ページ1に含まれる内容の要旨
Installation
1 C I2 N R 3U H
C IN AR
1 2 3
C IN C IN R U AH R
S TE EL M EP T O SE T P STS T
S TE EL M EP T O SE T P STS T
H TIE G M HP START L TO EM WP H TIE GM HP START L TO EM WP
M TE E M DP H NE O AT M TE E M DP H NE O AT
C C
25 25
Drying Tumblers
Stacked 30 Pound Capacity
Stacked 45 Pound Capacity
Starting Serial No. 0602004144
Refer to Page 4 for Model Identification
NOTA: Para bajar una
copia de estas
instrucciones en
español, visite
www.comlaundry.com.
T477C
T477C
Keep These Instruc
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
Installation must conform with local codes or in the absence of local codes with: In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.” In Canada, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I. In Australia, installation must comply with the Austr
ページ4に含まれる内容の要旨
Introduction......................................................................................... 4 Table of Model Identification ............................................................................. 4 Customer Service.................................................................................. 5 Contents Wiring Diagram.................................................................................... 5 Serial Plate Location.....................................................
ページ5に含まれる内容の要旨
Single Drop Timer .............................................................................. 46 Power-Up Mode.................................................................................... 46 Ready Mode.......................................................................................... 46 Start Mode ............................................................................................ 46 Run Mode ...............................................................................
ページ6に含まれる内容の要旨
Introduction Model Identification Information in this manual is applicable to these models: Gas Steam Electric CHD30STG2-CAT30L IPD30STG2-ITT30L CHD30STS2-CTT30S CHD30STE2-CTT30E CHD30STG2-CAT30N IPD30STG2-ITT30N CHD30STS2-CUT30S CHD30STE2-CUT30E CHD30STG2-CTT30L MTT30N DRST30S2-BTT30S DRST30E2-BTT30E CHD30STG2-CTT30N NTT30N DRST30S2-BUT30S DRST30E2-BUT30E CHD30STG2-CUT30L SAT30L HTT30S HTT30E CHD30STG2-CUT30N SAT30N HUT30S HUT30E DRST30G2-BAT30L STT30D IPD30STS2-ITT30S IPD30STE2-ITT30E DRST30G2
ページ7に含まれる内容の要旨
Introduction Customer Service Serial Plate Location If literature or replacement parts are required, contact When calling or writing for information about your the source from which the machine was purchased or product, be sure to mention model and serial numbers. contact Alliance Laundry Systems at (920) 748-3950 Model and serial numbers are found on serial plate on for the name and address of the nearest authorized the rear of machine and inside door. parts distributor. For technical assis
ページ8に含まれる内容の要旨
Safety Information Explanation of Safety Messages WARNING Precautionary statements (“DANGER,” “WARNING,” and “CAUTION”), followed by specific instructions, Failure to install, maintain, and/or operate are found in this manual and on machine decals. These this machine according to manufacturer’s precautions are intended for the personal safety of the instructions may result in conditions which operator, user, servicer, and those maintaining the can produce serious injury, death and/or ma
ページ9に含まれる内容の要旨
Safety Information 14. The interior of the tumbler and the exhaust duct Important Safety Instructions should be cleaned periodically by qualified Save These Instructions service personnel. 15. If not installed, operated and maintained in WARNING accordance with the manufacturer’s instructions or if there is damage to or mishandling of this product’s components, use of this product could Hazardous Voltage. Can cause shock, burn expose you to substances in the fuel or from fuel or cause de
ページ10に含まれる内容の要旨
Safety Information 23. Remove laundry immediately after tumbler stops. 29. DO NOT bypass any safety devices. 24. Always read and follow manufacturer’s 30. Solvent vapors from dry-cleaning machines instructions on packages of laundry and cleaning create acids when drawn through the heater of the aids. Heed all warnings or precautions. To reduce drying unit. These acids are corrosive to the the risk of poisoning or chemical burns, keep tumbler as well as to the laundry load being them out of r
ページ11に含まれる内容の要旨
Specifications and Dimensions Specifications T30 T45 66 dBA 67 dBA Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor. 544 673 Net Weight (approximate): (247) (305) Pounds (kg) 30 x 26 33 x 30 Cylinder Size: (762 x 660) (838 x 762) Inches (mm) 2 x 30 2 x 45 Cylinder Capacity (dry weight) (2 x 13.6) (2 x 20.5) Pounds (kg) 1/4 1/2 Drive Motor Horsepower** 1/4 1/2 Fan Motor Horsepower** 50 Hertz 340 N/A (160)
ページ12に含まれる内容の要旨
Specifications and Dimensions Cabinet Dimensions J A B C D E F H G I TMB2230N TMB2230N Models ABCD E 28 in. 48 in. 44 in. 11 in. 10 in. T30 (711 mm) (1219 mm) (1118 mm) (279 mm) (254 mm) 31.88 in. 49 in. 9 in. N/A N/A T45 (810 mm) (1245 mm) (229 mm) Models F G H I J 25.02 in. 42.76 in. 27.38 in. 31.5 in. 76.25 in. T30 (636 mm) (1086 mm) (695 mm) (800 mm) (1937 mm) 29.37 in. 48.62 in. 30.50 in. 34.5 in. 81.25 in. T45 (746 mm) (1235 mm) (775 mm) (876 mm) (2063.75 mm) N/A = Not Applicable NOTE: To
ページ13に含まれる内容の要旨
Specifications and Dimensions Exhaust Outlet Locations A B C TMB1969N TMB1969N Rear Exhaust Models Diameter A B C Elliptical 36.54 in. 4.25 in. 62.42 in. T30 Fits 8 in. (203 mm) (928 mm) (108 mm) (1585 mm) Elliptical 40.88 in. 4.75 in. 66.00 in. T45 Fits 10 in. (254 mm) (1038 mm) (121 mm) (1676 mm) 70304601 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 11
ページ14に含まれる内容の要旨
Specifications and Dimensions Gas Connection Locations C B 1 A TMB1970N TMB1970N 1 1/2 in. NPT Gas Connection Models AB C Non-CE and 75.20 in. 1.74 in. 36.84 in. Non-Australian (1910 mm) (44 mm) (936 mm) T30 CE and 75.28 in. 2.5 in. 30.60 in. Australian (1912 mm) (64 mm) (777 mm) 78.75 in. 4.12 in. 42.88 in. T45 (2000 mm) (105 mm) (1089 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70304601 12
ページ15に含まれる内容の要旨
Specifications and Dimensions Electrical Connection Locations B E A D C GAS AND STEAM ELECTRIC TMB1971N TMB1971N Electric Service Models Gas and Steam Models Electric Models ABCD E 59 in. 1.75 in. 35.63 in. 73.21 in. 2.28 in. T30 (1498 mm) (44 mm) (905 mm) (1859 mm) (58 mm) 62.5 in. 1.75 in. N/A N/A N/A T45 (1588 mm) (44 mm) N/A = Not Applicable 70304601 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 13
ページ16に含まれる内容の要旨
Specifications and Dimensions Steam Connection Locations C D A B A B TMB1972N Inlet Outlet Models AC B D 73.93 in. 6.29 in. 62.71 in. 2.39 in. T30 (Upper) (1877 mm) (160 mm) (1592 mm) (61 mm) T30 36.35 in. 6.29 in. 25.13 in. 2.39 in. (Lower) (923 mm) (160 mm) (638 mm) (61 mm) NOTE: All connections use 3/4 inch NPT pipe. © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 70304601 14
ページ17に含まれる内容の要旨
Installation Pre-Installation Inspection Location Requirements Upon delivery, visually inspect the crate, carton and The tumbler must be installed on a level floor. Floor parts for any visible shipping damage. If the crate, covering materials such as carpeting or tile should be carton, or cover is damaged or signs of possible removed. damage are evident, have the carrier note the condition To assure compliance, consult local building code on the shipping papers before the shipping receipt is
ページ18に含まれる内容の要旨
Installation WARNING To reduce the risk of severe injury, clearance of tumbler cabinet from combustible construction must conform to the minimum clearances. W056 1 3 4 2 5 6 7 TMB2110N TMB2110N NOTE: Shaded areas indicate adjacent structure. 1 0.5 in. (13 mm) recommended between machines for removal or installation. 2 Allow 2 – 4 in. (51 – 102 mm) opening at top of machine to aid in removal or installation. A removable trim piece may be used to conceal the opening; zero clearance allowed for t
ページ19に含まれる内容の要旨
Installation The stacked tumbler has a fifth leveling leg which is Position and Level the Tumbler shipped in the up position. The fifth leveling leg Unscrew the four shipping bolts (one at each corner). MUST BE installed properly on the lower left side of Remove tumbler from skid carefully to avoid putting the blower housing to stabilize the tumbler. Refer to pressure on the lower blower housing or motor Figure 3. assembly. After leveling with the four cabinet leveling legs, lower the fi
ページ20に含まれる内容の要旨
Installation IMPORTANT: The electronic ignition system will Before Placing Tumbler into Service attempt to light the gas by sparking for the “trial 1. Remove or open all panels and check accessible for ignition” period. Refer to Table 2. If gas does bolts, nuts, screws, terminals and fittings for tightness. not ignite within this period, the ignition control will go into a safety lockout and the valve will no 2. Replace all panels and guards. longer open until the control is reset. It may