WARNING: If the information in this manual is not followed exactly, a
fire or explosion may result causing property damage, personal injury, or
loss of life .
-DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS
ページ2に含まれる内容の要旨
ページ3に含まれる内容の要旨
TABLE OF CONTENTS SECTION I: Safety Information ……………………………………… 1 SECTION II: Residential Installation-Unvented Gas Logs……………..4 Clearances……………………………………………………………….5 Gas Connection………………………………………………………....6 Preparing Log Kit……………………………………………………….6 Gas Pressure Check……………………………………………………..8 Lighting Instruction……………………………………………………..9 Flame Check…………………………………………………………...13 Heat Output…………………………………………………………….13 SECTION III: Installation-Heat Shield…………………………
ページ4に含まれる内容の要旨
ページ5に含まれる内容の要旨
SECTION I SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SER- VICE THE APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLO- SION, AND CARBON MONOXIDE POISONING.
ページ6に含まれる内容の要旨
5. Two models are available. One specific model for propane (LP), and one for natural gas. Use the correct gas type for your home. This unit is not field convertible. 6. If these gas logs are for use with propane gas, do not place propane supply tank(s) inside any structure. Locate propane supply tank(s) outdoors. 7. If
ページ7に含まれる内容の要旨
19. Make sure any safety screen or guard (if any) that was removed for servicing is in place before operating gas logs. 20. Strong drafts, such as a ceiling fan placed directly in front of the fireplace, may create sooting. Sooting may discolor walls. 21. Installation and repair should be done by a qualified service person. The heater and the gas logs should be inspected before use and at least annually by a professional service person. More frequent cleaning m
ページ8に含まれる内容の要旨
SECTION II RESIDENTIAL INSTALLATION OF GAS LOGS FIREPLACE PREPARATION The fireplace needs to be prepared before installing the gas logs. A. Turn off the gas supply to the fireplace. B. Any outside air ducts on the fireplace shall be permanently closed at the time of the appliance installation. “WARNING: BEFORE INSTALLING IN A SOLID FUEL BURNING FIREPLACE, THE CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES AND LOOSE PAINT
ページ9に含まれる内容の要旨
“WARNING: THIS APPLIANCE IS FOR INSTALLATION ONLY IN A SOLID FUEL BURNING MASONRY OR UL127 FACTORY BUILT FIREPLACE OR IN A LISTED VENTLESS FIREBOX ENCLOSURE. IT HAS BEEN DESIGN CERTIFIED FOR THESE INSTALLATIONS . EXCEPTION: DO NOT INSTALL THIS APPLIANCE IN A FACTORY BUILT FIREPLACE THAT IN- CLUDES INSTRUCTIONS STATING IT HAS NOT BEEN TESTED OR SHOULD NOT BE USED WITH UNVENTED GAS LOGS”. INSTALLATION AND CLEARANCES T
ページ10に含まれる内容の要旨
GAS CONNECTION Check gas type. Use only the type of gas indicated on the valve rating plate. If the type of gas listed on the plate is not your type of gas supply, DO NOT INSTALL. Contact your dealer for proper model. Always use an external regulator for all LP heaters to reduce the supply tank pressure to a maximum of 13” W.C. This is in addition to the regulator furnished with the heater. Warning: Connection directly to an unregulated LP tank can cause an explosion. The norma
ページ11に含まれる内容の要旨
CR8T LOG PLACEMENT DIAGRAM 3 1 2 Figure 2 Refer to PREPARING LOG KIT page 6. “WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury.” 7
ページ12に含まれる内容の要旨
GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is as shown in the table below. NOTE: The pressure check point is located on right side of valve facing the burner. The appliance and its main gas valve must be disconnected from the gas supply piping sys- tem during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa). The appliance must be isolated from the gas supply piping system by closing its equipment shut-off valve dur
ページ13に含まれる内容の要旨
OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following checklist . 1. Read and understand these instructions before operating this appliance. 2. Check that there no leaks. If you smell gas do not attempt to light this appliance. 3. Verify that log placement is correct. LIGHTING INSTRUCTIONS MODULATING VALVE(MAXITROL) FOR YOUR SAFETY, READ BEFORE LI
ページ14に含まれる内容の要旨
OFF MERTIK MAXITROL 7 6 1 5 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the previous page. 2. Make sure manual shutoff valve is fully closed. 3. Open access panel door, located in lower front center of base for access to control knobs. 4. Turn off all electric power to the appliance. 5. Set thermostat (flame control) to lowest setting. 6. Push in and turn control knob clockwise
ページ15に含まれる内容の要旨
IGNITER ELECTRODE O.D.S PILOT BURNER PILOT THERMO-COUPLE 13. Close the access panel door. 14. “Turn on all electric power to the appliance.” CAUTION DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE. TO TURN OFF GAS TO APPLIANCE SHUTTING OFF UNIT: 1. Open access panel door, located in lower front center of base for access to control knobs. 2. Set thermostat (flame c
ページ16に含まれる内容の要旨
THERMOSTAT CONTROL OPERATION The thermostat control used on this heater differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature and adjusts the amount of gas flow to the burner. This will increase or decrease the flame height. At times, the room may exceed the set temperature, which will cause the burner to shut off. When room temperature drops below the thermostat setting, the b
ページ17に含まれる内容の要旨
BURNER & PILOT FLAME CHECK A periodic check of the flames should be made. The flame should always be present when the gas logs are in operation. Flames: The flame should extend about 3” to 4” above the rear log for natural gas and about 6” for propane (LP) gas. CR8T LOGS & BASE PILOT NATURAL PROPANE Figure 4 WHEN USED AS A HEATING APPLIANCE HEAT OUTPUT The heat output into the room can be controlled by the position o
ページ18に含まれる内容の要旨
SECTION III INSTALLATION OF LOG SET WITH (OPTION ) HEAT SHIELD MODEL 19HS For installation of gas supply see “Fireplace and Gas Connection” Page 6, Section II. NOTE: The same clearances for the log set are also used with the 19 Heat Shield. See Page 4, Section II, Figure 1. NOTE: Centrally locate the Heat Shield in the fireplace and place it deep enough into the fireplace to accomplish adequate draft (if use as a vented heater is plann
ページ19に含まれる内容の要旨
REPLACEMENT PARTS FOR (OPTIONAL) HEAT SHIELD MODEL 19HS Always include correct name, part number, and model number when ordering service Parts. KEYS# PART DESCRIPTION PART NUMBER 1. BLOWER PEA2-40-01 RATING:120volts/60HZ/ .54Amps 2.
ページ20に含まれる内容の要旨
WARNING: CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THESE GAS LOGS. WARNING: Clothing or other flammable material should not be placed on or near this appliance. WIRING DIAGRAM (FOR OPTIONAL HEAT SHIELD MODEL 19HS ) THERMOSTAT JUMPER