Model 35558
Single Propane Stove - Manual Start
Model 35559
Double Propane Stove - Manual Start
Model 35560
Single Propane Stove - Piezo Start
Model 35561
Double Propane Stove - Piezo Start
ASSEMBLY AND OPERATING INSTRUCTIONS
®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
©
®
Copyright 2005 by Harbor Freight Tools . All rights reserved. No portion of th
ページ2に含まれる内容の要旨
PRODUCT SPECIFICATIONS Item Description Fuel Source Standard LP Gas Tank (All Models) (not included) Product Compatibility For Use With UL Approved: (All Models) Model 91357 or Model 91359 LP Regulator & Hose Kit (neither included) Model 35558 Specifications Maximum BTU Output: 15,000 each burner Ignition System: Manual (Requires Lighting w/Matches) Number of Burners: 1 Overall Dimensions: 5-1/2” H x 10-1/2” W x 13” Deep Maximum BTU Output: 15,000 each burner Model 35559 Specifi
ページ3に含まれる内容の要旨
2. Store idle equipment. When not in use, this product must be stored in a dry location to inhibit rust. Always lock up tools and keep out of reach of children. 3. Check for damaged parts. Before using any product, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for any broken parts or mounting fixtures, and any other condition that may affect proper operation. Any part that is damaged should be pr
ページ4に含まれる内容の要旨
POL (Put On Left) valve. The tank must be constructed and marked in such a way as to comply with the specifications for LP gas tanks by the U.S. Department of Transportation (DOT). 6. The use of the Propane Stove must be in conformity with local codes or, in the absence of local codes, with the standard for storage and Handling of Liquified Petroleum Gases, ANSI/NFPA 58. For Canada, the use must be in accordance with the current CAN/CGA B149.2 installation codes. CARBON MONOXIDE INHALATION HAZ
ページ5に含まれる内容の要旨
5. Keep solid combustibles such as paper or cardboard a safe distance away from the Propane Stove. Never use the Stove in spaces which do or may contain volatile or airborne combustibles, or products such as gasoline, solvents, paint thinner, dust particles or unknown chemicals. 6. Always operate the Propane Stove with the propane tank in its vertical upright position, on a non-combustible surface. While in operation, do not tilt or lean the propane tank on its side. Never turn the tank upsid
ページ6に含まれる内容の要旨
caution are factors which cannot be built into this product, but must be supplied by the operator. ASSEMBLY INSTRUCTIONS 1. WARNING! Always make sure to close the valve on the propane tank (not included) prior to assembling the Propane Stove, performing maintenance, or making any adjustments to the unit. 2. CAUTION! This product is machine manufactured. Be aware of sharp edges. Use heavy duty work gloves and ANSI approved safety impact eye goggles when assembling. 3. Turn the
ページ7に含まれる内容の要旨
7. NOTE: The propane tank used must be constructed and marked in accordance with the specifications for LP propane cylinders by the U.S. Department of Transportation. (See Figure A.) 8. To connect to the propane tank, first make sure the Temperature Control Knob (4) of the Propane Stove is in its “OFF” position. Wrap the male threads of the propane tank’s discharge pipe with about 4 inches of pipe thread seal tape. Then, screw the Gas Valve of the LP Regulator & Hose Kit firmly onto the propa
ページ8に含まれる内容の要旨
7. While cooking, avoid spills as this may result in extinguishing the flame and clogging the Burner holes. 8. Always turn the Temperature Control Knob (4) to its “OFF” position before removing a pan from the Burner (2). (See Assy. Diagram.) 9. When finished using the Propane Stove, turn the Temperature Control Knob (4) to its “OFF” position. Then, close the gas valve on the propane tank. (See Assy. Diagram.) 10. The propane tank must be stored outside. If the Propane Stove is to be stored in
ページ9に含まれる内容の要旨
combustible materials, gasoline, and other flammable vapors and liquids. 7. CAUTION: All maintenance, service, or repairs not listed in this manual are only to be attempted by a qualified service technician. Improper Flames = Yellow/Orange Flames (Yellow Flames) = Blue Flames Proper Flames FIGURE B (Yellow tips on the top of the cones) PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL
ページ10に含まれる内容の要旨
PARTS LISTS AND ASSEMBLY DIAGRAMS Model 35558 Part # Description Qty. Part # Description Qty. 1 Body 1 5 Inlet Connection Nozzle 1 2 Burner 1 6 Pipe Assembly 1 3 Grill 1 7 Rubber Foot 4 4 Temperature Control Knob 1 Model 35559 Part # Description Qty. Part # Description Qty. 1 Body 1 5 Inlet Connection Nozzle 1 2 Burner 2 6 Pipe Assembly 2 3 Grill 2 7 Rubber Foot 4 4 Temperature Control Knob 2 Model 35560 Part # Description Qty. Part # Description Qty. 1 Body 1 5 Inlet Con