ページ1に含まれる内容の要旨
All about the
Installation
of your
Split Type Room Air Conditioner
Model(indoor/outdoor):
FRS09PYW1/FRS09PYC1
FRS12PYW1/FRS12PYC1
FRS184YW2/FRS184YC2
FRS18PYW2/FRS18PYC2
FRS224YW2/FRS224YC2
FRS22PYW2/FRS22PYC2
www.frigidaire.com USA 1-866-942-1567 www.frigidaire.ca Canada 1-866-942-1567
ページ2に含まれる内容の要旨
Safety precautions This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. DANGER! Avoid Serious Injury CAUTION! Avoid Injury or or Death damage to the unit or other property 1. Do not attempt to install the split air conditioner by yourself. 1. Provide occasional ventilation 2. This air conditioner contains no during use. Do not direct airflow at user-serviceab
ページ3に含まれる内容の要旨
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications. 1. Connect with the power properly. Otherwise, it may cause electric shock or fire due to excess heat generation. 2. Always ensure effective grounding. No grounding may cause electric shock. 3. Disconnect the power if strange sounds, smell,
ページ4に含まれる内容の要旨
11.Do not open the unit during operation. It may cause electric shock or injury. 12.Do not drink water drained from air conditioner. It contains contaminants and could make you sick. 13.Do not disassemble or modify unit. It may cause failure of appliance and electric shock. 14.When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. 15.When the unit is to be cleaned, switch off, and turn off the circuit breaker. Do not clean unit when po
ページ5に含まれる内容の要旨
Choosing the installation site Installation Warnings 1. Carefully read the installation manual before beginning. 2. Follow each step as shown. 3. Observe all local, state and national electric codes. This appliance must be installed by a qualified licensed HVAC technician in accordance with all applicable codes. All electrical connections should be performed by a licensed electrician. 4. Pay attention to danger and safety notices Precautions for Installation Installation a
ページ6に含まれる内容の要旨
Indoor Unit inside wall, always leaving a space of 1. The unit must be installed at a site that does not obstruct the flow of at least 6" between the top of the air. indoor unit and the ceiling. 2. The site must support the weight of 8. The site must allow for the easy the indoor unit. removal of the connector pipe and 3. The site must be easily accessible drain hose. for maintenance and replacement 9. The unit must be installed at a site of the air filter. protected from direct su
ページ7に含まれる内容の要旨
ページ8に含まれる内容の要旨
1 More than 6" 3 Indoor unit More than 6" 6 More than 6" Air filter 4 5 More than 1.65' More than 1' A More 8 than 1.65' 7 6 B C More than 6.6' Outdoor unit 2 Attention 1. This illustration is for explanation purposes only. 2. Copper tubes must be insulated independently Parts list 10
ページ9に含まれる内容の要旨
Indoor unit installation Installation plates and dimensions 6" or more from Installation plate the ceiling Indoor unit outline 6" or more 6" or more from the wall from the wall Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (right) Ø 2.56" 3.39" 3.39" A < 12000 Btu's (A:33.31" B:10.83") 6" or more from the ceiling Installation plate A Indoor unit outline 6" or more 6" or more from the wall from the wall Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (right) Ø
ページ10に含まれる内容の要旨
6" or more from the ceiling Installation plate A Indoor unit outline 6" or more from the wall 6" or more from the wall 1.97'' 1.97'' Refrigerant pipe Refrigerant pipe hole (right) Ø 2.56" hole (right) Ø 2.56" 3.94'' 4.88'' =21500 Btu's (A:39.69" B:12.40") Fixing the Installation Plate 1. Install the installation plate horizontally over the structural Attention parts on the wall using the spaces indicated on the plate, as shown Fit the Installation Plate and drill holes in the figure
ページ11に含まれる内容の要旨
Connective pipe and drainage installation Connective pipe Pipe cover Pipe Pipe cover (right) holder (left) 1. For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover Left piping must be kept as it may be used when relocating the air conditioner to any other place. Rear left Rear right Right piping piping piping 2. For the rear-right-hand and rear-left- Connective hand piping, install the piping as Indoor unit pipe outline shown in the sideward fig
ページ12に含まれる内容の要旨
3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping. 4. Push the lower part of the indoor unit up on the wall, Then move the indoor unit from side to side, up and down to check if it is Cushioning hooked securely. material Piping and wrapping Ponding box 1. Bundle the tubing, connecting Indoor unit cable, and drain hose with tape securely and evenly as shown Cable Pipe room in the sid
ページ13に含まれる内容の要旨
Outdoor unit installation 1. Install the outdoor part of the unit on a rigid surface to avoid excess noise and vibration. 2. Direct the air vent toward an area without obstacles. 3. Install the unit at the site where it is exposed to as little wind as possible, especially in areas where it is frequently windy. 4. If the installation site is exposed to heavy winds, such as in coastal areas, place the unit along the widest part of the wall or use protective plates. 5. Be sure there
ページ14に含まれる内容の要旨
Air inlet Settlement of outdoor unit Anchor the outdoor unit tightly and horizontally on a concrete or rigid Air inlet mount with a bolt and nut 0.39" or 0.32" diameter (Purchased separately). Air outlet A ft) B( ft) Outdoor unit dimension ft(WxHxD) 1 ' ' Condensate drainage of outdoor unit (no for cooling only) The condensate and defrosting water formd during heating in the outdoor unit can be properly discharged by drainage pipe . Installation method:Insert the drain connect
ページ15に含まれる内容の要旨
Refrigerant piping connection Unit comes with 16.4' tubing bundle. It is not recommended to cut. If too long, loop for excess. Note: Keep original bend so not kinking of the tube occurs. Flaring work Main cause for refrigerant leakage is Pipe due to defect in the flaring work. Carry out correct flaring work using the following procedure: 1. Cut the pipes and the cable. A) Use the piping kit accessory or Correct Wrong pipes purchased locally. Oblique Roughness Burr B) Measure the distance be
ページ16に含まれる内容の要旨
4. Flaring work. Firmly hold copper pipe in a Bar die in the dimension shown in Copper pipe the table below. Handle A (inch) OUTER DIAMETER (inch) Yoke Min. Max. Red arrow mark 0.028 1/4 0.051 0.039 3/8 0.063 0.039 1/2 0.071 Clamp 0.087 5/8 0.095 handle Connection Adjustment 1. Align the pipes to be connected. Caution: Excessive twisting may 2. Screw the flare nut with your break the nut, depending on the fingers, and then tighten it with installation conditions. a spanner and torque wren
ページ17に含まれる内容の要旨
Power voltage should meet the requirements in the following table. 3. Over current protection and circuit disconnect should meet the requirements in the following table and the applicable local and national electrical codes. Electrical Data Table System Operating Compressor Outdoor Fan Indoor Fan Max. Fuse/Circuit MIN. Circuit Capacity Voltage Voltage Ampacity Breaker (BTU) Volts-Ph.- Output Output (MCA) Amps(MOCP) (Min/Max) RLA LRA FLA HP Volts FLA HP Freq Watts Watts 9K
ページ18に含まれる内容の要旨
1.57" 0.39" Connect the cable to the indoor unit Electrical box cover 1. The inside and outside connecting cable can be connected without removing the front grille. 2. Connecting cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed flexible cord, type designation 16AWG or heavier cord. 3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw. 4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the
ページ19に含まれる内容の要旨
1.
ページ20に含まれる内容の要旨
Caution After the confirmation of the above conditions, prepare the wiring as follows: 1. Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover. 2. The screws which fasten the wiring in the casing of electrical fittings are liable to come loose from vibrations to which the unit is subjected during the course of transportation. Check them and make sure that they