Studio 22
Balanced Flue
Instructions for Use,
Installation and Servicing
For use in GB, IE (Great Britain and Eire)
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the
translated instructions and in some cases the appliance will require modification. Contact Gazco for further information.
IMPORTANT
Do not attempt to burn rubbish in this appliance. This appliance must only be operated with th
ページ2に含まれる内容の要旨
COVERING THE FOLLOWING MODEL: STUDIO 22 BALANCED FLUE: 8704BFLEC P8704BFLEC PAGE APPLIANCE COMMISSIONING CHECkLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 9 Technical Specifications 9 Site Requirements 12 Installation 16 Commissioning 28 SERVICING INSTRUCTIONS 29 Fault Finding 29 How to replace parts 31 Basic spare parts list 37 Service Records 38 2
ページ3に含まれる内容の要旨
APPLIANCE COMMISSIONING CHECkLIST IMPORTANT NOTICE Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping, as the information will be required when making any guaranteed claims. FLUE CHECk PASS FAIL 1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECk 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be op
ページ4に含まれる内容の要旨
USER INSTRUCTIONS Turning the Studio On 1. GENERAL Your remote can control the gas fire from pilot ignition through to shut down. 1.1 A competent person must carry out installation and To turn the fire on: servicing. • Press the OFF button and the UP button simultaneously. 1.2 In all correspondence, please quote the appliance type and You hear several short signals. serial number, which can be found on the data badge The pilot and main burner ignite and the remote is now l
ページ5に含まれる内容の要旨
USER INSTRUCTIONS • Press and hold the DOWN arrow to decrease to If you have already set P1 and want to alter the setting for minimum P2 only: At the lowest point the fire goes to 'standby mode' (only • Press the SET button until TIMER mode is displayed pilot lit) • Hold the SET button until the display flashes the Note: While pressing a button, a symbol indicating current time for P1 transmission appears on the display. The receiver • Press the SET
ページ6に含まれる内容の要旨
USER INSTRUCTIONS 5 EMERGENCy SHUT OFF If the batteries fail during use of the fire, move the switch to the OFF (O) position, Diagram 3 (This switch is set to be ON during normal operation and must remain ON) 3 AR2119 AR2119 • Open the door outwards When closing the door ensure the door catches are fully AR1933 engaged. 4. CHANGING THE STUDIO BATTERIES 3. CLEANING THE STUDIO The appliance batteries are located behind the wall switch 3.1 Make sure the fire and s
ページ7に含まれる内容の要旨
USER INSTRUCTIONS 7 9 A AR1932 AR2121 5.3 Place Log B on the ledge at the rear of the fire, Diagram 10. 5. ARRANGEMENT OF FUEL BED 10 ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS B The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application. Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating
ページ8に含まれる内容の要旨
USER INSTRUCTIONS 12 6. FLAME FAILURE DEVICE 6.1 This is a safety feature incorporated on this appliance which automatically switches off the gas supply if the pilot goes out and fails to heat the thermocouple. D 7. RUNNING IN A 7.1 The surface coating on the metal used in your GAZCO fire AR2124 will "burn off" during the first few hours of use producing a harmless and temporary odour. This will disappear after a short period of use. If the odour persists, ask your installer for
ページ9に含まれる内容の要旨
INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: STUDIO 22 BF: 8704BFLEC P8704BFLEC Model Gas Gas Type Working Nox Aeration Injector Gas Rate Input kW (Gross) Country 3 CAT. Pressure Class m /h High Low I 8704BFLEC 2H Natural Gas (G20) 20 mbar 4 5 x 16 mm 530 0.715 7.5 3.75 GB, IE 16 x 24 (1) I P8704BFLEC Propane (G31) 37 mbar 200 0.254 7 3.6 GB, IE 3P 6 x 15 (1) REAR EXIT WALL THICkNESS Min 200 mm - Max 550 mm Efficiency Class II Flue Outlet Size Ø 150mm Flu
ページ10に含まれる内容の要旨
INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated instructions and in some cases the appliance will require modification. Contact Gazco for further information. PACkING CHECkLIST Qty Description Fixing kit containing:- 1 Log Set 1 x Instruction Manual 4 x Wood Screws 4 x Rawl Plugs 1 x Handset 4 x AA cell batteries 1 x 9V
ページ11に含まれる内容の要旨
INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION 2 Steel Frame Dimensions Steel E D Dimension: Size (mm) A 1350 F B 675 C 846 D 320 A C E 177 F 237 G 25 B G Profil Frame Dimensions E Profil Dimension: Size (mm) F D A 1036 B 510 C 940 D 414 A C E 48 F 48 G 12.5 B Bauhaus Frame Dimensions E Dimension: Size (mm) Bauhaus D F A 1050 B 524 C 940 D 414 C A E 55 F 55 G 28 B AR1550 G 11
ページ12に含まれる内容の要旨
INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1.5 Three types of flue termination are possible, rear, top exit 1. FLUE AND CHIMNEy REQUIREMENTS horizontal and top exit vertical. To measure for a top exit horizontal terminal: • Decide on the terminal position Note: This appliance must only be installed with the flue • Measure the height from the top of the appliance to the supplied. centre of the required outlet. You must adhere to the following: For minimum and maximum
ページ13に含まれる内容の要旨
INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 2.2 TOP FLUE UP & OUT WITH ADDITIONAL 2. FLUE OPTIONS BEND REAR EXIT (8708) 3 • Cut to length as required on site 1 200 mm min 500 mm max AR0630 Guard Supplied. TOP EXITS 2.1 TOP FLUE UP & OUT kIT (8534) This flue is vertical from the top of the appliance then horizontally out. (See Diagram 2). The basic kit comprises: 1 x 200mm vertical length 1 x 500mm terminal length (cut to length on site) 1 x 90° elbow When A = 1.0 to 1.499 me
ページ14に含まれる内容の要旨
INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 2.3 TOP FLUE VERTICAL kIT (8524/8524AN) NOMINAL ACTUAL STAINLESS ANTHRACITE LENGTH LENGTH FINISH FINISH Vertical from the top of the appliance (See Diagram 4). 200mm 140mm 8527 8527AN 500mm 440mm 8528 8528AN 4 1000mm 940mm 8529 8529AN 40° Bend N/A 8507 8507AN 90° Bend N/A 8508 8508AN NOTE: Carefully consider: a) Terminal positions b) Flue supports c) Weatherproofing d) Fire precautions For all the above options, you must conform to
ページ15に含まれる内容の要旨
INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 5. APPLIANCE LOCATION 5.1 Please note this appliance has been specifically designed for studwork applications although installation into other constructions, including masonry, is entirely feasible. There are two methods of installation, see Installation Instructions 3.2 Frame, 3.3 Edge 5.2 This appliance must stand on a non-combustible hearth/ platform that is at least 12mm thick. NOTE: It is recommended you construct the back panel of t
ページ16に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INSTALLATION IMPORTANT: REFER TO DATA BADGE AND TECHNICAL 1 SPECIFICATION AT THE FRONT OF THE MANUAL TO ENSURE THE APPLIANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE. FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 10, SERVICING, ‘REPLACING PARTS’. 1. SAFETy PRECAUTIONS AR2119 AR2119 1.1 For your own and other’s safety, you must install this fire
ページ17に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INSTALLATION 2.5 You can now remove the burner: With all screws removed: • Slide the control unit to the left to clear the injector and pilot pipework at the right side • Undo the four screws holding the burner tray in place • Lift the right-hand side up and out • Remove the burner • Lift the left-hand side up and out 7 4 AR2128 AR2117 2.6 • Undo the two screws in the rear air baffle to remove it, Di
ページ18に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INSTALLATION 3.4 AN ACCESS HATCH MUST BE LEFT IN THE SIDE OF THE 3. STUD WORk INSTALLATION CHIMNEy BREAST FOR FUTURE SERVICING AND INSPECTION OF THE FLUE AND APPLIANCE. THERE ARE THREE TyPES OF INSTALLATION INTO STUDWORk DESCRIBED IN THE FOLLOWING PAGES: 4. STUDWORk INSTALLATION FOR STUDIO WITH FRAMES 1) FOR STUDIO 22 WITH EITHER THE STEEL, PROFIL OR BAUHAUS FRAME, SEE SECTION 4 • Build the studwork chimney breast and enclosures to 2) FOR A
ページ19に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INSTALLATION • Fit the support bar into the studwork at the correct • Secure the fire back to the studwork using four screws height, Diagram 11. through flange, bracket, support bar • Apply a plaster finish to the front of the chimney breast 11 Slips Because of the high temperatures this fire achieves, it is advisable to use marble slips or similar material between the appliance and the plasterboard. Never use a one-piece sli
ページ20に含まれる内容の要旨
INSTALLATION INSTRUCTIONS INSTALLATION 15 Build the studwork chimney breast to the desired size: • Ensure all clearances to combustible material are maintained, Section 3, 3.1 above • Decide on flue requirements • Cut a hole for the flue exit - see Installation Instructions, Flue Assembly 18 AR2134 • Put vertical studwork at minimum clearance to the side of the fire (50mm) • Secure to the vertical studwork through the holes in the