CONTENTS INTRODUCTION................................................................................................................... 4 SPECIAL NOTES ................................................................................................................. 5 SAFETY PRECAUTIONS ..................................................................................................... 6 FEATURES ...................................................................................................
ページ4に含まれる内容の要旨
INTRODUCTION Congratulations on your purchase of a Lumex patient lift. The following pages will provide you with important safety and operating instructions on the use of patient lifts, slings, and accessories, as well as maintenance and warranty information. Read this manual carefully before operating your patient lift and refer to it as often as needed. Consult your Lumex dealer and/or healthcare professional with any ques- tions or concerns regarding safe and effective techniques for operatin
ページ5に含まれる内容の要旨
SPECIAL NOTES Warning: Do not operate this equipment without first reading and understanding this manual. If you are unable to understand the warnings, cautions and instructions, contact your dealer or a healthcare professional before attempting to use this equipment. Failure to do so may result in serious injury or damage to your patient lift. MAINTENANCE Maintenance MUST be performed by qualified personnel ONLY. Warning: Warning notices as used in this manual apply to hazards or unsafe practic
ページ6に含まれる内容の要旨
SAFETY PRECAUTIONS IMPORTANT: Before using patient lift, please read and adhere to the following safety precautions and warnings. Failure to do so could result in serious injury or damage to your patient lift. Always consult your healthcare professional to determine safe methods most suitable for your individual abilities. Protect yourself, your attendant and patient lift by having it serviced regularly. If you experience any malfunction, contact your Lumex dealer immediately, as a hazardous con
ページ7に含まれる内容の要旨
Warning: Unauthorized modification of your patient lift or the use of non-Lumex replace- ment parts may change the structure of the lift and could create a hazardous condition, which may result in serious injury and will void the warranty. Warning: LF1030 Hydraulic Patient Lift only: The hydraulic pump is sealed at the factory. If service is required, the unit must be returned to the factory for repair. DO NOT at- tempt to open the hydraulic pump or obtain local service; this will void the warra
ページ8に含まれる内容の要旨
FEATURES Battery, battery charger, & control box (LF1040 electric Boom patient lift only) Actuator (LF1040 electric patient lift only) Spreader bar LF1040 electric patient lift Mast 6-point suspension Push handle Hydraulic pump (LF1030 hydraulic patient lift only) See above left for LF1040 electric patient lift components Base adjustment handle Adjustable base Locking casters Swivel casters LF1030 hydraulic patient lift LF1040 electric patient lift (unless otherwise specified, callout applie
ページ9に含まれる内容の要旨
HANDLING PROCEDURES SHIPPING AND TRANSPORTATION INSTRUCTIONS If the patient lift is to be reshipped by common carrier, it should be packed in the same carton/s in which it was received (the LF1030 is shipped in one carton; the LF1040 motor may be packaged sepa- rately from the frame). Unpacking 1. Check for any obvious damage to the carton or its contents. If damage is evident, notify the carrier or your authorized Lumex Dealer. 2. Remove all loose packing from the carton. 3. Carefully remove al
ページ10に含まれる内容の要旨
ASSEMBLY INSTRUCTIONS The LF1030 patient lift is packed in one carton. The LF1040 motor may be in a separate carton. Com- ponents are shown in illustration below and called out in list below illustration. 7 3 1 4 8 5 6 9 2 LF1030 hydraulic patient lift components Item Qty Description 1) 1 Mast/Boom/Pump assembly (LF1030) 1 Mast/Boom/Actuator assembly (LF1040) 2) 1 Base 3) 1 Base adjustment handle 4) 2 Push handle 5) 2 Mast attachment bolt 6) 1 Base adjustment handle bolt 7) 1 Spreader bar 8) 1 L
ページ11に含まれる内容の要旨
Assembly 1. Remove the locking pin from the mast sleeve located on the rear of the base. 2. Install the L-inserts in the base. 3. With the boom pointed in the same direction as the base legs, insert the mast into the sleeve. 4. Insert the locking pin through the holes of the sleeve and mast, and attach the locking cable to the end of the pin. 5. Screw the two mast attachment bolts into the holes in the sleeve of the base. LF1030 HYDRAULIC PATIENT LIFT / LF1040 ELECTRIC PATIENT LIFT OWNER'S MANUA
ページ12に含まれる内容の要旨
6. Screw the push handles into the mast and tighten the nuts. 7. Remove the bolt from the top of the spreader bar, taking care not to drop the pin assembly. Install the spreader bar in the U bracket at the end of the boom. Align holes. Insert bolt and tighten. 8. Install the base adjustment handle in the socket located behind the mast sleeve on the base. With base handle to the far right position, insert and tighten base attachment bolt to ensure that the handle is firmly attached to the base. 9
ページ13に含まれる内容の要旨
Note: Steps 10-13 apply to LF1040 Electric Patient Control box Lift only. Cap screw 10. Attach control box using 5mm cap screws as shown at right. Battery charger Cap screw 11. Attach battery charger using 5mm cap screws as shown at right. 12. Clip battery onto unit. 13. See following Electrical connections section. Electrical connections (LF1040 only) The control box is the heart of the electrical system; into it plug the hand control, battery, and battery charger (depending on battery charger
ページ14に含まれる内容の要旨
Charging the battery with lift-mounted battery charger: With control box, battery charger, and battery assembled, insert the battery charger plug into a standard 110V receptacle. A green light signifying power and a yellow light signifying that the battery is charging will illuminate on the battery charger. When the battery is fully charged, the yellow light will shut off. The lift is now ready for use. Note: The patient lift will not operate during lift-mounted battery charging. Charging the ba
ページ15に含まれる内容の要旨
OPERATING INSTRUCTIONS LIFTING THE PATIENT Lifting the patient from a bed 1. Roll the patient onto their side. Place the folded sling behind the patient’s back. The center of the sling should be parallel with the patient’s spine. Roll the patient onto their back on top of the sling. 2. Pull the leg loops forward and under the thighs. 3. Cross the loops, one through the other. 4. Roll the patient lift under the bed, locating the suspension over the patient. Be careful not to lower the suspension
ページ16に含まれる内容の要旨
Lowering the patient onto a bed 1. Raise the patient lift until the patient’s buttocks are above the surface of the bed. Ensure that there are no obstacles underneath or around the bed. Move the patient lift under the bed. Be careful the patient does not hit any portion of the bed and that the patient’s legs have cleared the bed. 2. Center the patient over the bed, and rotate the patient to face the foot section of the bed. Carefully lower the patient onto the bed. It may be necessary to support
ページ17に含まれる内容の要旨
8. Slowly lower the patient into the wheelchair. 9. With one (1) attendant behind the wheelchair and the other operating the lift, the attendant behind the chair should pull back on the handle or sides of the sling to place the patient into the back of the chair. This will maintain a good center of balance and prevent the chair from tipping forward. Removing sling Gently pull the leg sections to the side, out from under the patient’s thighs. Standing by the patient’s side, lean the patient forwa
ページ18に含まれる内容の要旨
CARE AND MAINTENANCE Proper care and maintenance is essential to keeping your Lumex patient lift in a safe operating condi- tion. In addition to inspecting the unit before each use, periodic maintenance checks should be done. We further recommend that this unit be serviced at least once annually by an authorized dealer. Warning: It is extremely important that the patient lift be inspected before each use. Ensure that all hardware and accessories are secure and that the actuator is functioning pr
ページ19に含まれる内容の要旨
Cleaning Regular cleaning is recommended. A soft cloth, dampened with water and a mild NON-ABRASIVE detergent (household cleaner, soapy water, or hospital grade disinfectant) is all that is needed to clean your patient lift. Automobile wax or furniture polish will help maintain the finish over a long period of time. DO NOT wash under water pressure or steam clean. Checking for damage and wear It is extremely important to frequently check the areas of the patient lift that are under a great deal
ページ20に含まれる内容の要旨
MAINTENANCE SCHEDULE Note: Only qualified persons should service and repair your Lumex patient lift. Regular maintenance of your patient lift is necessary to ensure continuing proper and safe operation. Read and observe the following recommended maintenance schedule: Item Inspect Inspect/ Inspect/ Inspect/ initially adjust adjust adjust daily monthly every 6 months Base and Casters Ensure that base is level (all four wheels touch the floor) X X X Ensure tha