ページ1に含まれる内容の要旨
®
HAYWARD
LISTED
SWIMMING POOL AND
SPA CONTROL
3Z62
2100 SERIES
POOL SYSTEM CONTROL
CONSUMER OPERATING INSTRUCTIONS
Designed and engineered for
todays carefree lifestyle, this 2100
series sets new standards of ease of
operation and performance for remote pool system control.
Easy to use master remote control allows you to monitor, set
and control up to 12 functions necessary for total pool system
control as well as pool environment control.
Manufactured under the following U.S. patents: 618797,
ページ2に含まれる内容の要旨
IMPORTANT SAFETY INSTRUCTIONS WHEN USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD BE FOLLOWED, INCLUDING THE FOLLOWING: FAILURE TO FOLLOW INSTRUCTIONS MAY RESULT IN INJURY. READ AND FOLLOW ALL INSTRUCTIONS 1. DANGER - Risk of electric shock. Do not permit any electrical appliance such as a light, telephone, radio, or television within 5 feet (1.5M) of a pool or spa. 2. All electrical work must be performed by a qualified electrician and must conform to all national, state, an
ページ3に含まれる内容の要旨
BUTTON FUNCTIONS FOR MASTER CONTROL PANEL & SPA SIDE CONTROL PANEL MASTER CONTROL PANEL BASIC FUNCTION BUTTONS UP BUTTON- Used in conjunction with Program AUXILIARY 1 - 6A max button for many automatic settings, including fill A. Turns the pool feature on and off. Will not valve operation (if installed). 1-2 hour time out. activate filter pump if dip switch #4 is down. DOWN BUTTON- Displays Ph and/or ORP B. Controls the cleaner pump in conjunction and/or PSI with each press (if installed).
ページ4に含まれる内容の要旨
WIRELESS REMOTE OPERATION RF SPA REMOTE BASIC BUTTON FUNCTIONS TEMP UP BUTTON - Increases temperature (same increments as when changing the temperature from the spa side control panel). TEMP DOWN BUTTON - Decreases temperature (same decrements as when changing the temperature from the spa side control panel). SPA BUTTON - Switches the valve between spa and pool, 24 hour timeout when in the spa position, turns the filter pump on in the spa position. JETS/BLOWER BUTTON - Turns the jets and blower
ページ5に含まれる内容の要旨
BASIC PROGRAMMING OF MASTER CONTROL PANEL NOTE: BE SURE TO PROGRAM MASTER CONTROL PANEL USING THIS SEQUENCE. TO PROGRAM TIME OF DAY: 1. Push Program button, display will blank out with the exception of the “SET” icon. 2. Push Program again and current time of day will display. At this point, time of day may be adjusted by use of the Up and Down buttons. You will see the words “SET TIME OF DAY” on the display and the hours flashing. To set the hours and AM/PM, press the Up or Down button. 3. Af
ページ6に含まれる内容の要旨
BASIC PROGRAMMING OF MASTER CONTROL PANEL (continued) TO PROGRAM POOL AND SPA SET TEMPERATURE: 1. Push Program button, display will blank out with the exception of the “SET” icon. 2. Push Heater button and display will show current desired set temperature of spa. Display will show “SET TEMPERATURE OF SPA.” Set temperature may be adjusted with the Up and Down buttons. Range is 70°F - 104°F (21°C - 40°C). 3. Push Program again and display will show current desired set temperature of pool. Displ
ページ7に含まれる内容の要旨
BASIC PROGRAMMING OF MASTER CONTROL PANEL (continued) TO PROGRAM OPTIONAL FILL VALVE 1. Push the Program button and then the up button and display will show “SET # OF HOURS TO FILL (1 OR 2 HRS).” Number of hours to fill pool may be adjusted between 1 and 2 hours by pushing the Up button. 2. To start filling the pool, push the Down button. This will turn on the fill valve. Display will show the “FILL” icon. 3. When the pool is filling, pushing the Up button will turn the fill valve off. TO PRO