Henny Penny Model CMC/CMR-103,104,105,106,107
SECTION 3. OPERATION
3-1. INTRODUCTION This section provides explanations of all controls, along
with operating procedures and daily maintenance. Read the
Introduction, Installation and Opeation Sections before
operating the unit.
Wait at least 4 hours before plugging the unit into an
electrical supply. The gases and oils in the refrigeration
system needs to settle before operating the compressor, or
damage to the compressor could result.
3-
ページ2に含まれる内容の要旨
Henny Penny Model CMC/CMR-103,104,105,106,107 3-2. OPERATING CONTROLS (Continued) 3 2 1 Figure 3-1 4 5 303 3-2
ページ3に含まれる内容の要旨
Henny Penny Model CMC/CMR-103,104,105,106,107 3-3. BASIC OPERATION 1. Turn power switch to ON position. 2. Wait for temperature to reach operating temperature, 34 to 38° F (1.1 to 3.3° C). 3. Place chilled product into case. Do not block the air return and air discharge vents with product. Product temperatures may become unsafe, and increase operating costs. Do not use mechanical devices or other means to quicken the defrosting process, other than those recommended by the manufacturer, or
ページ4に含まれる内容の要旨
Henny Penny Model CMC/CMR-103,104,105,106,107 3-4. CLEANING Every 3 Months: (Continued) 1. Remove all electrical power supplied to the unit by unplugging the power cord from the wall, or by turning off the wall circuit breaker. 2. Remove all product from the unit. 3. Remove the riser and trays from the unit and clean with soap and water at a sink. 4. Clean interior surfaces with a soft cloth, soap and water. Do not use steel wool, other abrasive cleaners or cleaners/sanitizers
ページ5に含まれる内容の要旨
Henny Penny Model CMC/CMR-103,104,105,106,107 3-5. PROGRAMMING 1. Press and hold for 4 seconds. The “DEF/SET” light flashes in display. Temperature Setpoint 2. Press the or to change the temperature setpoint, within 5 seconds. After 5 seconds, the last entered setpoint stays in memory. Other Parameters 3. Press to access the other parameters. Each press of the accesses the next parameter. The parameters are: d: differential (-15...15 range) LS: lower set; lower user
ページ6に含まれる内容の要旨
Henny Penny Model CMC/CMR-103,104,105,106,107 3-5. PROGRAMMING dS: defrost system (computation); dF=digifrost Feature; Continued defrost start time based on total compressor running time rt=real time; defrost start frequency, based on real time dI: defrost interval; defrost frequency in hours, based on the selection of “dS” dE: defrost endurance; total (maximum) length of a defrost cycle, expressed in minutes. (1...99 range) dL: display lock; temperature display is locked
ページ7に含まれる内容の要旨
Henny Penny Model CMC/CMR-103,104,105,106,107 3-6. FLUORESCENT BULB UL Units REPLACEMENT 1. Pull the bulb out of the sockets. 2. Remove the bulb guard caps. 3. Install new fluorescent bulb in reverse order. CE Units 1. Remove the bulb cover. 2. Rotate the bulb. 3. Pull the lamp out of the sockets. 4. Install new fluorescent lamp in reverse order. 3-7 1102