INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
The Keystone "B" Vent Zero Clearance Gas
B-VENT
Fireplace
GAS FIREPLACE
MODEL SERIES
MILLIVOLT
BVD34FP30(F,L)N-1
BVD36FP32(F,L)N-1
BVP42FP32(F,L)N-1
DIRECT IGNITION
BVD34FP50(F,L)N-1
BVD36FP52(F,L)N-1
GAS-FIRED
BVP42FP52(F,L)N-1
EFFECTIVE DATE
APRIL 2006
UL FILE NO. MH45034
Installer: Leave these instructions with the consumer.
Consumer: Retain these instructions for future use.
WARNING: If the information in this manual is not
followed exactly, a
ページ2に含まれる内容の要旨
TABLE OF CONTENTS Section Important Safety Information ....................................................................................................3 Safety Information for Users of LP Gas ....................................................................................4 Introduction ..............................................................................................................................5 Specifications ........................................................
ページ3に含まれる内容の要旨
IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. • If this appliance is installed directly on carpeting, • Clothing or other flammable material should not be tile or other combustible material other than wood placed on or near the appliance. flooring the appliance shall be installed on a metal or • Adequate accessibility clearances for servicing and wood panel extending the full width and depth of the proper operation
ページ4に含まれる内容の要旨
SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires them point by point with the members of your household. and explosions. In its natural state, propane is odorless Someday when there may not be a minute to lose, everyone’s and colorless. You may not know all the following safety safety will depend on knowing exactly what to do. If, after precautions which can protect both you and your family reading the following information, you feel you still ne
ページ5に含まれる内容の要旨
INTRODUCTION Instructions to Installer Any alteration of the original design, installed other than 1. Installer must leave instruction manual with owner after as shown in these instructions or use with a type of gas not installation. shown on the rating plate is the responsibility of the person 2. Installer must have owner fill out and mail warranty card and company making the change. supplied with the fireplace. Important 3. Installer should show owner how to start and operate the All correspo
ページ6に含まれる内容の要旨
SPECIFICATIONS BVD34FP BVD36FP BVP42FP Input Btu/hr Maximum 21,000 25,000 30,000 NOTE: Air shutter KWH (Maximum) 6.2 7.3 8.8 settings are factory B-Vent Size 4" Diameter 6" Diameter 6" Diameter minimum settings. Some NAT. (Standard) venting configurations #44 (.086) #42 (.0935) #37 (.104) Orifice may require minor air P-252 P-286 P-213 shutter adjustments for Air Shutter Opening 1/8" (3.2mm) 1/8"(3.2mm) 1/8" (3.2mm) optimum performance. *LP (Conversion Kit Required) 1.35mm 1.45 mm 1.65mm Or
ページ7に含まれる内容の要旨
CLEARANCES Mantel Chart (Figure 3) Clearance to Combustibles 12” (305mm) Back 0" (0 mm) 10” (254mm) Side 0" (0 mm) Floor 0" (0 mm) MANTEL Top Stand-off 0" (0 mm) COMBUSTIBLE TRIM AND MANTELS Top Framing Edge 1" (25mm) 8” ALLOWED IN SHADED AREA 6” 12 ” 4 ½ ” SEE MANTLE CHART FOR 3 3 /4 ” MAXIMUM MANTLE DEPTH 10 3 / 4 ” 3” 2 1 /4 ” 2" x 4 " HEADER 8” 1 ½ ” 6” 3/4” 5” 4” 3” ST AND OFF 2” 1” 3" (76 mm) HEIGHT T O P EDGE OF FIREPLACE SEE MANTLE CHAR T ABOVE T OP O F 1/4” FOR MINIMUM HEIGHT FIREPLACE
ページ8に含まれる内容の要旨
GAS SUPPLY The gas pipeline can be brought in through the right or left side of Installing a New Main Gas Cock the appliance. Consult the current National Fuel Gas Code, ANSI Each appliance should have its own manual gas cock. Z223.1 CAN/CGA-B149 (.1 or .2) installation code. A manual main gas cock should be located in the vicinity of Recommended Gas Pipe Diameter the unit. Where none exists, or where its size or location is not adequate, contact your local authorized installer for installa
ページ9に含まれる内容の要旨
GAS SUPPLY (CONT) Checking Manifold Pressures Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 14.0" w.c. (3.484kPa). Propane gas models will have a manifold GAS LINE HOLE pressure approximately 10.0" w.c. (2.49kPa) at t
ページ10に含まれる内容の要旨
INSTALLATION Install the Fresh Air Kit - BVA1 Framing and Finishing A fresh air kit is available as an optional feature with this appliance. 1. Choose unit location. The fresh air kit helps to decrease the amount of room air taken by 2. Frame in fireplace with a header across the top. It is important utilizing outside air for combustion. It is strongly recommended to allow for the finished face thickness when setting the depth that it be installed. Installation of the fresh air kit should
ページ11に含まれる内容の要旨
INSTALLATION (CONT) Combustible Surround Installation MANTELSHELF COMBUSTIBLE SURROUND FINISHED W ALL 2 X 4 HEADER FRONT TRIM OR NON-COMBUSTIBLE MA TERIAL MA Y OVERLAP BLACK P AINTED ST AND OFF F ACE (INST ALLA TION IS OPTIONAL) JOINT BETWEEN FINISHED W ALL AND UNIT SEALED WITH 300° F 149 ° C SEALANT MA TERIAL (SEALANT IS OPTIONAL) Minimum Framing Dimensions BVD34 BVD36 BVP42 "A" 35 3/4" 37 3/4" 37 3/4" (908mm) (959mm) (959mm) "B" 37 3/8" 39 3/8" 43 3/8" (949mm) (1,000mm) (1,102mm) "C" 14 3/8" 1
ページ12に含まれる内容の要旨
VENTING Vent Runs Note that for steep roof pitches, the vent height must be increased. In planning the installation for the fireplace, it is necessary to install In high wind conditions, nearby trees, adjoining roof lines, steep certain components before the appliance is completely positioned pitched roofs, and other similar factors can result in poor draft, and installed. These include the vent system, gas piping for the or down-drafting. In these cases, increasing the vent height may applia
ページ13に含まれる内容の要旨
VENTING (CONT) Vent Size Offset Venting - With Elbows Model BVD34FP series uses a 4" B-Vent for operation. M a x i m u m h o r i z o n t a l d i s t a n c e i s 5 0 % o f Models BVD36FP and BVP42FP series use a 6" B-Vent for v e r t i c a l v e n t h e i g h t operation. Never downsize venting diameters. Clearances Vent clearances are per vent manufacturer's specifications Vent Configuration 5 f t . M a x . Various venting configurations are shown in Figures 14 and 15 Horizontal at from which max
ページ14に含まれる内容の要旨
LOG PLACEMENT (5 LOG SET) 4 Before you begin: if you are installing logs into the BVD34 or 5 BVD36 model, then this fireplace is supplied with a set of five ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fibers. The positioning of the logs is critical to the safe and clean opera- tion of this fireplace. Sooting and other pr
ページ15に含まれる内容の要旨
LOG PLACEMENT (3 LOG SET) Before you begin: If you are installing logs into the BVP42 model then this fireplace is supplied with a set of three ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fiber. The positioning of logs is critical to safe and clean operation of this fireplace. Sooting and other problems may result if th
ページ16に含まれる内容の要旨
V E N T OPERATING INSTRUCTIONS 750 Millivolt System The OWNER should carefully read and follow these operating The standing pilot (750 millivolt system) is a continuous burning instructions at all times. Lower the door assembly to view the gas pilot. The pilot remains ON even when the main burner is OFF. controls for the fireplace. When you ignite the pilot, the thermopile produces millivolts Initial Lighting (electrical current) which energizes the magnet in the gas valve. Upon completing
ページ17に含まれる内容の要旨
OPERATING INSTRUCTIONS (CONT) Electric (120 volt) Operated Remote Control, FREC STANDING PILOT OPERATING INSTRUCTIONS The fireplace is equipped with a 15 foot length of wire that can CAUTION: Disconnect all electrical supply to the fireplace be used to connect the valve to a wall switch (installer provided) prior to installing the remote control optional equipment. or remote control receiver. See instructions packed with each of the following optional switches Installation of the 120 Volt Re
ページ18に含まれる内容の要旨
V E N T STANDING PILOT WIRING DIAGRAM (OPTIONAL) REMOTE CONTROL RECEIVER (F ACUL T A TIVE) CONTROLE E DIST ANCE DU RECEPTEUR W ALL SWITCH INTERRUPTEUR MURAL LIMIT SWITCH THERMOPILE GAS V AL V E (OPTIONAL) THERMOST A T PILOT (F ACULA TIVE) THERMOST A T VEILLEUSE W ALL SWITCH/REMOTE CONTROL RECEIVER/ THERMOST A T H N CONTROLE E DIST ANCE DU RECEPTEUR GAS V AL V E V AL VE D E GAZ Figure 23 Page 18 19400-3-0406 IN P I L O T
ページ19に含まれる内容の要旨
V E N T STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE A. This appliance has a pilot which must be lighted by hand. • Follow the gas supplier's instructions. When lighting the pilot, follow these instructions exactly. • If you can not reach your gas supplier, call the fire department. B. BEFORE LIGHTING smell all arou
ページ20に含まれる内容の要旨
STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Gas Fireplace will provide years of trouble-free service. If you do experi- ence a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken. 1. Spark ignitor will not light pilot after repeated triggering 4. Frequent pilot outage problem. of piezo ignitor button. a. Pilot flame may be too high or too low,