ページ1に含まれる内容の要旨
R
CLASSIC BAY 1200 PELLET STOVE
Owner’s Manual
Installation and Operation
Beaverton
Tested and
Model:
Listed by Oregon USA
C US
OMNI- Test Laboratories, Inc.
CB1200
CAUTION
DO NOT DISCARD THIS MANUAL
• Leave this manual with
• Read, understand and
• Important operating and
party responsible for use
follow these instructions
maintenance instruc-
and operation.
for safe installation and
tions included.
operation.
WARNING
WARNING
HOT! DO NOT TOUCH.
Please read this entire manual
SEVERE BU
ページ2に含まれる内容の要旨
R RR CB 1200 Pellet Stove and Welcome to the Quadra-Fire Family! meticulously fabricated and gold and nickel surfaces are Hearth & Home Technologies welcomes you to our tradi- hand-finished for lasting beauty and enjoyment. Our pledge tion of excellence! In choosing a Quadra-Fire appliance, to quality is completed as each model undergoes a quality you have our assurance of commitment to quality, durabil- control inspection. From design, to fabrication, to shipping: ity, and performanc
ページ3に含まれる内容の要旨
R RR CB 1200 Pellet Stove TABLE OF CONTENTS E. Starting Your First Fire........................ 2 Section 1: Listing and Code Approvals F. Fire Characteristics .............................2 A. Appliance Certifications ......................4 G. Feed Rate Adjustment .......................2 B. Mobile Home Approved ......................4 H. Ignition Cycles ....................................24 C. Glass Specifications ............................4 I. Frequently Asked Questions.....
ページ4に含まれる内容の要旨
R RR CB 1200 Pellet Stove Listing and Code Approvals 1 A. Appliance Certification E. BTU & Efficiency Specifications Model CB1200 Pellet Stove Emissions Rating 0. 9 grams/hr . Laboratory OMNI Test Laboratories, Inc. *BTU Output 14,000 - 40,000 / hr Report No. 061-S-21-4 Heating Capacity up to 2,500 sq. ft. Type Solid Fuel Room Heater/Pellet Type Hopper Capacity 80 lbs Standard ASTM E1509, ULC S627 and ULC/ Fuel Wood Pellets or Shelled Corn ORD-C1482 Room Heater Pellet Fuel Shipping Weight 4
ページ5に含まれる内容の要旨
R RR CB 1200 Pellet Stove Getting Started 2 A. Design, Installation & Location B. Fire Safety Considerations Maintain the designated clearances to combustibles. Insu- 1. Appliance Location lation must not touch the chimney. You must maintain the designated air space clearance around the chimney. This Consideration must be given to safety, convenience, traffic space around a chimney is necessary to allow natural heat flow, and the fact that the appliance will need a chimney and removal
ページ6に含まれる内容の要旨
R RR CB 1200 Pellet Stove C. Tools And Supplies Needed E. Inspect Appliance & Components and Pre-Use Check List Tools and building supplies normally required for installation, unless installing into an existing masonry fireplace: 1. Place the appliance in a location near the Reciprocating Saw Safety Glasses final installation area and follow the proce- Channel Locks Framing Square dures below: Hammer Electric Drill & Bits (1/4”) 2. Open the appliance and remove all the parts Phillips Scre
ページ7に含まれる内容の要旨
R RR CB 1200 Pellet Stove Dimensions and Clearances 3 A. Appliance Dimensions 4-5/8 in 8-1/6 in. (205mm) 20- 7/16 in. (519mm) (118mm) 12-/8 in (14mm) 14-1/4 in (62mm) C L 5.0 in 2-1/2 in C (127mm) L (64mm) 25-/4 in. 27-5/8 in. (654mm) (692mm) 28-1/2 in. (724mm) Figure 7.2 - Top View with Top Vent Adapter Figure 7.1 - Top View 28-1/2 in. 25-/4 in. (724mm) (629mm) 1-5/8 in. (80mm) C L 10-/4 in. 8-1/16 in. (27mm) (205mm) 24-/4 in. 26-1/2 in. (629mm) (67mm) Figure 7.3 - Side View Figur
ページ8に含まれる内容の要旨
R RR CB 1200 Pellet Stove B. Clearances to Combustibles (UL and ULC) Alcove Installation Inches Millimeters Minimum Alcove Height 44 1117 Minimum Alcove Width 40-1/2 1029 A C Maximum Alcove Depth 6 915 Minimum Alcove Side Wall 6 152 Top of Unit to Combustibles 12-1/2 18 B C WARNING Fire Risk. Inches Millimeters Straight Back Against Comply with all minimum clearances to Wall combustibles as specified. Back Wall to Appliance 2 51 A Failure to comply may cause house fire. Side Wall to Applia
ページ9に含まれる内容の要旨
R RR CB 1200 Pellet Stove C. Hearth Pad Requirements (UL and ULC) Alcove Installation Inches Millimeters Minimum Alcove Height 44 1117 Use a non-combustible floor protector, extending beneath Minimum Alcove Width 40-1/2 1029 appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass Maximum Alcove Depth 6 915 door. Minimum Alcove Side Wall 6 152 Top of Unit to Combustibles 12-1/2 18 L* K K M Figure 9.1 Inches Millimeters Hearth Pad Re
ページ10に含まれる内容の要旨
R RR CB 1200 Pellet Stove Vent Information 4 B. Venting Termination Requirements A. Chimney and Exhaust Connection 1. Chimney & Connector: Use or 4 inch (76-102mm) diameter type "L" or "PL" venting system. It can be CAUTION vented vertically or horizontally. Do not terminate vent in any enclosed or semi-enclosed 2. Mobile Home: Approved for all listed pellet vent. If using area such as a carport, garage, attic, crawl space, under a the inch (76mm) vertical top vent adapter Kit or
ページ11に含まれる内容の要旨
R RR CB 1200 Pellet Stove WARNING C. Equivalent Feet of Pipe Improper installation, adjustment, alteration, service or The table below can help you calculate the equivalent feet maintenance can cause injury or property damage. Refer of pipe which is a method used to determine pellet vent size. to the owner’s information manual provided with this appli- See Figure 11.1 ance. For assistance or additional information consult a qualified installer, service agency or your dealer. Example of 3
ページ12に含まれる内容の要旨
R RR CB 1200 Pellet Stove Venting Systems 5 A. Alcove A C D B Figure 12.1 Inches Millimeters Alcove Installation Minimum Alcove Height 44 1117 A Minimum Alcove Width 40-1/2 1029 B Maximum Alcove Depth 6 915 C Minimum Alcove Side Wall 6 152 D not shown Top of Unit to Combustibles 12-1/2 18 All minimums listed are to a combustible surface. NOTE: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY. • Illustrations/diagrams are not drawn to scale. • Actual installation
ページ13に含まれる内容の要旨
R RR CB 1200 Pellet Stove B. Through The Wall NOTE: Horizontal termination cap must be a minimum of 12 inches. In Canada, where passage through a wall or partition of (05mm) from the wall. Approved for mobile home instal- combustible construction is desired, the installation shall lations. Must use or 4 inch (76-102mm) “L” or “PL” listed conform to CAN/CSA-B65 pellet venting or listed double wall pipe and a Quadra-Fire outside air kit in mobile homes. 2 in. Straight Out (51mm) Minim
ページ14に含まれる内容の要旨
R RR CB 1200 Pellet Stove C. Vertical We recommend a minimum of 60 in. Rain Cap (1524mm) vertical, however above the eave is preferred. Both installations are approved for mobile home installations. Must use or 4 inch (76 Flashing 24 in. (610mm) to 102mm) “L” or “PL” listed pellet venting or minimum listed double wall pipe and Quadra-Fire out- side air kit in mobile homes. Single wall pipe is approved for residential installations only. Firestop Class A Chimney Connector Adapter C
ページ15に含まれる内容の要旨
R RR CB 1200 Pellet Stove WARNING Fire Hazard Inspection of Chimney: • Masonry chimney must be in good condition. • Meets minimum standard of NFPA 211 • Factory-built chimney must be 6 in. (152mm) UL10 HT. E. Masonry Fireclay Flue Concrete Cap Liner with Airspace Flashing 1 in. (25mm) Clearance with Firestop 1 in. (25mm) Clearance in. (76mm) Minimum 6 in. (152mm) Sheathing Minimum Cleanout Cover Airtight Clean-out Door Non-Combustible Hearth Pad Figure 15.1 F. Alternate Masonry Fireclay Fl
ページ16に含まれる内容の要旨
R RR CB 1200 Pellet Stove Mobile Home 6 A. Mobile Home Installation CAUTION You must use a Quadra-Fire Outside Air Kit Maintain structural integrity of mobile home: for installation in a mobile home. • Floor, wall, ceiling and/or roof. Do NOT cut through: 1. An outside air inlet must be provided for the combustion • Floor joist, wall, studs or ceiling trusses. air and must remain clear of leaves, debris, ice and/or • Any supporting material that would affect the structural snow. It must b
ページ17に含まれる内容の要旨
R RR CB 1200 Pellet Stove Appliance Set-Up 7 A. Outside Air Kit Instructions 2. Floor Installation a. Remove rear screen and set aside. Included in Kit: 1 piece of 2 inch x foot flex hose, 2 hose b. Install cover plate over hole in right rear floor. clamps, 1 collar assembly, termination cap assembly, 1 trim ring, 12 screws. c. Cut a 2 inch minimum hole in the floor to accommodate Tools Needed: Phillips head screw driver; wire cutters; flex hose. hole saw or jig saw. d. Attach hose to t
ページ18に含まれる内容の要旨
R RR CB 1200 Pellet Stove C. Rear Vent and Rear Vent to Top Vent B. Top Vent Adapter Installation Adapter Installation 3 to 3 inch Top Vent Adapter 3 to 6 inch Top Vent Offset Adapter Installing the Top Vent Adapter 1. Put a layer of high temperature silicone on the inch (76mm) exhaust outlet. 2. Slide the top vent adapter onto the rear exhaust outlet and adjust the assembly to a vertical position. . Drill 4 holes with #26 drill bit (provided) into the back of the appliance using
ページ19に含まれる内容の要旨
R RR CB 1200 Pellet Stove E. Brick Clip Installation D. Brick Set Installation 1. Remove the baffle first, follow instructions on page 32. WARNING 2. Slide bottom of left rear brick in first; rotate top edge Risk of Injury. toward rear of appliance and then rotate outer edge • Brick may have small wires protruding from toward rear of appliance, until brick slides into place. the back of brick. Figure 19.1. . Repeat with right rear brick. 1. After the brick set has been installed, 2 brick
ページ20に含まれる内容の要旨
R RR CB 1200 Pellet Stove F. Optional Log Set Placement Instructions G. Optional Gold or Nickel Grille Assembly CAUTION CAUTION Do not open top all the way back so the weight of the Logs are FRAGILE. Use extreme care when handling or top is supported by the hinges. It will damage the cleaning logs. hinges. It will be necessary to prop the top up with a supporting brace. You can use the shipping box as shown in Figure 1. 1. Place the front log in first as shown in Figure 20.1. Place