Owners &
Freestanding Woodstoves
Installation Manual
Medium Freestanding Woodstove
with optional Gold Legs.
Medium Freestanding Step Stove
with Pedestal Base.
MODELS: F1100S F2100M F3100L S2100M S3100L
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
908-288 FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 01/13/03
ページ2に含まれる内容の要旨
Thank-you for purchasing a REGENCY FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning. SAFETY NOTE: If this woodstove is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building or fir
ページ3に含まれる内容の要旨
TABLE OF CONTENTS THE REGENCY FREESTANDING STOVE SAFETY LABEL Door Handle ...................................................................... 17 Glass Installation .............................................................. 17 Small Freestanding Stove F1100S ..................................... 4 Optional Accessories Medium Freestanding Stove F2100M ................................. 5 - Pedestal Ash Drawer Kit .......................................... 17 Large Freestanding Stove F3100L .
ページ4に含まれる内容の要旨
SIDE SIDEWALL SAFETY LABEL This is a copy of the label that accompanies of the back of the stove. We have printed a copy NOTE: Regency units are constantly being each Regency Small Freestanding Woodstove of the contents here for your review. improved. Check the label on the unit and if there (F1100S). It is located in the upper right corner is a difference, the label on the unit is the correct one. 100 DO NOT REMOVE THIS LABEL LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO SUITABLE FOR MOBILE HOME
ページ5に含まれる内容の要旨
SIDE SIDEWALL SAFETY LABEL This is a copy of the label that accompanies corner of the back of the stove. We have printed NOTE: Regency units are constantly being each Regency Medium Freestanding Wood- a copy of the contents here for your review. improved. Check the label on the unit and if there stove (F2100M). It is located in the upper right is a difference, the label on the unit is the correct one. DO NOT REMOVE THIS LABEL LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO SUITABLE FOR MOBILE HOME I
ページ6に含まれる内容の要旨
SIDE SIDEWALL SAFETY LABEL This is a copy of the label that accompanies of the back of the stove. We have printed a NOTE: Regency units are constantly being each Regency Large Freestanding Woodstove copy of the contents here for your review. improved. Check the label on the unit and if there (F3100L). It is located in the upper right corner is a difference, the label on the unit is the correct one. DO NOT REMOVE THIS LABEL LISTED SPACE HEATER, SOLID FUEL TYPE, SUITABLE FOR MOBILE HOME INSTALLAT
ページ7に含まれる内容の要旨
SIDE SIDEWALL SAFETY LABEL This is a copy of the label that accompanies each of the back of the stove. We have printed a copy NOTE: Regency units are constantly being Regency Medium Freestanding Step Woodstove of the contents here for your review. improved. Check the label on the unit and if (S2100M). It is located in the upper right corner there is a difference, the label on the unit is the correct one. 107 DO NOT REMOVE THIS LABEL LISTED SPACE HEATER, SOLID FUEL TYPE, ALSO SUITABLE FOR MOBILE
ページ8に含まれる内容の要旨
SAFETY LABEL This is a copy of the label that accompanies corner of the back of the stove. We have printed NOTE: Regency units are constantly being each Regency Large Freestanding Step Wood- a copy of the contents here for your review. improved. Check the label on the unit and if there stove (S3100L). It is located in the upper right is a difference, the label on the unit is the correct one. Regency Freestanding Woodstove 8
ページ9に含まれる内容の要旨
INSTALLATION chimney must be listed as suitable for use your local building authority. RESIDENTIAL with solid fuels. For other types of chim- neys check with your local building code 12) A chimney connector cannot pass through INSTALLATION officials. Do not confuse a chimney with a an attic or roof space, closet or similar 1) Read all instructions before installing your type “B” Venting System used for gas concealed space, or a floor, ceiling, wall or Regency Stove. Install and use only in appli
ページ10に含まれる内容の要旨
INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS Please read the section below carefully as clearances depend on whether the airmate or the rear heat deflector is installed on the stove. Measurements "From Unit" are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall. Residential Installation “C” Vent (Single Wall) Unit From Unit From Corner From Flue Center-line ABCDE F Small F1100S with Airmate 13" 11" 8
ページ11に含まれる内容の要旨
INSTALLATION Minimum Alcove Clearance to Combustible Materials The Regency Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level. Note: Minimum alcove ceiling height - 84" Maximum depth of alcove - 36" From From Flue Min. Min.Hearth Unit Unit Center-line Width to Rear Wall GH I J K L Small F1100S with Airmate 11" 7" 23" 13.5" 46" 39" with Rear Deflector 13" 5" 25" 11.5" 50" 37" M
ページ12に含まれる内容の要旨
INSTALLATION Rear Heat Deflector Assembly for Pedestal Assembly STOVE ASSEMBLY F1100, F2100, and F3100 PRIOR TO Small 850-115 Medium 850-215 Small & Medium 815-555 INSTALLATION Large 850-315 Large 815-556 All units require either the pedestal or 4 legs 1) For easier assembly, tip the stove on its The rear heat deflector is supplied with the attached to the base. The F1100, F2100, and back (onto a soft surface to prevent scratch- stove and must be installed unless the optional F3100 stoves requir
ページ13に含まれる内容の要旨
INSTALLATION 8) To complete your chimney installation, in- Leg and Bottom Shield Assembly STEP BY STEP stall the double wall connector pipe from the stove’s flue collar to the chimney sup- Bottom Shield CHIMNEY AND port device. Small 850-121 CONNECTOR Medium 850-221 9) If you are using a horizontal connector, the Large 850-321 INSTALLATION: chimney connector should be as high as possible while still maintaining the 18" min- Legs (set of 4) Note: These are a generic set of chim- imum distance fr
ページ14に含まれる内容の要旨
INSTALLATION TABLE 1 MINIMUM RECOMMENDED FLUE HEIGHTS IN FEET (Measured from the top of the unit) # OF ELBOWS ELEVATION (FT) o o o o o o ABOVE SEA LEVEL 0 2 x 15 4 x 15 2 x 30 4 x 30 2 x 45 4 x 45 0-1000 12.0 13.0 14.0 15.0 18.0 16.0 20.0 1000-2000 12.5 13.5 14.5 15.5 19.0 16.5 21.0 2000-3000 13.0 14.0 15.0 16.0 19.5 17.0 21.5 3000-4000 13.5 14.5 15.5 17.0 20.0 18.0 22.5 4000-5000 14.
ページ15に含まれる内容の要旨
INSTALLATION SIMPSON DURA-PLUS Large Stoves F3100L and S3100L LISTED COMPONENTS Qty.Part # Description 1 6DVL8693 Connector Kit FOR MOBILE HOME The unit arrives with the first two air tubes (from 1 6DP-MH9096 Mobile Home Kit the front) and the 2 baffle bricks on the floor of INSTALLATION the firebox. The baffle bricks are positioned ICC EXCEL 2100 first and then the air tubes are installed. Qty.Part # Description The Regency Small, Medium, Medium Step and 1 6CL48 48" Chimney length (also in 12"
ページ16に含まれる内容の要旨
INSTALLATION 4) Install the two front air tubes into the holes manner as Step 1) above. Then reposition on the side channels. The notch goes on the left baffle brick flat on the air tubes. the right hand side with the air holes facing forward toward the door opening. If the tube will not slide in easily, simply use a pair of vise grips or pliers and tap it into place with a hammer. A tighter fit will ensure the tube will not move when the unit is burning. Side View 3) Tilt the left baffle bric
ページ17に含まれる内容の要旨
INSTALLATION Pedestal Ash Drawer Kit (850-100) BRICK INSTALLATION DOOR HANDLE 1) Remove the bricks from the floor of the Firebrick is included to extend the life of your Attach spring handle by rotating counter clock- firebox. stove and radiate heat more evenly. Check to wise onto rod. Ensure that the rod fits into the entire length of the spring handle. See Diagram see that all firebricks are in their correct posi- 2) If using ashdrawer, discard cover plate. tions and have not become misalig
ページ18に含まれる内容の要旨
INSTALLATION Blower/Fan (846-515) 1) Remove the two screws from the top of the fan housing. 2) Slide the fan up into the rear heat shield. 3) After aligning holes, secure the fan to the rear heat shield using the two screws removed earlier. Note: The connection cord should not be in contact with any hot surfac- es. Read the operating instructions for the fan before using. See Page 19. Blower/Fan Wiring Diagram WARNING: Electrical Grounding Instructions CAUTION: Label all wires prior to disconn
ページ19に含まれる内容の要旨
OPERATING INSTRUCTIONS 4) After about 15 to 20 minutes, when your CAUTION: If the body of your unit, OPERATING wood has begun to burn strongly, adjust flue baffle or any part of the chim- your draft control down to keep the fire at INSTRUCTIONS ney connector starts to glow, you a moderate level. are overfiring. Stop loading fuel With your unit now correctly installed and WARNING: Never build a roaring fire in immediately and close the draft safety inspected by your local authority, you a cold
ページ20に含まれる内容の要旨
OPERATING INSTRUCTIONS Bottom Shield (with Legs) Units: clothing and furniture away. Warn chil- ASH DISPOSAL To remove the drawer, lift slightly and slide dren of the burn hazard. it out, and carry it away. During constant use, ashes should be removed 8) The stove consumes air while operating, every few days. The Ash Drawer option fea- provide adequate ventilation with an air tures a convenient ash dump for easy removal duct or open a window while the stove is of ash, see "Modular Options" on p