ページ2に含まれる内容の要旨
Safety Precautions Safety Precautions .............3 FOR YOUR RECORDS Staple your receipt to this page in case you need it later. Write down the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased About the Controls on the Air Conditioner Controls..............................5 READ THIS MANUAL Ventilation ..........................6 Air Direction........................6 Inside you will find many helpful hints on ho
ページ3に含まれる内容の要旨
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING : This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION : property only. Meanings of symbols used in this manual are a
ページ4に含まれる内容の要旨
When the air filter is to be Do not clean the air Ventilate well when used conditioner with water. removed, do not touch the together with a stove, etc. metal parts of the unit. • It may cause an injury. • An oxygen shortage may occur. • Water may enter the unit and degrade the insulation. It may cause an electric shock. When the unit is to be Do not put a pet or house Do not use for special cleaned, switch off, and turn plant where it will be exposed purposes. off the breaker. to direct air flo
ページ5に含まれる内容の要旨
About the Controls on the Air Conditioner About the Controls on the Air Conditioner The controls will look like one of the following. Controls Model : HQ2081TH Off - Turns air conditioner off. Med Fan - Med speed fan operation without cooling. Low Fan - Low speed fan operation without cooling. High Cool - Cooling with high speed fan operation. Med Cool - Cooling with med speed fan operation. Low Cool - Cooling with low speed fan operation. This automatically controls the temperature of the indoo
ページ6に含まれる内容の要旨
Additional controls and important information. Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is drawn out. Part B Part A CLOSE VENT OPEN NOTE: Before using the ventilation feature, and prior to installing the front grille, pull down part until level with part . Air Direction The direction of air can be cont
ページ7に含まれる内容の要旨
About the Controls on the Air Conditioner Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. TO REMOVE: 1. Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille. 2. Using the tab, pull up slightly on the filter to release it and pull it
ページ8に含まれる内容の要旨
Features Learning parts name prior to installation will help you understand the installation procedure. Features VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) AIR DISCHARGE CABINET FRONT GRILLE AIR FILTER AIR INTAKE (INLET GRILLE) BRACE COMPRESSOR CONDENSER EVAPORATOR BASE PAN CONTROL BOARD POWER CORD 8 Features and Installation
ページ9に含まれる内容の要旨
Features and Installation INSTALLATION How to Install the Unit 1. To prevent vibration and noise, make sure the unit is installed securely and firmly 2. Install the unit where the sunlight does not Fence Awning shine directly on the unit. Cooled air 3. The outside of the cabinet must extend Heat outward for at least 28cm (11") and there radiation should be no obstacles, such as a fence or wall, within 50.8cm (20") from the back of the cabinet because it will prevent heat 1 About 12.7mm ( /2") 7
ページ10に含まれる内容の要旨
Installation Kit Contents NO. NAME OF PARTS Q'TY 2 3 4 1 1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3 BOLT 2 4 NUT 2 8 13 5 6 7 2 5 SCREW(TYPE A) (10mm( /5")) 16 D5.1mm(0.2") 6 SCREW(TYPE B) 3 16mm(0.63") D4.1mm(0.17") 7 SCREW(TYPE C) 5 16mm(0.63") 12 8 FOAM-STRIP 1 10 9 UPPER GUIDE 1 10 FOAM-PE (466mm x 10mm x 2mm) 1 11 9 11 FRAME GUIDE 2 14 12 WINDOW LOCKING BRACKET 1 13 FOAM-PE (920mm x 30mm x 2mm) 1 14 DRAIN PIPE 1 Suggested Tool Requirements SCREWDRIVER(+, -), RULER, KNIFE, HAMMER, PENCIL,
ページ11に含まれる内容の要旨
Features and Installation Cabinet Installation 1. Open the window. Mark a line on center of the window sill (or desired air conditioner location). Carefully place the cabinet on the Upper Guide window sill and align the center mark Window sill on the bottom front with the center Front Angle Fig. 1 line marked in the window sill. 9 Window Sash Upper guide 2. Pull the bottom window sash down behind the upper guide until it meets. 13 Foam-pe NOTE: Cabinet • Do not pull the window sash down so Fram
ページ12に含まれる内容の要旨
9. Attach each Frame curtain to the window sash using screws (Type C). (See Fig. 6) Type C 7 CAUTION: DO NOT DRILL A HOLE IN THE BOTTOM PAN. The unit is designed to operate 1 Fig. 6 with approximately 12.7mm ( /2") of water in bottom pan. 10. Slide the unit into the cabinet. (See Fig. 7) CAUTION: For security purposes, reinstall screws (Type A) at cabinet's sides. Power cord Screw (Type A) Fig. 7 Screw (Type A) 8 Foam-Strip 11. Cut the foam-strip to the proper length and insert between the upper
ページ13に含まれる内容の要旨
Features and Installation Electrical Data Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut Use 15 AMP, time or remove the grounding prong delay fuse or circuit from the plug. breaker. Power supply cord with Standard 125V, 3-wire grounding 3-prong grounding plug receptacle rated 15A, 125V AC USE OF EXTENSION CORDS Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA
ページ14に含まれる内容の要旨
Electrical Safety Because of potential safety hazards, we strongly IMPORTANT discourage the use of an adapter plug. However, if (PLEASE READ CAREFULLY) you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED (Fig. 17). The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polarity connection. The power
ページ15に含まれる内容の要旨
Before you call for service... Before you call for service... Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the thermostat click when the compressor cycles on and off. • Water will collect in the
ページ16に含まれる内容の要旨
Precauciones Importantes de PARA SU INFORMACION Seguridad Precauciones Importantes Escriba aquí los números de serie y modelo de las de seguridad ....................17 unidades exterior e interior: Nº de Modelo Nº Serie Los números figuran en una etiqueta en el lateral de cada unidad. Distribuidor Fecha de compra Instrucciones de Funcionamiento LEA ESTE MANUAL Controles...........................19 Ventilación.........................20 • Aquí encontrará numerosas sugerencias sobre cómo Como
ページ17に含まれる内容の要旨
Precauciones Importantes de seguridad Precauciones Importantes de Seguridad Para prevenir tanto lesiones al usuario u otras personas como daños materiales, es preciso seguir estas instrucciones. El manejo incorrecto debido a la inobservancia de estas instrucciones puede causar lesiones o daños cuya gravedad está clasificada en las siguientes indicaciones. ADVERTENCIA Este símbolo indica la posibilidad de lesiones mortales o graves. Este símbolo indica la posibilidad de lesiones o daños PRECAUC
ページ18に含まれる内容の要旨
PRECAUCION Cuando se vaya a quitar el No limpie el acondicionador Ventile bien cuando utilice el filtro de aire no toque las de aire con agua. acondicionador junto con partes metálicas de la unidad una estufa, etc. interior. • Esto podría causar heridas. • El agua podría entrar en la • En este caso tal vez se produzca unidad y degradar el aislamiento. una falta de oxígeno. También podría causar una sacudida eléctrica. Cuando limpie la unidad, NO ponga un animal doméstico No lo utilice para propó
ページ19に含まれる内容の要旨
Instrucciones de Funcionamiento Instruccionnes de Funcionamiento La apariencia de los controles será como uno de los siguientes. Controles Modelo : HQ2081TH Off(Apagado) :Apaga el aire acondicionado. Med Fan(Ventilador Medio) :Permite la operación de la velocidad media del ventilador sin enfriar. Low Fan(Ventilador Bajo) :Permite la operación de la velocidad baja del ventilador sin enfriar. High Cool(Enfriamiento Alto) :Permite enfriar con la operación de la velocidad alta del ventilador. Med Co
ページ20に含まれる内容の要旨
Controles adicionales e informacion importante. Ventilación La palanca de ventilación debe estar en posición CERRADA para poder mantener las mejores condiciones de enfriamiento. Cuando se necesite aire fresco en la habitación, coloque la palanca de ventilación en posición ABIERTA. La Compuerta es abierta y el aire de la habitación es expulsado. Parte B Parte A CERRADO VENT ABIERTO NOTA: Antes de utilizar la característica de ventilación, haga un kit de ventilación. Primero, hale hacia abajo la