ページ1に含まれる内容の要旨
Order No. PHAAM0905053C2
Air Conditioner
Indoor Unit Outdoor Unit
CS-CE9JKE CU-CE9JKE
CS-CE12JKE CU-CE12JKE
TABLE OF CONTENTS
PAGE PAGE
1 Safety Precautions----------------------------------------------- 3 9.1. Indoor Unit ------------------------------------------------- 19
2 Specifications ----------------------------------------------------- 5 9.2. Outdoor Unit----------------------------------------------- 20
3Features ------------------------------------------------------------11 10 Printed
ページ2に含まれる内容の要旨
12.7. Indication Panel------------------------------------------- 33 13 Protection Control ---------------------------------------------- 34 13.1. Protection Control For All Operations--------------- 34 13.2. Protection Control For Cooling & Soft Dry Operation--------------------------------------------------- 36 13.3. Protection Control For Heating Operation --------- 37 14 Servicing Mode -------------------------------------------------- 38 14.1. Auto OFF/ON Button ----------------------------
ページ3に含まれる内容の要旨
1 Safety Precautions • Read the following “SAFETY PRECAUTIONS” carefully before perform any servicing. � Electrical work must be installed or serviced by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model installed. � The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below. Incorrect installation or servicing due to ignoring of the instruction wil
ページ4に含まれる内容の要旨
18. For R410A models, when connecting the piping, do not use any existing (R22) pipes and flare nuts. Using such same may cause abnormally high pressure in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A materials. Thickness of copper pipes used with R410A must be more than 0.8mm. Never use copper pipes thinner than 0.8mm. It is desirable that the amount of residual oil is less than 40 mg/10m. 19. During installation, install the refrigerant piping
ページ5に含まれる内容の要旨
2 Specifications INDOOR CS-CE9JKE MODEL OUTDOOR CU-CE9JKE Performance Test Condition EUROVENT Phase, Hz Single, 50 Power Supply V 230 Min. Mid. Max. kW 0.60 2.60 3.00 Capacity BTU/h — — — Kcal/h 520 2240 2580 Running Current A — 2.8 — Input Power W 125 590 750 Annual Consumption kWh — 295 — W/W 4.80 4.41 4.00 EER Kcal/hW 4.16 3.80 3.44 Power Factor % — 92 — dB-A 39 / 25 Indoor Noise (H / L) Power Level dB 55 / 42 dB-A 46 / - Outdoor Noise (H / L) Power Level dB 61 / - kW 0.60 3.60 5.00 Capacity
ページ6に含まれる内容の要旨
INDOOR CS-CE9JKE MODEL OUTDOOR CU-CE9JKE Type Propeller Fan Material PP Motor Type DC Type (8-poles) Input Power W — Output Power W 40 Cool rpm 800 Speed Hi Heat rpm 790 Moisture Removal L/h (Pt/h) 1.6 (3.4) 3 3 Cool/Fan 5.4 (190) m /min (ft /min) Lo 3 3 Heat 6.4 (230) m /min (ft /min) 3 3 Cool/Fan 8.0 (280) m /min (ft /min) Indoor Airflow Me 3 3 Heat 9.3 (330) m /min (ft /min) 3 3 Cool/Fan 11.3 (400) m /min (ft /min) Hi 3 3 Heat 11.9 (420) m /min (ft /min) 3 3 Cool 29.8 (1050) m /min (ft /min)
ページ7に含まれる内容の要旨
INDOOR CS-CE9JKE MODEL OUTDOOR CU-CE9JKE Dry Bulb Wet Bulb Maximum 32 23 Cooling Minimum 16 11 Indoor Operation Range Maximum 30 — Heating Minimum 16 — Maximum 43 26 Cooling Minimum 16 11 Outdoor Operation Range Maximum 24 18 Heating Minimum -15 -6 1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based o
ページ8に含まれる内容の要旨
INDOOR CS-CE12JKE MODEL OUTDOOR CU-CE12JKE Performance Test Condition EUROVENT Phase, Hz Single, 50 Power Supply V 230 Min. Mid. Max. kW 0.60 3.50 4.00 Capacity BTU/h — — — Kcal/h 520 3010 3440 Running Current A — 4.4 — Input Power W 125 915 1.18k Annual Consumption kWh — 458 — W/W 4.80 3.83 3.39 EER Kcal/hW 4.16 3.29 2.92 Power Factor % — 90 — dB-A 42 / 28 Indoor Noise (H / L) Power Level dB 58 / 45 dB-A 48 / - Outdoor Noise (H / L) Power Level dB 63 / - kW 0.60 4.80 6.50 Capacity BTU/h — — — K
ページ9に含まれる内容の要旨
INDOOR CS-CE12JKE MODEL OUTDOOR CU-CE12JKE Type Propeller Fan Material PP Motor Type DC Type (8-poles) Input Power W — Output Power W 40 Cool rpm 840 Speed Hi Heat rpm 820 Moisture Removal L/h (Pt/h) 2.0 (4.2) 3 3 Cool/Fan 6.3 (220) m /min (ft /min) Lo 3 3 Heat 9.4 (332) m /min (ft /min) 3 3 Cool/Fan 8.5 (300) m /min (ft /min) Indoor Airflow Me 3 3 Heat 11.0 (389) m /min (ft /min) 3 3 Cool/Fan 12.5 (440) m /min (ft /min) Hi 3 3 Heat 12.8 (450) m /min (ft /min) 3 3 Cool 31.0 (1090) m /min (ft /mi
ページ10に含まれる内容の要旨
INDOOR CS-CE12JKE MODEL OUTDOOR CU-CE12JKE Dry Bulb Wet Bulb Maximum 32 23 Cooling Minimum 16 11 Indoor Operation Range Maximum 30 — Heating Minimum 16 — Maximum 43 26 Cooling Minimum 16 11 Outdoor Operation Range Maximum 24 18 Heating Minimum -15 -6 1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based
ページ11に含まれる内容の要旨
3 Features • Inverter Technology - Wider output power range - Energy saving - More precise temperature control � Environment Protection - Non-ozone depletion substances refrigerant (R410A) � Long Installation Piping - Long piping up to 15 meters during single split connection only � Easy to use remote control � Quality Improvement - Random auto restart after power failure for safety restart operation - Gas leakage protection - Prevent compressor reverse cycle - Inner protector to protect Compres
ページ12に含まれる内容の要旨
4 Location of Controls and Components 4.1. Indoor Unit 4.2. Outdoor Unit 4.3. Remote Control 12
ページ13に含まれる内容の要旨
5 Dimensions 5.1. Indoor Unit 13
ページ14に含まれる内容の要旨
5.2. Outdoor Unit 14
ページ15に含まれる内容の要旨
6 Refrigeration Cycle Diagram 15
ページ16に含まれる内容の要旨
7 Block Diagram 16
ページ17に含まれる内容の要旨
8 Wiring Connection Diagram 8.1. Indoor Unit 17
ページ18に含まれる内容の要旨
8.2. Outdoor Unit 18
ページ19に含まれる内容の要旨
9 Electronic Circuit Diagram 9.1. Indoor Unit 19
ページ20に含まれる内容の要旨
9.2. Outdoor Unit 20