Owners &
™
Regency Bellavista B36X
Installation Manual
MODEL: B36X
Gas Fireplace
Medium DV Gas Fireplace
www.regency-fi re.com
FOR YOUR SAFETY
WARNING:
What to do if you smell gas:
If the information in these instructions are not followed exactly,
Do not try to light any appliance
a fi re or explosion may result causing property damage,
Do not touch any electrical switch:
personal injury or loss of life.
do not use any phone in your
FOR YOUR SAFETY
building.
Do not store or use gasol
ページ2に含まれる内容の要旨
To the New Owner: Congratulations! ® You are the owner of a state-of-the-art Gas Fireplace by REGENCY . The Bellavista™ B36X has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The Bellavista™ B36X has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment ® now to acqua
ページ3に含まれる内容の要旨
TABLE OF CONTENTS SAFETY LABEL Pilot Adjustment ...........................................................35 High Elevation .............................................................35 Gas Pipe Pressure Testing ..........................................35 Copy of Safety Decal .....................................................4 S.I.T. Valve Description ................................................35 Aeration Adjustment ....................................................36 REQUIREMENTS
ページ4に含まれる内容の要旨
SAFETY LABEL This is a copy of the label that accompanies each Bellavista™ B36X Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. ® NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one. For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts. For the State of Massachuse
ページ5に含まれる内容の要旨
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished gra
ページ6に含まれる内容の要旨
DIMENSIONS UNIT DIMENSIONS 33” (838mm) 35-1/4” (895mm) 30-3/8” (762mm) 39-1/16” (992mm) 21”(533mm) 37-1/2” (953mm) 1”(25.4mm) 36” (914mm) 33-1/16” (840mm) 35-1/4” (895mm) 26-1/2” (673mm) 17-5/16” (440mm) 19-5/16” (490mm) 20-1/4” (514mm) 6 Regency Bellavista™ B36X Gas Fireplace
ページ7に含まれる内容の要旨
INSTALLATION 11) Under no circumstances should this appliance IMPORTANT MESSAGE YOUNG CHILDREN SHOULD BE be modifi ed. Parts that have to be removed CAREFULLY SUPERVISED WHEN for servicing should be replaced prior to SAVE THESE THEY ARE IN THE SAME ROOM AS operating this appliance. INSTRUCTIONS THE APPLIANCE. 12) Installation and any repairs to this appliance The Bellavista™ B36X Gas Fireplace must be should be done by a qualifi ed service person. CLOTHING OR OTHER FLAMMABLE installed
ページ8に含まれる内容の要旨
INSTALLATION This includes: 4) This appliance is Listed for bedroom INSTALLATION installations using the standard Remote 1) Clocking the appliance to ensure the correct (millivolt thermostat system). Some areas CHECKLIST fi ring rate (rate noted on label) after burning may have further requirements, check local appliance for 15 minutes. codes before installation. 1) Locate appliance a) Room location (Refer to "Locating Your 2) If required, adjusting the primary air to ensure 5) The
ページ9に含まれる内容の要旨
INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fi replace and vent system be installed only in accordance with these instructions. Caution Requirements WARNING The top, back and sides of the fi replace are defi ned by Fire hazard is an extreme risk standoffs. The metal ends of the sta
ページ10に含まれる内容の要旨
INSTALLATION MANTEL CLEARANCES Due to the extreme heat this fi replace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. Note: A non-combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non- combustible board. Mantel Clearances 14 12 10 8 6 4 2 Note: Ensure the paint that is used on the mantel and the facing is "heat resistant" or the paint may discolour.
ページ11に含まれる内容の要旨
INSTALLATION FRAMING Framing Dimensions Description B36X M Framing Width 36 - 1/4"(921mm) N Framing Height 39 - 3/8" (1000mm) O (Rear Vent) Framing Depth - Rear Vent 20 - 3/4" (527mm) O (Top Vent) Framing Depth - Top Vent 19 - 1/2" (495mm) P (Top Vent) Corner Facing Wall Depth 48 - 5/8" (1235mm) P (Rear Vent) Corner Facing Wall Depth 53" (1346mm) AstroCapXL 61-1/2" (1562mm) - other approved caps Q (Top Vent) Corner Facing Wall Width 68 - 3/4" (1746mm) Q (Rear Vent) Corner Facing Wall Wid
ページ12に含まれる内容の要旨
INSTALLATION FINISHING IMPORTANT FINISHING DETAIL NOTE: Important: Finishing materials such as tile, river rock, etc, must not protrude Before placing unit into fi nal position - it is important to know the total beyond the front facing fl anges the sides and top of the fi rebox thickness / height of fi nished hearth (tile, carpet, etc.) The base of the opening. fi replace should be level or higher than the fi nished hearth height. Full Screen Doors Only: If
ページ13に含まれる内容の要旨
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION BEFORE YOU START The Top Facing Support, the Side Nailing Strips, the 2 Top Standoffs and the Flue Collar must be correctly positioned and attached before the fi replace is moved into position. TOP STANDOFF ASSEMBLY The top standoffs are shipped in a fl at position and must be folded into shape and attached. 1) Remove the standoffs from the fi replace top. 2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the
ページ14に含まれる内容の要旨
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION TOP FLUE COLLAR INSTALLATION Note: This conversion must be done prior to the unit being placed in position. The unit comes equipped as a rear vent unit. These instructions are to be used, only if the unit is going to be top vented. Top Collar Assembly Kit 1 Intake Collar Assembly with Gasket 1 Intake Collar Plate with Gasket 1 Top/Rear Exhaust Assembly with Gasket 1 Heat Defl ector 1 Baffl e Plate 29 1/4" x 1/2" Screws (4 spares) Intake Collar Pla
ページ15に含まれる内容の要旨
INSTALLATION 5) From the outside rear of the fi rebox, remove the intake collar 8) From the outside top of the fi rebox, install the intake collar assembly. assembly. Remove the 4 - 1/4" x 1/2" screws. See Diagram 5. Secure with 4 - 1/4" x 1/2" screws. Ensure all screws are tight, but do not over tighten. All 4 screws must be used. Exhaust Assembly Exhaust Assembly Intake Collar Assembly Diagram 9 Diagram 5 Intake Collar Assembly 6) From the outside top of the fi rebox, remove the intake
ページ16に含まれる内容の要旨
INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS 1 2 Canada USA Minimum Clearance Requirements A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) B Clearance to window or door that may be opened 12"(30cm) 9" (23cm) C Clearance to permanently closed window ** D Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of 2 feet (61cm) 24"(60cm) 24"(60cm) E Clearance to unventilated soffi t 12"(30cm) 12"(30cm) F Clearance to outsid
ページ17に含まれる内容の要旨
INSTALLATION APPROVED VENTING CONFIGURATIONS HORIZONTAL & VERTICAL TERMINATIONS Regency Bellavista™ B36X Gas Fireplace 17
ページ18に含まれる内容の要旨
INSTALLATION APPROVED VENTING CONFIGURATIONS HORIZONTAL & VERTICAL TERMINATIONS Vertical Venting Configurations Vertical Rear Vent Flex Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved Vertical Rear Vent Flex Vent 5" x 8" Not Approved Not Approved This application is NOT approved Not Approved Vertical Rear Vent Rigid Vent 4" x 6-5/8" Not Approved Not Approved This application is NOT approved Not Approved Vertical Rear Vent Rigid Vent 5" x 8" Not Approved N
ページ19に含まれる内容の要旨
INSTALLATION RIGID PIPE CROSS REFERENCE CHART 4" X 6-5/8" (MUST USE VENT REDUCER # 946-606 AND RIGID PIPE ADAPTOR #770-994) Components from different Manufacturers may not be mixed. Not all Rigid Pipe components are available directly from FPI. Regency Bellavista™ B36X Gas Fireplace 19
ページ20に含まれる内容の要旨
INSTALLATION 20 Regency Bellavista™ B36X Gas Fireplace