ページ1に含まれる内容の要旨
SERIES AL5000
LIGHT TOWER
OPERATION/SERVICE
& PARTS MANUAL
California Proposition 65
WARNING
The engine exhaust from this product
contains chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.
PO Box 3147 • Rock Hill, SC 29732 USA • Phone 803-324-3011
Toll Free 800-433-3026 Parts Department Fax 800-633-5534
1
ページ2に含まれる内容の要旨
NOTES 2
ページ3に含まれる内容の要旨
TABLE OF CONTENTS Receiving and Set-up Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7 Check Out on Receipt/Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 TEREX Amida Light Tower Model Coding System . . . . . . . . . . . . . . 9 Recommended Engine Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Operating Instructions Light Tower Operating Instructions. . . . . . . . . . . . . . . . . . . . . . .
ページ4に含まれる内容の要旨
NOTES 4
ページ5に含まれる内容の要旨
SAFETY PRECAUTIONS The following symbols in this manual signal potentially dangerous conditions to the operator or equipment. Read this manual carefully. Know when unsafe conditions can exist. Then, take necessary steps to protect personnel, as well as equipment. WARNING: TEREX Amida uses this symbol throughout this manual to warn of possible fatal injury. CAUTION: TEREX Amida uses this symbol to point out potential damage to equipment. Lamps, fuels, electrical equipment, batteries, exhaust g
ページ6に含まれる内容の要旨
• Guard Against Battery Hazards Lead acid batteries can be dangerous. The sulfuric acid in the battery can cause severe skin and eye burns. The hydrogen gas emitted during charging can explode if an arc or flame is present near the battery. Use precautions to prevent acid burns or explosive conditions. Do not smoke while servicing batteries. Do not allow tools to touch battery terminals and create an arc. Do not test battery voltage by setting up a brief arc at the terminals. Use a multimete
ページ7に含まれる内容の要旨
• Do Not Touch Hot Parts The exhaust manifold and tailpipe are very hot. Parts of the engine are also hot. Avoid touching hot parts of the engine or tailpipe. Use protective gloves when handling hot parts. • Be Alert And Attentive To The Task Read the safety instructions and operating procedures before attempting to troubleshoot or work on this unit. Also read the engine manual, which is a separate booklet that is provided with this manual. Do not work on this equipment when mentally or physi
ページ8に含まれる内容の要旨
CHECK OUT ON RECEIPT OF DELIVERY: The tower will be serviced, tested and ready for operation when received except for export units and skid mount units which are knocked down for shipping (export units are also shipped with dry batteries). Amida recommends the following checks: A. INSURE THERE IS NO FREIGHT HANDLING DAMAGE which should be charged against the carrier. B. Insure the manuals are in the pocket provided inside the unit. C. Review the manuals for safety and operating procedures.
ページ9に含まれる内容の要旨
LIGHT TOWER MODEL CODING SYSTEM IMPORTANT WHEN REQUESTING TECHNICAL HELP AND ORDERING REPLACEMENT PARTS THE MODEL AND SERIAL NUMBER ARE NECESSARY. REFER TO THE AMIDA SERIAL NUMBER TAG ON THE UNIT FOR CORRECT MODEL NUMBER AND SERIAL NUMBER. MODEL NUMBER IDENTIFICATION Samp1e: Light Tower Product Line LT5 080 D 4 MH CE Tower Series AL4000 (AL4) = 30 Foot Basic Tower with winch in cabinet AL5000 (ALS) = 30 Foot Basic Tower with in-cabinet light storage and door insulation 5000 (5) =30 F
ページ10に含まれる内容の要旨
RECOMMENDED ENGINE OIL & FUEL KUBOTA D905 DIESEL ENGINE Engine oil should be MIL-L-2104B/MIL-L-2104C or have properties of API designation of CC/SF or CD/SF. Change the type of engine oil according to the ambient operating temperature: Above 86°F SAE 30 32°F to 77°F SAE20 Below 32°F SAE10 SAE 10W-30 Use #2 diesel fuel. LISTER-PETTER LPW3/LPA3/LPW4/LPWT4 DIESEL ENGINES Engine oil should be MIL-L-2104C or have properties of API designation of CC/SF or CD/SF. Use CC grade oil for the initial break
ページ11に含まれる内容の要旨
MODEL AL5000 OPERATING INSTRUCTIONS I M P O R T A N T: READ ALL DIRECTIONS IN MANUAL CAREFULLY BEFORE OPERATING EQUIPMENT WARNING CAUTION DO NOT RAISE TOWER IN THE VICINITY OF OVERHEAD POWER LINES! O P E R A T I N G I N S T R U C T I O N S I. MOVE LIGHT TOWER TO DESIRED LOCATION KEEPING THE FOLLOWING IN MIND: A. The light tower should not be placed where those working under the light are either: 1) Forced to look into the light regularly. 2) Forced to work with their backs to the light (sha
ページ12に含まれる内容の要旨
IV. INSTALL THE FLOODLIGHTS ON THE CROSSBEAM A. Remove the light fixtures from the tower by removing detent pin and rotating the clamp to free the lights. Install them on the cross arm studs with the lens facing the ground. B. The cord on the fixture should be on the side closest to the trailer so the cord entry is beneath the fixture when the tower is raised ( this reduces moisture problems and ensures the water weep hole in the fixture is down). C. Set the vertical aim for each light fixture
ページ13に含まれる内容の要旨
IV. START THE ENGINE / GENERATOR SET A. CAUTION: Ensure the circuit breakers are turned “OFF”. This prevents the engine from starting under load and prevents electrical equipment from being subjected to improper voltage and frequency. B. Check the oil, fuel, and coolant (if liquid cooled) levels. If the fuel tank is empty, it may be necessary to bleed the fuel line after filling the tank (see engine instruction book for procedure). C. Turn the ignition switch to the “RUN” position (see diagram
ページ14に含まれる内容の要旨
Operating Procedures (cont’d) F. Pull the vertical locking-pin at the base of the pivot post (the kick-out spring should provide sufficient pressure to start the tower pivoting over). G. Let out on the winch cable to lower the tower into the cradle. H. Insert the rear tower horizontal travel-locking pin into the cradle. VII. TURN OFF FLOODLIGHTS A. If operating, turn light circuit breakers off. B. Turn engine switch to “OFF” to shut down the engine. CAUTION: Do not shut down engine prio
ページ15に含まれる内容の要旨
CRITERIA FOR REPLACEMENT OF WIRE ROPE – TEREX-AMIDA LIGHT TOWERS The wire ropes used to raise and lower the masts on a TEREX-Amida Light Tower are probably some of the most important mechanical parts used in day-to-day operation of the machinery. It is therefore very important that the cables be inspected on a frequent basis (once a month) for wear and tear, and immediately in the event of possible damage due to operator error in using the winch, or possible damage from other equipment. NORMA
ページ16に含まれる内容の要旨
NOTES 16
ページ17に含まれる内容の要旨
Model: Page: AL5000 LIGHT TOWER Title: Cable Replacement Diagram 6" Round Tube 2" Section Cable 2 Point B 3" Section 4" Section "Hat" Section Cable 1 Point B Cable 2 (109070) Point A Cable 1 (109065) Point A Winch Tower Base Created: Revised: Document: a) d) 2-2-99 b) e) By: c) f) Spectrum 17 c Amida Industries, Inc. 1999
ページ18に含まれる内容の要旨
NOTES 18
ページ19に含まれる内容の要旨
PARTS MANUAL 19
ページ20に含まれる内容の要旨
Model: Page: AL5000 LIGHT TOWER Title: Trailer Frame/Tongue/Outriggers 160110, Battery 174160, Battery Hold-Down 182330, Battery Hold-Down Rod 114612, Outrigger 160273, Battery Cable Set 109150, Plunger Kit 124800, Trailer Frame 124470, Tongue 841430, Jack 840222, Jack Snap Ring 840221, Jack Bracket 110870, Safety Chain Created: Revised: Document: a) d) 2-2-99 b) e) By: Spectrum c) f) 20 c Amida Industries, Inc. 1999