ページ1に含まれる内容の要旨
E
V
O
T
S
C
S
O
E
M
T
UNITED STATES STOVE COMPANY
S C
U S
“Keeping North America Warm Since 1869”
4 3 2 1
King Pellet Stove
REVISION HISTORY
REV DESCRIPTION DATE BY
model 5510 A 8/18/2008
B B
A A
DESCRIPTION SCALE SIZE REV
HOLES
TOLERANCES
UNITED STATES STOVE COMPANY
` .005" ASSEMBLY
B A
EXCEPT DWN BY
Owner’s Manual ESTABLISHED 1869
DECIMAL FINISH
.XX = 0.03 XXX = 0.010
TITLE NUMBER SHEET
AS
DATE
ANGULAR
REFERENCE 1 OF 1
NOTED KING PELLET STOVE 5510
` 2 ~ 5510
Please read this ent
ページ2に含まれる内容の要旨
Table of Contents TABLE OF CONTENTS ..............................................................................................2 SAFET Pr y ECAu Ti ONS ...........................................................................................3 SPECi Fi CATi ONS .......................................................................................................4 Heating Specifications .....................................................................................4 Dimensions ...
ページ3に含まれる内容の要旨
Safety Precautions I M P O R T A N T : R e a d t h i s e n t i r e m a n u a l b e f o r e i n s t a l l i n g A l l o w t h e s t o v e t o c o o l b e f o r e p e r f o r m i n g a n y a n d o p e r a t i n g t h i s p r o d u c t . F a i l u r e t o d o s o m a y maintenance or cleaning. Ashes must be disposed r e s u l t i n p r o p e r t y d a m a g e , b o d i l y i n j u r y , o r e v e n d e a t h . in a
ページ4に含まれる内容の要旨
Specifications Heating Specifications 1 Heat Output 48,000 BTU/hr . 2 Heating Capacity 800 - 2,000 sq. ft. 3 Fuel Burn Rate 2.0 - 6.0 lbs./hr . Burn T ime (lowest setting) 60 hrs. Hopper Capacity 150 lbs. 1 BTU output will vary depending on the quality of fuel. Use PFI listed fuels for the best results. 2 Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature. 3 Pellet size may ef fect the actual
ページ5に含まれる内容の要旨
Installation iNSTALLAT i ON OPTi ONS Read this entire manual before you install and use your Pellet stove. Failure to follow instructions may result in property damage, bodily injury, or even death! (See specific installation details for clearances and other installation requirements) A Freestanding Unit—suppo rted by pedestal/legs and placed on a non-combu stible floor surface in compliance with clearance requirements for a freestanding stove installation. A n Alcove
ページ6に含まれる内容の要旨
Installation CLEAr ANCES Y o u r K i n g s t o v e h a s b e e n t e s t e d a n d l i s t e d f o r i n s t a l l a t i o n i n r e s i d e n t i a l , m o b i l e h o m e , a n d a l c o v e a p p l i c a t i o n s i n accordance with the clearances given in FIGURES 3-5 and T ABLE 1. NOTE: Distance “C” on the left-hand side of your King stove may need to be greater than the minimum required clearance for suitable access to the control panel. Figur E 3 Figu
ページ7に含まれる内容の要旨
Installation vENT i Ng r Equir EMENTS Install vent at clearances specified by the vent manufacturer. Do not connect the pellet vent to a vent serving any other appliance or stove. Do not install a flue damper in the exhaust venting system of this unit. The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes. IMPORTANT! This unit is equipped with a negative draft
ページ8に含まれる内容の要旨
Installation vENT TEr Mi NATi ON CLEAr ANCES: A) Minimum 4-foot clearance below or beside any door or window that opens. B) Minimum 1-foot clearance above any door or window that opens. C) Minimum 3-foot clearance from any adjacent building. D) Minimum 7-foot clearance from any grade when adjacent to public walkways. E) Minimum 2-foot clearance above any grass, plants, or other combustible materials. F) Minimum 3-foot clearance from an forced air intake of any appliance. G) Mini
ページ9に含まれる内容の要旨
Installation Thr Ough Th E w ALL i NSTALLATi ON (RECOMMENDED INST ALLA TION ) T o vent the unit through the wall, connect the pipe adapter to the exhaust motor adapter . If the exhaust adapter is at least 18-inches above ground level, a straight section of pellet vent pipe can be used through the wall. Y our King dealer should be able to provide you with a kit that will handle most of this installation, which will include a wall
ページ10に含まれる内容の要旨
Installation Ou TSid E Air Su PPLy (optional) Depending on your location and home construction, outside air may be necessary for optimal performance. Metal pipe (solid or flexible) must be used for the outside air installation. PVC pipe is NOT approved and should NEVER be used. A wind shield over the termination of the outside air pipe or a 90-degree elbow or bend away from the prevailing winds MUST be used when an outside
ページ11に含まれる内容の要旨
Understanding your stove How your stove works Y our King stove utilizes a inclined auge r fuel feed system that is operated by a microprocessor controlled digital circuit board. The digital circuit board allows the inclined auger fuel feed system to run in a timer-based, non-continuous cycle; this cycling allo ws the auger to run for a predetermined period of seconds. The auger pushes pellets up a chute located at th
ページ12に含まれる内容の要旨
Control Panel Overview T urning the heater ON/OFF , as well as adjustments for the fuel feed rate and room fan speed are performed by pressing the appropriate button(s) on the control panel which is located on the lower left-hand side of your heater . This unit can be changed between an automatic operation or a manual operation. The controller comes default in the automatic mode. ON/OFF • Pressing the “ON” button on t
ページ13に含まれる内容の要旨
Operation u Ni T Pr EPAr ATi ON A f t e r c a r e f u l l y u n p a c k i n g a n d r e a d i n g t h e i n s t r u c t i o n s f o r i n s t a l l i n g y o u r s t o v e , y o u w i l l n e e d t o p e r f o r m t h e f o l l o w i n g s t e p s : Attach the included spring handle to the door handle by screwing it on in a respective location. • Attach the electrical cord to the back of the stove first; then plug it into a 1 10-vol
ページ14に含まれる内容の要旨
Operation STAr T-u P Pr OCEdur E Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. Keep all such liquids well away from the stove while it is in use. V erify that the hopper is clean and free of foreign matter . 1.) V erify that all of the required exhaust/inlet connections have been made in accordance with this manual and that 2.) the stove is plugged into an ou
ページ15に含まれる内容の要旨
Operation d Ai Ly OPEr ATi ON The hopper and stove top will be hot during operation; therefore, you should always use some type of hand protection when refueling your stove. Never place your hand near the auger while the stove is in operation. This unit should be filled when the hopper level drops below 3-inches. In the event of a power outage, the stove WILL NOT function. It is very important that unit be vented properly (with outside air), as
ページ16に含まれる内容の要旨
Maintenance iNTE ri Or Ch AMBEr S Periodically remove and clean the burnpot and the area inside the burnpot housing. In particular it is advisable to clean o u t t h e h o l e s i n t h e b u r n p o t t o r e m o v e a n y b u i l d u p t h a t m a y p r e v e n t a i r f r o m m o v i n g t h r o u g h t h e b u r n p o t f r e e l y . R e m o v e the two(2) plates on each side of the burnpot housing and clean out th
ページ17に含まれる内容の要旨
Trouble Shooting Disconnect the power cord before performing any maintenance! NOTE: Turning the ON/OFF Switch to ”OFF” does not disconnect all power to the electrical components of the stove. Never try to repair or replace any part of the stove unless instructions for doing so are given in this manual. All other work should be done by a trained technician. Pr OBLEM CAu SE: T o rich air/fuel mixture O r a n g e , l a z y f l a m e _ e x c e s s i v e f u e l • Clean out the
ページ18に含まれる内容の要旨
Error Codes and Display Indicators Error Error Possible Code Descrption Causes Err1 The high limit temperature sensor • Inadequate ventilation. has tripped. • Room fan failure. • Exhaust Blockage. • Electrical Open in wiring. Err2 Stove ran out of fuel during normal • Hopper Empty . operation. • Auger output failure or jam. • Flame of fuel quality caused fire to burn too slowly or go out. • Electrical Open in wiring. Err3 T h e s t o v e w a s u n a b l e t o r e
ページ19に含まれる内容の要旨
V iewing Door Detail 10 8 9 5 1 2 3 11 12 7 4 6 Parts Diagram USSC 19
ページ20に含まれる内容の要旨
PARTS LIST 5510 Item Part No. Title Qty. Item Part No. Title Qty. 1 69524 Door Assembly 1 26 891 164 W eldment Auger Housing 1 2 891372 Hinge Pad, Threaded 2 27 891 141 Auger 1 N/S 83045A W asher , 3/8” 2 - 69513 Assy ., T op Bushing (28-30) 1 N/S 83274 3/8-16 Lock Nut 2 28 891 189 T op Bushing Plate 1 3 25080 Door Latch 1 29 891 132 Bushing 2 4 891395 Ash Pan Bed 1 30 83534 Retaining Ring 2 N/S 83508 5/16-18 Bolt 1 - 69514 Assy ., Bo