ADDENDUM - All Export 880/850 Hot Tub Models
880/850 Export 50Hz Owner’s Manual Update, #6530-317 Rev-A
The following changes apply to the owners manual identified above:
• Fluidix Intelli-Jet Operation Details (page 1)
• New Change Filter Reminder Feature (page 2)
• Revised Hot Tub Gravity Drain Operation Procedure (page 2)
• Revised 2005+ Cameo Hot Tub “Top View” Figure-F (page 3)
• Revised Light Button Operation Instructions (page 4)
• New AquaTerrace Light Controller Operation for 200
ページ2に含まれる内容の要旨
Programming The Change Filter Reminder Display Your new spa may be equipped with a programmable CHANGE “Change Filter” reminder that appears on the control FILTER panel display after a specified number of days. It is designed to remind you to clean and/or replace your filter cartridge(s) on a regular basis but does not affect spa operation in any way. This reminder must be reset at each filter cleaning inter- val. It offers a selectable range from 10-120 days or can be dis- abled. We recomm
ページ3に含まれる内容の要旨
Figure-F, Hot Tub Top View 21 7 16 7 10 19 4 5 4 18 5 8 5 5 18 24 18 11 11 18 6 18 18 20 18 7 11 10 11 11 11 17 12 2 11 11 11 13 6 12 8 12 11 88 9 13 7 25 3 23 6 11 11 6 5 4 6 11 11 14 15 6 25 2 21 7 Select Cycle Mode Display e e 1 22 Note: 2005+ Cameo Model with Optional Audio System Illustrated. 2005+ Cameo/ Optima models include the new AquaTerrace waterfall control valve #16, waterfall #19, and light controller #20 as shown. These items are excluded from all other models listed in this man
ページ4に含まれる内容の要旨
Waterfall(s) Footwell 850 Light Operation (2005+ Marin, Altamar, Capri) The spa light offers 6 constant color variations and a unique random mode for enhanced spa enjoyment. Press the LIGHT sensor pad once to turn the spa light on in “Random” mode, then repeatedly press the sensor pad to turn the light off or to select one of 6 constant colors illustrated below. RANDOM OFF RED OFF GREEN OFF BLUE OFF ORANGE OFF TEAL OFF VIOLET OFF Spa Light Sequence 880 Light Operation (2005+ Optima & Cameo) The
ページ5に含まれる内容の要旨
880 Waterfall Control Valve (2005+ Optima & Cameo) 4x Turn valve counterclockwise to increase waterfall output. Full On Turn clockwise to decrease or turn off waterfall output. Note: it takes 4 full revolutions to change the waterfall 4x from a full off to a full on flow rate. Full OFF 880 Filter Cartridge Replacement (2005+ Optima & Cameo) A programmable “Change Filter” reminder flashes on the CHANGE control panel display after a specified number days to remind FILTER you to inspect and/or r
ページ6に含まれる内容の要旨
D E A Filter Nut Trapped Air A Bubbles B C Submerge new filter cartridge in spa and tilt 1. Install new filter cartridge, then tighten filter nut until each end upward to remove most of the it just touches filter face. DO NOT OVERTIGHTEN! air bubbles trapped inside the filter. 2. Turn power to hot tub back on. Replacement MicroClean II filter cartridges may be purchased from your Sundance dealer. An optional pleated filter cartridge is also available from your Sundance dealer. This filter c
ページ7に含まれる内容の要旨
850 Export Series Séries Exportation 850 850er Serie Export Installation & Owner’s Manual Instructions en Français Installations- und Bedienungsanleitung
ページ8に含まれる内容の要旨
ENGLISH Table of Contents 1.0 Important Hot Tub Owner Information ..................................1 2.0 Important Safety Instructions...................................................2 3.0 Locating Your Sundance Hot Tub.............................................5 3.1 Outdoor Locations..........................................................................................5 3.2 Indoor Locations..............................................................................................5 4.
ページ9に含まれる内容の要旨
ENGLISH 11.0 Hot Tub Maintenance................................................................28 11.1 Cleaning The Filter.......................................................................................28 11.2 Draining and Refilling .................................................................................29 11.3 Cleaning The Hot Tub Interior.................................................................30 11.4 Pillow Care.........................................................
ページ10に含まれる内容の要旨
ENGLISH 1.0 Important Hot Tub Owner Information Your Sundance hot tub is constructed to the highest standards and is capa- ble of providing many years of trouble-free use. However, because heat retentive materials are utilized to insulate the hot tub for efficient operation, an uncovered hot tub surface directly exposed to sunlight and high tempera- tures for an extended period is subject to permanent damage. Damage caused by exposing the hot tub to this abuse is not covered by warranty. We rec
ページ11に含まれる内容の要旨
ENGLISH 2.0 Important Safety Instructions When using this electrical equipment, basic safety precautions should always be followed, including the following: 1. READ AND FOLLOW ALL INSTRUCTIONS BEFORE OPERATING THE HOT TUB! 2. DANGER - RISK OF ELECTRICAL SHOCK: Install at least 1.5m, from all metal surfaces. A hot tub may be installed within 1.5m of metal sur- faces, if in accordance with the country electrical code. 3. DANGER - RISK OF ELECTRICAL SHOCK: Do not permit any electri- cal appliance,
ページ12に含まれる内容の要旨
ENGLISH 8. Overflowing or Overfilling: Overfilling can cause the hot tub to siphon out water through the air venturis. Overfilling problems are not covered by the warranty. 9. Before entering a hot tub, the user should measure the water tempera- ture with an accurate thermometer since the tolerance of the water temperature-regulating device may vary as much as ±3°C. 10.Always enter and exit the hot tub slowly and cautiously. Wet surfaces will be slippery. 1 1. Do not use the hot tub while alon
ページ13に含まれる内容の要旨
ENGLISH 19.Persons using medication should consult a physician before using a hot tub since some medications may induce drowsiness while other med- ications may affect heart rate, blood pressure, and circulation. 20. Long exposures in the hot tub may result in nausea, dizziness or faint- ing. Observe a reasonable time limit, leave the hot tub, then shower, cool down, and if you wish, return for another brief stay. 21. Excessive temperatures may cause hyperthermia. The symptoms and first aid i
ページ14に含まれる内容の要旨
ENGLISH 3.0 Locating Your Sundance Hot Tub IMPORTANT: Because of the combined weight of the hot tub, water and users, it is extremely important that the base upon which the hot tub rests be smooth, flat, level and capable of uniformly supporting this weight, without shifting or settling, for the entire time the hot tub is in place. If the hot tub is placed on a surface which does not meet these requirements, damage to the skirt and/or the hot tub shell may result. Damage caused by improper sup-
ページ15に含まれる内容の要旨
ENGLISH If you have any questions regarding the placement or installation of your hot tub, consult your authorized Sundance Dealer. 4.0 General Electrical Safety Instructions TM Your new Sundance hot tub is equipped with the "state-of-the-art" Sentry equipment system. It contains the most advanced safety and self-protective equipment in the industry. Nonetheless, this hot tub must be installed prop- erly to insure dependable usage. Please contact your local government authority should you have
ページ16に含まれる内容の要旨
ENGLISH Before installing this hot tub, check with the local government/electrical authority to insure installation conforms to local country/area states codes. 5.0 Electrical Installation Instructions (240V Service) IMPORTANT NOTICE: The electrical wiring of this hot tub must be installed by a qualified electrician to comply with all regulations and standards spec- ified by the electrical authority in your state or country. Figure-B, Sentry Control Box Figure-C, Terminal Block TB1 230V Wire
ページ17に含まれる内容の要旨
ENGLISH 4. Select the power supply cabinet inlet you want to use (Figure-A, Page 6), Install the power cable through the large opening provided in the bottom of the metal control box. 5. Hot tubs with one main terminal block (Figure-B, Page 7) must be supplied with 20 Amps. Note: the 850 series hot tub can be adapted to use higher amperage circuits when available. Contact your Sundance dealer for details. 6. The electrical supply for this product must include a suitably rated isolating swit
ページ18に含まれる内容の要旨
ENGLISH CAPRI Models Voltage 230 VAC 230 VAC Frequency 50Hz 50Hz Max. Current Draw 12.1 Amps* 23.6 Amps** Wattage: 2.8kW 5.4kW Number of Wires Three Three * Standard 12.1 Amp (2.8kW) configuration: the heater will not operate while the jets pumps is running. ** Alternate 23.6 Amp (5.4kW) configuration: the heater will operate while the jets pumps is running. Listed above are the most common power configurations by model. Current/wattage requirements for each model change depending on device* a
ページ19に含まれる内容の要旨
ENGLISH • Fill the hot tub until the water level is midway in the filter bucket skim- mer opening and above all jets. Do not overfill. Important: Always fill your hot tub through the filter bucket after draining. Failure to do so may cause air to be trapped in either pump, preventing the pump from circulating water. • Remove hose and replace filter cartridge as illustrated in section 1 1.1, page 28-29 (Figure-G). C. Turn On Power Turn on power to hot tub at the home’s circuit breaker. The heate
ページ20に含まれる内容の要旨
ENGLISH When power is turned on, the spa defaults to STANDARD mode. In STANDARD mode, the skimming/heating cycle will activate pump 1 as programmed to provide skimming action and additional filtration. In ECONOMY mode, the skimming/heating cycle will not come on. This is the main difference between the two operating modes. WARNING - RISK OR INJURY Always check the water temperature carefully before entering the hot tub. H. Setting Desired Temperature To warm hot tub water to a comfortable