ページ1に含まれる内容の要旨
®
Model No. IMHS63100
Serial No.
USER’S MANUAL
The serial number is on a plastic sign
inside the spa behind the access panel.
Record the serial number in the space
above.
Access Panel
QUESTIONS?
As a manufacturer, we are com-
mitted to providing complete
customer satisfaction. If you
have questions, or if there are
missing parts, we will guarantee
complete satisfaction through
direct assistance from our factory.
TO AVOID UNNECESSARY
DELAYS, PLEASE CALL DIRECT
TO OUR TOLL-FREE CUSTOMER
HOT LINE
ページ2に含まれる内容の要旨
Table of Contents Posting the Warning Sign . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Choosing a L
ページ3に含まれる内容の要旨
Important Safety Instructions WARNING: To reduce the risk of drowning, electric shock, or serious injury, read the fol- lowing important precautions before using the hydrotherapy spa. READ AND FOLLOW ALL INSTRUCTIONS 1. It is the responsibility of the owner to ensure 10. Never insert any object into any opening. that all users of the hydrotherapy spa are 11. Do not use breakable containers in or near adequately informed of all precautions. the hydrotherapy spa. 2. Use the hydrotherapy spa only a
ページ4に含まれる内容の要旨
20. DANGER—Risk of electric shock. Keep all physician before using the hydrotherapy spa. electrical appliances such as radios, tele- Pregnant women should not use the spa if phones, televisions, and lights at least five the water temperature is above 100°F; the feet away from the water. unborn child could be seriously harmed. This is especially important during the first 90 21. A wire connector is provided on the electron- days of the pregnancy. ics pack of the hydrotherapy spa to connect a 2 mi
ページ5に含まれる内容の要旨
35. WARNING: The spa jets produce a stream of water with relatively high pressure. Prolonged exposure of a localized area of the body may cause bruises to the skin. 36. The included warning sign must be posted where all users of the hydrotherapy spa can see and read it. (See POSTING THE WARNING SIGN on page 2.) 37. WARNING DECAL PLACEMENT: Locate the decals shown below and familiarize yourself with the information on the decals. WARNING: Read all instructions before using the hydrotherapy spa. I
ページ6に含まれる内容の要旨
Before You Begin ® Congratulations for selecting the new IMAGE For your benefit, read this manual carefully before RENEW 631 hydrotherapy spa. The innovative using the RENEW 631. If you have additional ques- RENEW 631 allows you to enjoy all the benefits of tions, please call our Customer Service Department hydrotherapy in the comfort and privacy of your home. toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). Hydrotherapy is a proven met
ページ7に含まれる内容の要旨
Choosing a Location for the Hydrotherapy Spa There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you plan to use the spa inside or outside. We have listed several factors you may wish to consider as you decide where to set up the spa. If you set up the hydrotherapy spa inside: If you set up the hydrotherapy spa outside: 1. The spa will increase the level of humidity in your 1. Check local building codes concerning th
ページ8に含まれる内容の要旨
Assembly Before beginning assembly, carefully read the ASSEMBLY REQUIRES THE FOLLOWING following information and instructions: TOOLS (not included): • Place all parts in a cleared area and remove the • One (1) phillips screwdriver packing materials from the spa shell. Do not dis- pose of the packing materials until assembly is • You may also need a small amount of soap completed and the spa is operating. or water. • During assembly, make sure that all parts are A wire connector is provided on
ページ9に含まれる内容の要旨
3. Refer to the drawing on page 6 and locate the 3 heater access opening. Gate Valve Locate the two indicated gate valves inside the Collar heater access opening. Make sure that the gate valves are open and that the locking clips are snapped onto the stems of the gate valves (refer to the inset drawing in step 2 on page 8). Gate Make sure that the four indicated collars are tight- Collar Collar Valve ened. Electronics Pack Refer to step 1. Re-attach the heater Access Panel (5) to the spa with th
ページ10に含まれる内容の要旨
Using the Hydrotherapy Spa The hydrotherapy spa is designed to seat five adults. If the level is too high, add half of one of the “QUICK The spa holds 295 gallons of water and offers a heat- pHix It DOWN” packets to the water. Let the water cir- ing system (80°F to 104°F), a filtration system, and culate through the spa for five minutes. Test the pH adjustable hydrotherapy jets. Follow the guidelines level again. Repeat until the pH level is correct. below to use and maintain the spa for your lo
ページ11に含まれる内容の要旨
Spa Shell Diagram D D O O A A D C E K E H F K B I J A A P N O M L G A. The eight adjustable push/pull jets allow you to I. The temperature probe monitors water tempera- direct their water flow and can be closed and ture. opened with a push or a pull on their nozzles. Water pressure to the other hydrotherapy jets can be J. The underwater light can be used for night opera- increased by closing the adjustable push/pull jets. If tion (see USING THE CONTROLS on page 12). no air flows through the jets
ページ12に含まれる内容の要旨
Using the Controls Air Control 1 Air Control 2 Display Display Invert Button l ll Jet Jet Light Temperature Button 1 Button 2 Button Buttons Refer to the diagram above. The function of each Jet Button 1: Turns the spa jets labeled A (at the left) control is explained below: on and off. If the button is pressed once, the jets will run, providing gentle hydrotherapy. If the button is Display Invert: Turns the Display 180°, allowing it to pressed again, the jets will shut off. be read from the ins
ページ13に含まれる内容の要旨
Maintenance The hydrotherapy spa is designed to provide years of MAINTAINING THE SPA COVER enjoyment. Please follow the guidelines below to properly maintain your spa. The spa cover should be cleaned monthly. To clean the spa cover, use water and a non-abrasive cleaner MAINTENANCE SCHEDULE on the entire cover. Rinse the cover with a garden hose to remove any cleaner residue. Dry the cover Daily entirely. Use a non-silicone-based vinyl conditioner on • Check the water level and refill the spa to
ページ14に含まれる内容の要旨
WATER CHEMISTRY ATTACHING AND REMOVING THE ACCESS PANEL The hydrotherapy spa comes with a starter chemical To locate the access panels, refer to the drawing on pack for maintaining the water in the spa. (See TEST- page 6. Turn off the spa power. To remove an access ING AND TREATING THE WATER on page 10.) panel, first remove the four indicated screws. Slide Additional chemicals can be purchased at a pool and the access panel down and then pull the bottom of it spa supply store. away from the spa.
ページ15に含まれる内容の要旨
To drain the hydrotherapy spa, follow the steps below: WINTER USE AND CARE 1. Using the console, adjust the temperature to the lowest setting. The hydrotherapy spa is designed for year-round use. 2. Shut off the power to the spa, at the circuit breaker If you decide to store the spa for the winter, store it in or GFCI. a warm, dry location. Follow the steps below to winter- 3. Remove the pump access panel from the spa. ize the spa. 4. Remove the end of the drain hose from the spa. 1. Make sure t
ページ16に含まれる内容の要旨
Trouble-shooting Most problems can be solved by following the simple steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time. 1. SYMPTOM: THE SPA WILL NOT OPERATE tained at 70°F, it will take approximately 6 to 8 hours for the water to reach the set tempera- a. Check to see if the GFCI breaker is tripped or ture. was not turn
ページ17に含まれる内容の要旨
10. SYMPTOM: THE SPA JET UNIT CONTINUES 12. SYMPTOM: THE CONSOLE DISPLAYS THE TO RUN AFTER IT HAS BEEN SHUT OFF WORDS “COOL” OR “ICE” a. To turn the main jets off, press the pump button a. This is a normal function of the spa; no action once. NOTE: If the actual spa water tempera- is necessary. The word “COOL” will appear in ture is below the set temperature, or if the spa the display if the temperature of the water is is running a filter cycle, the heater pump/motor more than 20°F cooler than t
ページ18に含まれる内容の要旨
R0700A Part List—Model No. IMHS63100 Key No. Qty. Description Key No. Qty. Description 1 1 Thermometer Fitting 28 2 Drain Plug O-ring 2 2 Long Access Panel 29 1 Small Quick-release Bracket 3 1 Adjustable Whirlpool Jet 30 8 Buckle 4 1 Heater Pump/Motor 31 16 #4 x 3/4” Screw 5 2 Short Access Panel 32 13 Whirly Jet 6 2 Heater Pump/Motor O-ring 33 1 Filter Cover O-ring 7 32 1/4” x 1 1/2” Machine Screw 34 2 Air Control Knob 8 1 Filter Cover 35 11 1/4” x 1 1/4” Bolt 9 4 #10 x 1 3/4” Sheet Metal Screw
ページ19に含まれる内容の要旨
R0700A Exploded Drawing—Model No. IMHS63100 11 35 22 20 35 13 24 24 23 35 38 38 29 24 13 35 20 38 28 22 35 27 6 13 24 24 24 38 38 4 38 13 36 35 9 8 28 1 27 19 24 24 33 38 38 14 36 16 9 15 21 32 30 32 26 32 26 34 31 40 25 39 10 40 3 26 25 37 12 2 17 5 7 18 18 17 17 7 25 19
ページ20に含まれる内容の要旨
Ordering Replacement Parts To order replacement parts, simply call our Customer Service Department toll-free at 1-877-897-7493, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays). To help us assist you, please be pre- pared to give the following information when calling: 1. The MODEL NUMBER of the product (IMHS63100) ® 2. The NAME of the product (IMAGE RENEW 631 hydrotherapy spa) 3. The SERIAL NUMBER of the product (see the front cover of this manual) 4. The KEY NU