging the opening in the ceiling. The stop bar must span the from an overhead structure or mounted to existing stud wall entire width of the front and back openings, and structures. The following instructions assume a suitable protrude outward into the opening a minimum of 1/2". mounting
ページ11に含まれる内容の要旨
Installation Instructions CM2C40 7. While maintaining dimensions referenced in figure 15, mark Display Installation base plate mounting hole locations. (See figure 16) 8. Drill pilot holes at marked locations. WARNING: EXCEEDING MAXIMUM WEIGHT CAPACITY 9. Mark four side bracket mounting hole locations if applicable. (See figure 16) CAN LEAD TO SERIOUS PERSONAL INJURY OR AMAGE 10. Drill four pilot holes at marked locations. TO EQUIPMENT! It is the installers responsability to ensure the total am
ページ12に含まれる内容の要旨
CM2C40 Installation Instructions NOTE: Holes are provided in the faceplate for use with a padlock or similar locking device, if desired. In addition, WARNING: IMPROPER INSTALLATION CAN LEAD TO the pin and nut may be removed from the upper holes SEVERE PERSONAL INJURY OR DAMAGE TO and moved to the lower holes for use as a more EQUIPMENT! Make sure all four nuts are tight before permanent locking device. (See figure 19) continuing installation! Display removed for clarity Remove pin 1 and nuts and
ページ13に含まれる内容の要旨
Installation Instructions CM2C40 2. If the dimension identified during step 1 above is equal to or Bottom Cover Installation less than the thickness of the bottom cover being installed, After the CM2C40 has been properly configured for the display the display travel limits must be adjusted before continuing and the display installed, the bottom cover height must be to aviod a collision scenario between the bottom cover and adjusted to ensure proper fit into ceiling. the ceiling. Refer to step 6
ページ14に含まれる内容の要旨
CM2C40 Installation Instructions 5. Assemble bottom cover to cover mounting plate using There is an upward travel limit adjustment screw and a #10-24 screws a minimum of 1/4" plus the thickness of the downward travel limit adjustment screw located on the top right cover material long. (not provided). (See figure 25) hand side of the mount. (See figure 27) NOTE: 10 full turns of the "Extend" or "Retract" travel adjustment screws is equal to 1" of display travel. 6. Turning the "Extend" travel a
ページ15に含まれる内容の要旨
Installation Instructions CM2C40 Lift Column Bearing Adjustment The upper and lower lift columns are aligned using two lift bearings, one upper and one lower. Bearing adjustment is pre-set at the factory, however, there may be times when it is required to make slight adjustments in bearing tightness to eliminate excess play in lift columns or noise. WARNING: OVERTENSIONING CAN LEAD TO DAMAGE Upper Lift Column Bearing Adjustment Points TO EQUIPMENT! DO NOT overadjust! (Located on back side) IMPOR
ページ16に含まれる内容の要旨
CM2C40 Installation Instructions Normal Operating Mode Extended Programming Capabilities The CM2C40 allows for extended programming to make the KEY FUNCTION REQUIRED ACTION mount compatible with other devices such as a Universal 1 MOVE DISPLAY TO HOME PRESS ONCE Remote or other control devices through a serial connection. 2 RETRACT DISPLAY PRESS ONCE Setting or changing the configuration of the CM2C40 is done 3 NOT USED N/A through the remote control provided with the mount. 4 NOT USED N/A The r
ページ17に含まれる内容の要旨
Installation Instructions CM2C40 NEC Protocol: Table 1-1: IR System Code The modulated carrier is usually derived from 455kHz and is 1/12 of the frequency with 1/3 duty cycle. Switch # 2 Switch # 1 Switch # 3 Custom Code When data are transmitted repeatedly, the frame cycle is 107.9ms or 186 period. Off Off Off 6E A frame consists of a syn pulse, an eight-bit custom code, an On Off Off E1 eight-bit inverted custom code, an eight-bit data code and an Off E2 Off On eight-bit inverted data code. O
ページ18に含まれる内容の要旨
CM2C40 Installation Instructions IR-SE15 Programming IR-SE15 Control Features: Carrier Frequency:38KHz Protocol:NEC - Full Repeat System Code(s):6E (Default) - Multiple Codes Selected via Key-Press (see below) Table 1-2: IR-SE15 Control Codes Key Number Key Name Hex Code 1 HOME 02 2 SAVE 1A 3 UP 07 4 LEFT 09 5 STOP 0A 6 RIGHT 0B 7 DOWN 0D 8 PRESET 1 12 10 PRESET 2 13 12 PRESET 3 14 To Change System Code: 1. Press and Release Key 3 + 7 (Enter Setup Mode) 2. Press and Release Key 8 3. Press
ページ19に含まれる内容の要旨
Installation Instructions CM2C40 IR-SC33a Programming IR-SC33a Control Features Carrier Frequency: 38KHz Protocol: NEC - Full Repeat System Code: 6E Table 1-4: Key Number Key Name Hex Code 3 HOME 02 8 RETRACT 07 10 LEFT 09 12 RIGHT 0B 14 EXTEND 0D 19 PRESET 1 12 20 PRESET 2 13 21 PRESET 3 14 27 SAVE 1A 3 8 12 10 14 20 19 21 27 19
ページ20に含まれる内容の要旨
CM2C40 Installation Instructions Serial Communications NOTE: Check with the appropriate automation system vendor for available drivers and/or software for any external devices. Notes: [PR] = Product ID (CM2C40 = 02) [AD] = Address (see address description & table) [CR] = ASCII Carriage Return [CH] = Check Code [ST] = Status (see status table) Connecctions to be made to 9 pin connector as follows: RS-485 REF Pin 7 RS-485 + Pin 8 RS-485 - Pin 9 Communication parameters as specified in ANSI TIA/EIA