INSTALLATION AND
OPERATION INSTRUCTIONS
MONTECITO ESTATE™
TM
EPA Wood-Burning Fireplace
P/N 850,038M REV. C 04/2007
MODEL
MONTEST
This installation manual will enable you to obtain a safe, efficient and
dependable installation of your fireplace system. Please read and
understand these instructions before beginning your installation.
Do not alter or modify the fireplace or its components under any circum-
stances. Any modification or alteration of the fireplace system, including
but not l
ページ2に含まれる内容の要旨
IMPORTANT! GENERAL SAFETY WARNING WARNING PRECAUTIONS. READ AND UNDERSTAND THESE SAFETY To avoid the risk of damaging Be careful adding wood fuel to the RULES BEFORE YOUR FIRST FIRE. fireplace materials and increas- fire or handling fireplace tools such ing the risk of fire, do not use the as shovels, tongs or pokers. fireplace to cook or warm food. WARNING WARNING Never leave children unattended WARNING when there is a fire burning in Never modify or alter your fire- the f
ページ3に含まれる内容の要旨
OPTIONAL EqUIPMENT CONGRATULATIONS! Additional Equipment (optional) In selecting this LENNOX wood-burning appliance you have chosen one of the finest - Gravity Venting System fireplaces available. The Montecito Estate™ is a clean burning EPA certified fireplace - TUBINOX chimney (or PROJET SS), 7” diameter with adaptor for installation in a that is designed to provide you dependable service as well as warmth and enjoyment masonry chimney. for many years to come. Please carefully read and
ページ4に含まれる内容の要旨
The combustion air control should be opened Accelerated Combustion COMBUSTION CONTROLS before opening the doors to minimize the possi- bility of back draft coming into the room (Figure The maximum heat output for the Montecito Primary Air & Air Boost Controls 1-A) More details are available in Refueling For Estate is achieved by burning with the door Best Performance on Page 5 . closed and the combustion air opened and There is no flue damper in the Montecito Es- pulled out. Through this me
ページ5に含まれる内容の要旨
Slow Combustion The unit will burn best with 2-3 pieces of cord As the fire burns, air goes up the chimney. This wood spaced 1 to 2 inches apart and allowing air must be replaced through the outside air duct. When the air combustion control is completely air to get under the fuel. Criss-crossing or ar- When operating the Montecito Estate, open a closed, the fireplace is in a slow combustion ranging the fuel so that air can get underneath nearby window temporarily to check if there is pha
ページ6に含まれる内容の要旨
C. Do not expect chemical cleaners to keep IMPORTANT CAUTIONS DOOR FRAME FINISH CARE your chimney clean. The rain cap can be Use a glass cleaner and a soft cloth to polish A. Do not block the hot air vents to the fire- removed for inspection and/or cleaning of the casing. Do not use abrasives such as steel place as this will cause the fireplace to wool, steel pads or an abrasive polish for they the chimney. overheat. may scratch the frame’s finish. B. Never use gasoline, kerosene, charco
ページ7に含まれる内容の要旨
DOOR INSTALLATION 1 The doors must be put in place only when the installation of the Montecito Estate™ is completed. All you have to do is fit the male part of the hinge, already on the door, to the female part, which is on the fireplace. To remove the doors, simply pull them up from the hinges. The door adjustment has been set at the factory. If the fit is still not perfect, you can adjust the door using the hinge screws (See Figure 7-1 ) 2 Figure 7 GLASS CARE Glass Replacement The glass
ページ8に含まれる内容の要旨
FIREPLACE INSTALLATION Locating The Montecito Estate™ The best location to install your fireplace is determined by considering Tile or Marble the location of windows, doors, and the traffic flow in the room where the fireplace is located, allowing space in front of the unit for the hearth extension and the mantel, and taking into consideration the location of Fireplace Minimum 1” the hot air ducts (optional), outside air kit and chimney. If possible, Cement Board you should choose a locati
ページ9に含まれる内容の要旨
Insulated Chase Construction CORNER INSTALLATION Storm Roof Support Collar 29-1/2” Flashing D Attic J Radiation * Floor F Shield Ceiling Wall Header 23-3/4” E B Back Wall of Chase/Enclosure A OUTSIDE CHASE Including Finising Materials if any Fireplace Framing C Firestop 7 Ft. Min. Note: Floor 6’ 8” and wall * Zero Clearance G below the Min. From Back attic must Spacer to Wall 2” x 3” be insulated Min. using the Insulate Joists same Same As Ceiling insulation. Pl
ページ10に含まれる内容の要旨
FACING Fireplace Blower Mantel & Facing (Side View) The fireplace comes equipped with a heat acti- IMPORTANT vated blower. It is located in the bottom of the Drywall fireplace, towards the back. It uses 120 V and The facade must be removable Mantel 2” X 3” Min. must be connected to the main electrical circuit once installed. The facade is Spacer by a qualified electrician. For connection, use the designed to overlap any facing ... ....... .......... electrical box supplied with the un
ページ11に含まれる内容の要旨
Rain Cap Frame Flashing Collar Grill Flashing Roof Support Attic Radiation Shield Firestop 6-1/2” Min. (to ceiling) 68” Min. 56” Min. Non-Combustible Flameproof Facing Figure 16 When installing the double outlet system, the hot air outlets can be Figure 18 installed in the same room as the fireplace, or one or both of the outlets can be installed in adjacent or upper rooms. Installing the ducts at dif- ferent elevations will tend to exhaust more heat out of the higher outlet The duct syst
ページ12に含まれる内容の要旨
OUTSIDE AIR KIT OUTSIDE CONNECTION It is mandatory to install an outside air connection to the Montecito Estate™. The following components are required and are included with the fireplace: Outside Aluminum Tape Intake - Outside air kit (includes 40 inch flex that goes up to ten (10) feet Plastic long) Cover - 4” Adaptor for fireplace connection Screw Outside Air Installation The outside air assembly may be installed according to the following requirements: Insulation Opening Flexible Pipe
ページ13に含まれる内容の要旨
8. A rain cap must be installed on top of the chimney. Failure to install THE CHIMNEY SYSTEM a rain cap may cause corrosion problems. Chimney Installation Notes 9. Cut and frame square holes in all floors, ceilings, and roof that the 1. If possible, install an interior chimney as it will provide better per- chimney will go through to provide a 2” (50 mm) clearance between formance. In areas with continuous temperatures below 18°C (0°F), the chimney and any combustible materials. Do not fil
ページ14に含まれる内容の要旨
CHIMNEY INSTALLATION INSTRUC- S2100 / HT6000+ ACBI TIONS Solid Packed Pipe Air Cooled Pipe 1. Cut and frame the holes in the ceiling, floor Attic Radiation Shield and roof where the chimney will pass (see Figure 22). Use a plumb bob to line up the Attic Radiation center of the holes. The sizes are indicated Shield in Table 2 for the floor and ceiling holes and Table 3 (Page 15 ) for the roof holes. CHIMNEY MODEL SqUARE HOLE SIZE OPENING Secure Temp™ S2100+ Nova Temp™ HT6000+ 15
ページ15に含まれる内容の要旨
After reaching the location requiring the CHIMNEY MODEL ACBI elbow, proceed as follows: Chimney Secure Temp S2100+ / Nova Temp HT6000+ / Collar Secure Temp GX Chimneys 1. Install the first elbow; turn it in the required direction. Fasten it to the chimney with the three (3) 1/2” (12 mm) metal screws provided with the elbow. 2. Install the necessary chimney lengths to achieve the required offset. Lock the chimney lengths together: it is recommended to use three (3) 1/2” (12 mm) screw
ページ16に含まれる内容の要旨
OFFSET CHIMNEY INSTALLATION The minimum chimney height when using elbows is: Offset Dimensions B Total Height A Horizontal Offset Chimney Elbow Offset & Two Lengths Between Elbows Height 8” 12” 18” 24” 36” 8” & 36” 12” & 36” 18” & 36” 24” & 36” 36” & 36” 3” 4-1/4” 5-3/4” 7-1/4” 10-1/4” 12-1/4” 13-1/4” 14-3/4” 16-1/4” 19-1/2” A (76 mm) (108 mm) (146 mm) (184 mm) (260 mm) (311 mm) (337 mm) (375 mm) (413 mm) (495 mm) 15º 20-3/4” 24-1/4” 29-1/2” 34-3/4” 45” 51-1/4” 54-3/4” 60” 65-1/4” 75-1/2” B (527
ページ17に含まれる内容の要旨
OFFSET CHIMNEY INSTALLATION Support Straps Straps Chimney ACBI ACBI Starter Section Figure28 OFFSET CHIMNEY INSTALLATION WITH WALL PENETRATION Rain Cap Collar Roof Support Roof Flashing Outside Wall Offset Support Framing 2” x 3” Insulated Wall Radiation Shield Note: In cold areas it is recommended to protect thechimney ina insulated chase. Figure29 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 17
ページ18に含まれる内容の要旨
ANGLED WALL RADIATION SHIELD For roof support installation, refer to the instructions provided with the (XRSMI30 and AC10RSMI30) support. When traversing a combustible wall with the chimney at a 30º or 45º Universal Offset Support angle, an angled firestop or wall radiation shield must be installed. Only This support is used to support the chimney above an offset. When one is required. the chimney offset is used to traverse a wall this support may be used on the wall to support the chimney
ページ19に含まれる内容の要旨
INSTALLATION INSTRUCTIONS FOR MASONRY APPLICATION Follow these steps: 1- Position the fireplace in its location. Temporarily install the S2100+ WARNING: Before starting the installation, the masonry chimney elbow on the top of the fireplace and, using a level, mark with an oval must be inspected by a qualified chimney sweep. the location where the flue liner will enter the masonry chimney. 2- In the middle of the oval, drill a hole in the masonry chimney at 30º. The following requirements mu
ページ20に含まれる内容の要旨
OPTIONAL INSTALLATION ACCESSORIES CHIMNEY - PARTS AND COMPONENTS LISTS Installation Accessories Secure Temp GX - 2” Insulated Galvanized Chimney System (Recommended Insulated System) Description Cat./Part No. Galvanized (7” ID & 11” OD) U.S.A. ONLY Facades (Required- Order Separately) Description Cat./Part No. H4850 Montecito Estate™ Facade Black, MEFBK Lengths & Misc. Chimney Components Montecito Estate Facade Brushed Nickel, MEFBN H4851 Length 8”, 7GXL8 7GXL8 H4852 Montecito Estate Fac