ページ1に含まれる内容の要旨
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
PELLET STOVE
EF THERMO 28
TECHNICAL MANUAL
� � � �
PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE
OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY
OR EVEN DEATH.
Contact your building or fire officials about restrictions and installation
inspection require
ページ2に含まれる内容の要旨
Table of Contents Introduction........................................................................................3 Rating Label Location................................................................3 Important Safety Data...............................................................3 Safety Warnings And Recommendations.....................................3 Specifications......................................................................................5 EF Thermo Data.................
ページ3に含まれる内容の要旨
Introduction RATING LABEL LOCATION: The rating label is located on the hopper lid. IMPORTANT SAFETY DATA: Please read this entire Owner’s Manual before installing or operating this ENVIRO Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for your area. To prevent the possibility of a fire, ensu
ページ4に含まれる内容の要旨
Introduction SOOT: Operation of the stove with insufficient combustion air will result in the formation of soot which will collect on the glass, the heat exchanger, the exhaust vent system, and may stain the outside of the house. This is a dangerous situation and is inefficient. Frequently check your stove and adjust the slider/ damper as needed to ensure proper combustion. Electrical: THE USE OF A SURGE PROTECTED POWER BAR IS RECOMMENDED. The maximum power requirement is 800 watts (3.3 am
ページ5に含まれる内容の要旨
Specifications EF THERMO DATA: Necessary draught 34.8 Pa (0.348 mbar) Mass of Appliance 157 Kg Minimum required load bearing capacity of the floor 247 Kg Water content 17.3 liters Exhaust gas temperature at nominal heat output 230°C Exhaust gas temperature at minimum heat output 120°C Exhaust mass flow at nominal heat output 7.5 g/s Exhaust mass flow at minimum heat output 8.0 g/s Flue pipe diameter 80 mm Space heating output to be determined by Lab Testing KW Water heating output to be determin
ページ6に含まれる内容の要旨
Specifications APPLIANCE DIMENSIONS: UNIT DIMENSIONS HEIGHT: 37 3⁄8” (949 mm) WIDTH: 25 1⁄4” (641 mm) 7 DEPTH: 25 /16” (646 mm) 3 3 7 / 8 " ( 9 4 . 9 c m ) HEARTH PAD: WIDTH: 25 1⁄4” (641 mm) 3 DEPTH: 31 /16” (793 mm) [6” (152.4 mm) in front of unit] 7 25 / 1 6 " 1 25 / 4 " ( 6 4 . 6 c m ) ( 64. 1cm ) Figure 1 � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � �
ページ7に含まれる内容の要旨
Specifications SAFETY DEVICES: Air Bleeder Valve (shown in Figure 3): Located under unit top of the unit. � � � � � � � � � � � � � � � To remove the top follow these steps (refer to Figure 4): 1. Open hopper lid and remove the two (2) screws at the front. 2. Loosen the two (2) screws at the back of the top. 3. Remove top. 4. Replace the top by using the reverse of the method used to remove it. Refer to Figure 5 and 6 for the following safety devices. See next page to remove cabinet sides. F
ページ8に含まれる内容の要旨
Specifications To remove the cabinet sides, follow these steps: 1. Loosen the three (3) screws from both sides on the back of the appliance (see Figure 7). 2. Remove the ash drawer cover (see Figure 8). 3. Remove the four (4) screws, two on each side, under the ash drawer holding the cabinet sides on (see Figure 9). 4. Slide cabinet side forward and out. 5. Replace cabinet sides by using the reverse of the method used to remove them. 6. Replace the ash pan cover. A sh dr aw e r A sh dr aw e
ページ9に含まれる内容の要旨
Installation All local regulations, including those referring to national and European Standards need to be complied with when installing this appliance. DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE: 1. Check clearances to combustibles to the unit and for the venting as per the pellet vent manufacturer’s installation instructions. 2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install
ページ10に含まれる内容の要旨
Installation INSTALLATION OF EXPANSION TANK: The expansion tank MUST be installed before this unit can be used. 1. Remove the expansion tank from the box located in the hopper. 2. Loosen the four (4) screws pointed out in Figure 11. Lift the back grill up and remove it from the unit. 3. Apply thread sealant to the fitting point out in Figure 12 then tighten the expansion tank onto the fitting. Figure 11 Figure 12 VENT TERMINATION REQUIREMENTS: It is recommended that your pellet stove be inst
ページ11に含まれる内容の要旨
Installation G K E B G C O p e n s D F G O p e n s B O p e n s L I A H Te r m i na ti on Ca p R e st r i ct i o n Z o ne G a s M e t e r G A i r S u p p l y I n l e t ( T e r m i na t i o n n o t a l l o w e d ) Figure 13 1. Do not terminate the vent in any enclosed or semi-enclosed areas such as a carport, garage, attic, crawlspace, narrow walkway, closely fenced area, under a sundeck or porch, or any location that can build up a concentration of fumes such as stairwells, covered breezeway, e
ページ12に含まれる内容の要旨
Installation CLEARANCES TO COMBUSTIBLES: This unit can be installed on a combustible floor C due to the built in pedestal hearth pad (for example linoleum, hardwood flooring). If combustible B flooring is underneath the unit 6 inches (153 mm) on either side and to the front must be protected by non-combustible material. If this unit is to be installed onto a carpeted surface, a hearth pad A must be used for stability. NOTE: These dimensions are minimum clearances but it is recommended t
ページ13に含まれる内容の要旨
Installation WATER LINE SCHEMATIC: The heating system for this unit must be engineered to accommodate the output of the unit. All pipes must be installed by a licensed plumber. Figure 16 13 H o t C o l d S u p p l y S h u t - O f f V al v e P r e s s u r e R elief V al ve R adi a t o r R adi at o r H o t W a t er H eat e r Ta nk P u m p S u p p ly V a l v e C h e c k V a lv e P r e s s ur e R e gu la t or E x p a n s io n T a n k E F T h e r m o 2 8
ページ14に含まれる内容の要旨
Installation HORIZONTAL THROUGH WALL INSTALLATION: The ENVIRO EF THERMO can be vented by a couple of different methods. 1. NOTE: Use only listed type “PL” or “L” pellet venting products. Failure to use listed components may cause damage or personal injury or death. 2. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house framing, plumbing, wiring, etc. 3. Install a non-combustible hearth pad un
ページ15に含まれる内容の要旨
Installation THROUGH WALL INSTALLATION: F r e s h - A i r I n t a k e 1 ” ( 2 5 m m ) W a l l t h i m b l e m a n u f a c t u r e d b y p e l l e t v e n t m a n u f a c t u r e r . 1 ” ( 2 5 m m ) 6 ” ( 1 5 0 m m ) F l o o r P r o t e c t i o n Figure 17 W a l l 1 ” T h i m b l e ( 2 . 5 c m ) 4 5 ° E l b o w 6 ” 1 2 ” ( 1 5 . 2 c m ) ( 3 0 . 5 c m ) F r e s h - A i r I n t a k e N o n - c o m b u s t i b l e F l o o r P r o t e c t i o n E x i s t i n g F l o o r R o d e n t ( c o m b u s t i
ページ16に含まれる内容の要旨
Installation INSIDE VERTICAL INSTALLATION: 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. 2. Place a non-combustible hearth pad where necessary. 3. Place the unit on the hearth pad and space it in a manner so when the pellet vent is installed vertically, it will be 3” (76 mm) away from a combustible wall. 4. Locate the center of the fresh air intake pipe on the unit. Match that center with the same point on 5 the wall and cut a hole
ページ17に含まれる内容の要旨
Installation OUTSIDE VERTICAL INSTALLATION: To accomplish an outside vertical installation, follow steps 1 through 9 in the Inside Vertical Installation section and then finish it by performing the following: 10. Install a tee with clean out on the outside of the house. 11. Install PL vent upward from the tee. Make sure that you install support brackets to keep the vent straight and secure. 12. Secure the flashing as you go through the roof. 13. Ensure that the rain cap is approximately 36”
ページ18に含まれる内容の要旨
Installation THERMOSTAT INSTALLED: This control board can be placed into two different A) HI / LOW: When the modes: When the jumper J9 is not jumped jumper is placed on only one of the J9 pins, then the control board is in a HI / LOW mode then the control board operation. If the control board is placed with J9 is in a HI / LOW mode jumped then the control board is in a ON / OFF of thermostat operation (factory setting). mode of operation. In the ON /OFF thermostat mode, the unit
ページ19に含まれる内容の要旨
Troubleshooting DO NOT: • Hold the ON / OFF BUTTON; this is a momentary contact switch and can be damaged if held down too long. • Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. • Do not remove any screws in the firebox without first lubricating them with penetrating oil. WHAT TO DO IF: 1. The stove will not start. 2. The stove will n
ページ20に含まれる内容の要旨
Troubleshooting 3. The exhaust motor will not function normally. üOpen the left side access panel; check all connections against the wiring diagram. üContact your local dealer for service. 4. The convection blower will not function normally. «Clean all grill openings at the back and below unit. «Press the fan button. Does the fan come on? Press again to verify that the blower turns on; if not, contact your local dealer for service. 5. Ignitor- the pellets will not light. Everything else in the