CW-A121VR
7 OperatingInstructions
7.1. MainUnit
7.1.2. VentilationLever.
7.1.1. VerticalAirflowDirectionVane.
When theslideleverisinthe:
AirflowdirectionadjustmentUp-and-Down.
• OPENposition,the ventilation door is
• Theverticalairflowdirectionvanemay
openedtoallowair,smokeand odors to
be positioned to deflect the air
beexpelledfromtheroom.
upwards,downwardsorstraighton.
• CLOSEposition,the ventilation door is
closed and the air inside the room is
circulatedandconditioned.
7.1.3. MainCont
ページ2に含まれる内容の要旨
CW-A121VR 7.2. How to Operate (1) OpentheControlPanelCover. Fig.1 (2) PowerSupply SwitchoffthebreakerandsettheMainControlKnobtothe OFF position before plugging the power plug into an electricaloutlet. Fig.2 (3) MainControlKnob Set to LOW COOLING or HIGH COOLING and LOW HEATING or HIGH HEATING as desired. (FAN setting operatesthefanonly.) Caution: If the Main Control Knob is turned off or changed to a fan setting from a cooling operation Fig.3 setting,WAIT at least 3 minutes before resetting to c
ページ3に含まれる内容の要旨
CW-A121VR 8 Installation Instructions 8.1. Choosing the Installation Location · When installing, use the nearest power outlet. Make sure the power outlet is easy to reach so you can quickly disconnect your air conditioner in case of emergency. · Ensure that the air conditioner is well supported, securely fastened, easily reachable and not obstructed. · Avoid locations with: salty or sulphurous air, draughts, dampness and flammable gas. · If you install the drainage system, be sure to channel
ページ4に含まれる内容の要旨
CW-A121VR · Slide the chassis into the cabinet. · Attach the air filter to the front grille. · Reinstall the cabinet screws. Secure the cabinet to chassis by using screws (from rear cabinet). · Slide the front intake grille slightly to the right to reattach the tabs and then push it down to close tight Depending upon the location of the AC outlet, route the AC cord to either the left or right side while installing the front grille. · Place the front grille on the cabinet first. Secure the fr
ページ5に含まれる内容の要旨
CW-A121VR 8.3.2. Remove the Front Grille. 8.3.3. Condensed water drainage · Remove the front intake grille In order to drain off the condensed water, it is recommended Pull up the front intake grille about 90° and slide it slightly to that you install a drain pan using the following procedure. the left to unhook the tabs. · Slide the chassis out from the cabinet. · Install the drain pan. Caution: Do not raise the front intake grille anyhigher than 90°to the unit or damage to the tabs mayoccur
ページ6に含まれる内容の要旨
CW-A121VR · Obstacles placed in front of the air outlet on the rear side of 8.4. Electric Work the unit (outdoor), or covers placed over it will cause · Always use at the rated voltage and with a specific air excessive noise and deterioration in performance. conditioning circuit. · Some installation locations may require the installation of a short-circuit breaker. · A 16 Ampere time delay fuse or circuit breaker is required. · Nominal cross sectional area of power supply wire must be 2 3 c