HE120, HE160 Humidifier
Installation Kit
INSTALLATION INSTRUCTIONS
WELCOME INSTALLATION
To the comfortable world of humidified air. When you use
Preparing for the Installation
your Honeywell humidifier, you notice that your skin is not
as dry, and that your scratchy throat and irritated nasal Be sure to identify all the required (Table 1) accessories
passages that aggravate allergies and asthma are (included) and make sure the appropriate tools are
steadily improving. available before begin
ページ2に含まれる内容の要旨
HE120, HE160 HUMIDIFIER INSTALLATION KIT For return duct mounting, the humidistat should be Determining Best Location for Humidifier mounted upstream from the humidifier or bypass so that Select a location for the humidifier on the supply it is properly sensing the relative humidity of the living (warm air stream) or the return plenum. See Fig. 1. space. Locate the control at least 8 in. (203 mm) Select a location for the bypass on the opposite upstream from the humidifier in the retur
ページ3に含まれる内容の要旨
HE120, HE160 HUMIDIFIER INSTALLATION KIT 7. Position the HE120 Humidifier base in the opening, mark the five screw holes, and pre-drill the screw DISK WHEEL holes. Insert the three 3/4 in. (19 mm) sheet metal screws 8. into the top holes. Hang the humidifier over the screws and secure 9. with the two remaining 1/2 in (13 mm) screws. Inside the humidifier housing, where the bypass 10. tube connects, snap the bearing bracket into place with the U-shape of the bracket pointing up. 11. Snap
ページ4に含まれる内容の要旨
HE120, HE160 HUMIDIFIER INSTALLATION KIT d. Insert the tubing into the float valve fitting and support the valve while tightening the compres- CAUTION sion nut. Chemical Hazard. Can cause personal injury or equipment NOTE: Do not over-tighten the compression nut. Mod- damage. erate tightness prevents leaking. Do not use any line connected to an air conditioner. e. Repeat steps a. through d. for saddle valve fit- Do not use gas line. ting. f. Secure tubing with clamps provided. 3. Use the sel
ページ5に含まれる内容の要旨
SUMMER WINTER HE120, HE160 HUMIDIFIER INSTALLATION KIT ENSURE TABS ON INLET AND MOTOR PLATE FIT INTO SLOTS IN LID FLANGES WATER OVERFLOW HOLE M20173 FLOAT ADJUSTMENT SLOT M20222 Fig. 10. Installing starter collar. Fig. 8. Adjusting HE160 water level. 4. Remove liner to expose foam adhesive. Position starter collar over opening. INSTALLING BYPASS 5. Using sheet metal screws, connect starter collar to Use inside of the 6 in. (155 mm) starter collar as a 1. the duct and bypass duct from humidi
ページ6に含まれる内容の要旨
HE120, HE160 HUMIDIFIER INSTALLATION KIT INSTALLING HUMIDISTAT HUMIDISTAT Mounting Duct Apply the template to the duct location chosen for 1. the humidistat. Make sure the template is level before drilling the holes. TRANSFORMER 2. Refer to the template (provided with the H8909 Humidistat Installation Instructions) to drill the con- trol assembly opening and mounting holes for the H8908. HUMIDIFIER BLACK DRIVE BLACK 3. Remove the H8908 case from the base. MOTOR Position the foam gasket on t
ページ7に含まれる内容の要旨
HE120, HE160 HUMIDIFIER INSTALLATION KIT TROUBLESHOOTING YOUR HUMIDIFIER (TABLE 2) Table 2. Troubleshooting Humidifier. Problem What to look for What to do Water leakage Leaking joints Shut off water. Tighten connections. Brass tubing inserts Verify that brass tubing inserts are used. Saddle valve leaking Verify rubber pad is installed on saddle valve. No water to basin. Electrical Verify control circuit wiring. Check all connections. Humidistat Turn humidistat up and down and listen for contact
ページ8に含まれる内容の要旨
HE120, HE160 HUMIDIFIER INSTALLATION KIT Home and Building Control Home and Building Control Honeywell Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled 69-1571 G.H. 09-01 www.honeywell.com/yourhome paper containing at least 10% post-consumer paper fibers.