ページ1に含まれる内容の要旨
Model # AC-G0002
3500 Surge Watts / 3000 Running Watts
PORTABLE GENERATOR
INSTRUCTION MANUAL
Thank you for purchasing this high quality ACDelco Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator. This manual
provides important information on properly operating and maintaining this ACDelco Model AC-G0002 3500 Surge Watts / 3000 Running Watts
Portable Generator. Every effort has been made to ensure the accuracy of this m
ページ2に含まれる内容の要旨
ACDelco Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator FEATURES: • 3500 Surge Output • 3000 Running Watts • 120/240 Volt Operation • 6.5 HP Engine, 4 Stroke OHV • Air Cooled • 4 Gal. Fuel Tank w/Gauge • AVR Automatic Voltage Regulation • Recoil Start • Low Oil Shut Off • Spark Arrestor • UL Listed Electrical Components • MTL Approved • Full Power Panel • Engine Shut Off Switch • 120/240V Dual Voltmeter • Circuit Breaker & Power Outlets • 1
ページ3に含まれる内容の要旨
TABLE OF CONTENTS RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS.................................................................................................... 4 IMPORTANT SAFETY INSTRUCTIONS................................................................................................................................. 5 PACKAGE CONTENTS...........................................................................................................................................................
ページ4に含まれる内容の要旨
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS What You Need to Know About Safety Instructions Warning and Important Safety Instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur. Common sense, caution and care must be exercised when operating or cleaning tools and equipment. Always contact your dealer, distributor, service agent or manufacturer about problems or conditions you do not understand. This is the safety ale
ページ5に含まれる内容の要旨
Notice Regarding Emissions: Engines certified to comply with California and U.S. EPA emission regulations for SORE (Small Off Road Equipment) are certified to operate on regular unleaded gasoline and may include the following emission control systems: Three-Way Catalyst (TWC) (if equipped), and Engine Modifications (EM). Legal Requirements: Federal and/or State Occupational Safety and Health Administration (OSHA) regulations, local codes, and/or ordinances may apply to the intended use o
ページ6に含まれる内容の要旨
Powerful Voltage: This generator produces powerful voltage, which can result in electrocution. • ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). • Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER connect a building electrical system to this generator without a qualified electrician. Such connections must isola
ページ7に含まれる内容の要旨
Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator 7
ページ8に含まれる内容の要旨
In addition to the previously described safety information, familiarize yourself with all safety and hazard placards on this generator. – Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator 8
ページ9に含まれる内容の要旨
PACKAGE CONTENTS The following items are supplied with this ACDelco Model AC-G0002 3500 Surge Watts / 3000 Running Watts Portable Generator. Verify that all items are included. STOP! If there are missing items, call 1-866-460-9437, Monday - Friday, 8 AM - 4 PM Central Time for customer service. DO NOT RETURN THIS GENERATOR TO THE RETAILER. Item List: NEMA L14-30 plug for connecting 240 Volt electrical devices Set of 2 DC connector wires for connecting 12 Volt automotiv
ページ10に含まれる内容の要旨
GENERATOR COMPONENTS Observe the locations and functions of the various components and controls of this generator. (1) 120/240 Volt AC Outlet - Used for connecting electrical devices (8) Engine Switch - Used for starting/stopping the engine. that run on 120 and/or 240 Volt, 60 Hz, single phase, AC current. (9) Recoil Starter - Pull-cord for starting the engine. (2) Ground Terminal - Used for connecting grounding wires to (10) Fuel Filter Cup - Traps dirt and water from the fuel prior
ページ11に含まれる内容の要旨
PREPARING THE GENERATOR FOR USE Using this Generator for the First-Time STOP! The following section describes the required steps for preparing this generator for the first use. Failure to correctly perform these steps can damage this generator and/or shorten its life. If still unsure about how to perform any of these steps after reading this section, call 1-866-460-9437 Monday - Friday, 8 AM - 4 PM Central Time for customer service. If this generator is being used for the fi
ページ12に含まれる内容の要旨
Step 2 - Add Gasoline Gasoline and gasoline fumes are highly flammable and explosive. Handling fuel can result in serious injury or burns. • Do not fill the fuel tank near a heat, sparks or an open flame. Keep gasoline away from appliance pilot lights, barbecues, electric appliances, power tools, etc. • Do not overfill the fuel tank. Always check for fuel spills and immediately wipe them up. Spilled fuel is a
ページ13に含まれる内容の要旨
Step 3 - Ground the Generator Failure to properly ground this generator can result in electrocution. Ground this generator by tightening the grounding nut against a grounding wire as illustrated in Figure 3. A No. 12 AWG (American Wire Gauge) stranded copper wire is generally an acceptable grounding wire. The other end of this grounding wire should be connected to a copper or brass grounding rod that is dr
ページ14に含まれる内容の要旨
Step 2 - Verify Gas Level Before starting this generator, verify that there is sufficient gasoline in the fuel tank. The fuel gauge, located on the top of this generator, indicates the gas level currently in the fuel tank. If necessary, add fresh unleaded gasoline with an octane rating of 87 or higher according to “Step 2 - Add Gasoline” of the “Using this Generator for the First Time” section of this manual. Model AC-G0002 Fuel Tank Capacity (gals /L) 4 / 15 Model AC-G0002 Fuel Type Fr
ページ15に含まれる内容の要旨
6. Slowly pull on the recoil starter handle, shown in Figure 6, until a slight resistance is felt. Then pull briskly to start the engine. Gently return the cord into the generator to avoid damage to the starter or housing. Never allow the cord to snap back. 7. If the engine fails to start, repeat step 6. NOTE: After repeated attempts to start the engine, consult the troubleshooting guide before attempting again. If problems persist, call 1-866-460-9437, Monday - Friday, 8 AM - 4 PM Central Ti
ページ16に含まれる内容の要旨
The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself. To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected devices exceeds the rated wattage of the generator, D
ページ17に含まれる内容の要旨
Connect only electrical devices that are in good working order. Faulty devices or power cords present the risk of electrical shock. Immediately turn off and disconnect any device that commences to operate abnormally, sluggish or abruptly stops. Determine if the problem was the device or the rated load capacity of this generator has been exceeded. NOTE: Plug appliances into the correct outlet. Connect standar
ページ18に含まれる内容の要旨
SOME NOTES ABOUT POWER CORDS Long or thin cords can require more wattage from a generator to power an electrical device. Figure 9 shows the recommended cords according to the power requirement of the electrical device. When using cords that exceed these specifications, allow for the electrical device to have a slightly higher rated wattage requirement. Device Requirements Max. Cord Length (ft) by Wire Gauge Amps Watts (120V) Watts (240V) #8 wire #10 wire #12 wire #14 wire #16 wire 2.5
ページ19に含まれる内容の要旨
STOPPING THE GENERATOR To stop this generator: 1. Turn off all connected electrical devices and then unplug them. 2. Switch the circuit breaker to the “off” position. 3. Allow this generator to run for several more minutes with no electrical devices connected to help stabilize the temperature of this generator. 4. Set the engine switch to the “off” position. 5. Turn the fuel valve to the “off” position.
ページ20に含まれる内容の要旨
Cleaning the Generator Always try to use this generator in a cool dry place. If this generator becomes dirty, the exterior can be cleaned with a damp cloth, soft brush, vacuum and/or pressurized air. Never clean this generator with a bucket of water and/or a hose as water can get inside and cause a short circuit or corrosion. Never use gasoline to clean parts of this generator. Checking the Oil Level Even though this generator is equipped with an automatic shutoff to protect it