ページ1に含まれる内容の要旨
Germ-Free Humidifier
uv sanitizing. Purified warm mist.
Model Number BWM-211D
636126_ins 0210_g ermf reeHumidifier_5”w x4.75”H_Output:100%_Prints:1/1,Blk
ページ2に含まれる内容の要旨
Table of conTeT n s Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 . - .6 . . . . . . . . . . . . . . . . Location of Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 .- . 8 . . . . . . . . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 . -1 .0 . . . . . . . . . . . . . . . . . . . . Filling the Water Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ページ3に含まれる内容の要旨
ca UTIon • T O REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER . THERE ARE NO SERVICEABLE PARTS INSIDE . • TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE . The lightning flash with arrow-head symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the unit’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock . The exclamation point
ページ4に含まれる内容の要旨
DanG eR To reduce the risk of electric shock, burns, fire or injury: 1 . Do not use while bathing or in a shower . 2 . Do not place or store unit where it can fall or be pulled into a tub or sink . 3 . Do not place in, drop or submerge in water or other liquid . 4 . Do not reach for unit that has fallen into water . Unplug it immediately . 5 . Care should be taken so that objects do not fall and liquids are not spilled onto the unit . WaR n InG 1 . Close supervision is necessary when this
ページ5に含まれる内容の要旨
8 . Never block the air openings of the unit with materials such as clothing, plastic bags or papers, or place it on a soft surface such as a bed or couch, where the air openings may be blocked . 9 . Do not overload electrical outlet . Use only the power source as indicated . 10 . Do not carry this unit by cord or use cord as handle . 11 . Never operate this unit if it has a damaged cord or plug, if it is not working properly, or if it has been dropped or damaged, or dropped into water .
ページ6に含まれる内容の要旨
IMPoRTanT safeGU aRDs Cauti On : BeCause Hig H tem Peratures are generated in t His Humidifier , Basi C safet Y Pre Cauti Ons s HOu Ld a Lwa Ys Be f OLLOwed , es PeCia LLY w Hen CHiLdren are Present . When using electrical appliances, these basic safety precautions must be followed: 1 . DO NOT operate the humidifier without the water tank . 2 . ALWAYS use clean, cool tap water to fill the water tank . 3 . To avoid risk of fire or shock, DO NOT use an extension cord . 4 . DO NOT handle th
ページ7に含まれる内容の要旨
13 . ALWAYS place the unit on a firm, flat, level, water-resistant surface and arrange the power cord so that the product is unlikely to be upset . 14 . DO NOT clean the product or service the UV bulb without disconnecting the power cord . 15 . Before connecting to electric power outlet, check your electrical power supply . It must be 120 volts AC (alternating current) . The outlet may be 15 amp or 20 amp . The circuit must be of adequate size and must be protected by fuse or circuit b
ページ8に含まれる内容の要旨
l oca TIon of PaRTs an D c onTRols 1 . Water Tank 2 3 2 . Tank Handle 3 . Medication Cup 4 4 . Mist Outlet Grille 5 . Mineral Absorption Pad 1 6 . Hot Water Reservoir 7 . Base 8 . Base Drain Cap & Gasket 9 . Digital Control Panel 10 . Cold Water Reservoir 11 . Tank Cap with Gasket 11 5 10 6 7 9 8 7
ページ9に含まれる内容の要旨
DIGITal conTRol Panel 1 . Power/Mode Button 5 . Humidity Level Button 2 . Power Indicator Light 6 . Mode Screen Indicator 3 . Replace UV Bulb Indicator Light 7 . Set Humidity Screen Indicator 4 . Refill Tank Indicator Light 8 . Percent Humidity Screen Indicator 2 3 4 1 8 7 6 5 8 636126_ins 0210_g ermf reeHumidifier_5”w x4.75”H_Output:100%_Prints:1/1,Blk
ページ10に含まれる内容の要旨
oP eRaTInG I nsTRUc TIons Carefully unpack humidifier and remove all packing material . n Ote : w hen you unpack your humidifier, you may find it has droplets of water on some surfaces. t his is normal as every unit is tested prior to shipping. aBO ut PO wer /mOde POWER/MODE button can be pushed to either OFF, HI or LO mode . On HI, humidifier will operate on maximum power . On LO, humidifier will operate more quietly on reduced power . The mode will be indicated in the MODE window of
ページ11に含まれる内容の要旨
oP eRaTIon 1 . Place the base of the unit on a firm, flat, level and water-resistant surface . 2 . Fill the WATER TANK according to the instructions on the next page and place it on the humidifier base . 3 . Plug the power cord firmly and completely into the wall outlet . 4 . Push POWER/MODE switch to either the HI or LO position . Push SET HUMIDITY button until desired humidity appears in the SET HUMIDITY window of the digital display . The humidity can be set in 5% increments betw
ページ12に含まれる内容の要旨
f Ill InG The W aTeR Tan K REFILL WHEN LIT—When illuminated, the water tank needs refilling . “REF” will also be indicated in the MODE window at this time . If still illuminated after full tank is placed on base, see TROUBLESHOOTING section . 1 . Before filling the WATER TANK, push POWER/MODE switch until OFF appears in MODE window and unplug unit . 2 . Remove WATER TANK from base, turn the tank upside down and remove TANK CAP by turning counterclockwise . Fill tank with clean, co
ページ13に含まれる内容の要旨
warning : d O n Ot use any liquid medication other than those specifically recommended for use with a steam vaporizer or warm mist humidifier. d O n Ot pour medication directly into the mist Out Let gri LLe openings nor add it to the water in the tank or tray. MIne Ral absoRPTIon P aD I nsTRUc TIons Warm mist humidifiers do not spread fine mineral dust into the air that you breathe nor onto your furniture, the way that other types of humidifiers do . The mineral dust remains trapped in the
ページ14に含まれる内容の要旨
clean InG an D MaI nTenance Water contains minerals and other particles . During operation, most of these minerals will remain in the water reservoir . Gradual buildup of deposits will coat the hot water reservoir and reduce its efficiency . The importance of routine cleaning and care cannot be over-emphasized . Hard water contains more minerals and other particles . If a mineral absorption pad appears to disintegrate (normally due to use of softened water), discontinue use of pads . CL
ページ15に含まれる内容の要旨
5 . Pour about 1 cup of white vinegar into either reservoir and allow it to soak for only 20 to 30 minutes . 6 . Hold the base of the humidifier over the sink and tilt it on its side to empty the vinegar . Fill the cold and hot water reservoirs with clean, warm water to remove all traces of the vinegar . Remove any buildup of minerals in the hot water reservoir using a small brush, such as a toothbrush . NOTE: The buildup is due to water hardness . The harder your water, the more oft
ページ16に含まれる内容の要旨
RePlacI nG Uv b Ulb If the REPLACE UV BULB WHEN LIT signal light is illuminated during normal use, the bulb must be replaced with the same special 3 .5W bulb, EUV-13B . The UV bulb will operate at maximum output for approximately 2,000 hours . The UV bulb may operate longer than 2,000 hours but at a reduced output . To keep your humidifier operating at maximum efficiency it is recommended that the UV bulb be replaced after 2,000 hours of use . 1 . If the REPLACE UV BULB indicator illu
ページ17に含まれる内容の要旨
8 . Take a replacement 3 . 5W UV bulb that you purchased from Kaz Incorporated or another supplier and change the bulb . To prolong the life of the bulb, limit your direct contact with the glass of the bulb by using a cloth or tissue to screw it into place . Mail questions or comments to: Kaz, Incorporated, Consumer Relations Dept . , 250 Turnpike Road, Southborough, MA 01772 . Please be sure to specify model number . Call toll-free at: 800-477-0457; E-mail: consumerrelations@kaz . com;
ページ18に含まれる内容の要旨
imPOrtant n Ote : even though you will not receive maximum germicidal effects, you can still use your humidifier until the replacement bulb arrives. n Ote : You may hear a rattling sound and notice a small, round object inside your bulb. t his is normal. Your bulb is fully operational. n Ote : d iscard the old uv bulb cartridge at a household hazardous waste collection site. Bulb and bulb housing are not intended for use with any other product or purpose. Lamp contains mercury. manage in a
ページ19に含まれる内容の要旨
sP ecI f Ica TIons Output per Day: . . . . . . . . . . . . . . . 2 . . G . al . lo . ns . . . . Electrical usage: . . . . . . . . . . . . . . . .2 . 6 . 0W . . H .ig .h ., 1 .30W Low Weight (without water): . . . . . . . . . . .6 . .3 .4 . lb .s . . Water Tank Capacity: . . . . . . . . . . . . 2 . .1 . . G . al . lo . ns . Dimensions (approximately) . . . . . . . . . 8 . . 25 . " . w . x 14 .25" l x 11 .50" h 18 636126_ins 0210_g ermf reeHumidifier_5”w x4.75”H_Output:100%_Prints:1/1,Blk
ページ20に含まれる内容の要旨
TRoU bleshoo TInG issue POssi BLe Cause sOLuti On Unit is not plugged in . Plug in unit . Unit does not mist . Power failure . Check circuit breaker . Water tank is empty . Remove and refill water . Power switch not Turn on switch . turned on . Unit still on REFILL Check that there is water after refilling tank . in the hot water reservoir . Float on bottom Carefully clean any of tank “hangs up” . residue or obstruction . Water tank not properly Reposition situated on base . wate