ページ1に含まれる内容の要旨
1
INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS, CSA 2.22, AND ANSI Z21.50 RESPECTIVELY FOR VENTED GAS FIREPLACES.
GAS - INSERTS
INSTALLATION AND OPERATION INSTRUCTIONS FOR
GAS-FIRED VENTED FIREPLACE
NATURAL GAS MODEL GI 3600 - N
PROPANE GAS MODEL GI 3600 - P
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI / CSA METHODS
WARNING: If the information in these instructions is not followed exactly, a fire
ページ2に含まれる内容の要旨
2 TABLE of CONTENTS PG 2-5 INTRODUCTION 8 OPERATION / MAINTENANCE CONT'D Warranty Operating Instructions General Instructions Maintenance General Information 9 BLOWER SYSTEM Care of Glass, & Plated Parts Blower Replacement Instructions 5 INSTALLATION 9 ADJUSTMENTS 6-7 FINISHING Pilot Burner Adjustment Brick panels Venturi Adjustments Log Placement/Charcoal Embers 10-11 REPLACEMENTS Louvre Installation Ordering Replacement Parts Logo Placement Replacement Parts 7 OPERATION / MAINTENANCE Accessori
ページ3に含まれる内容の要旨
3 NAPOLEON gas fireplaces are manufactured under the strict Standard of the world recognized ISO 9001 : 2000 Quality Assurance Certificate. NAPOLEON products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The burner and valve assembly are leak and test-fired at a quality test station. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the cus- tomer, receives the qu
ページ4に含まれる内容の要旨
4 The fireplace, when installed, must be electrically con- GENERAL INSTRUCTIONS nected and grounded in accordance with local codes. In THIS GAS FIREPLACE SHOULD BE INSTALLED AND the absence of local codes, use the current CSA C22.1 SERVICED BY A QUALIFIED INSTALLER to conform with CANADIAN ELECTRICAL CODE in Canada or the ANSI/ local codes. Installation practices vary from region to re- NFPA 70 NATIONAL ELECTRICAL CODE in the United gion and it is important to know the specifics that apply to
ページ5に含まれる内容の要旨
5 FIGURE 1 INSTALLATION Line the chimney with a 3" or 4" diameter approved liner. Clean out ashes from the inside of the wood-burning fire- With a 4" liner, an increaser must be connected between place. Make sure that the chimney and wood-burning fire- the dilution draft hood and the liner. Chimney installation place are in a clean and sound condition and constructed must conform to both national and local code requirements. of non-combustible materials. If necessary have any repair The liner mu
ページ6に含まれる内容の要旨
6 An on/off switch has been included and can be located at The insert can be equipped with a flashing kit to close off most fireplace openings. Mount the flashing inside the unit's the right side trim. For ease of accessibility, this switch may be replaced with a wall switch or substituted with a outer shell using 4 securing screws. The flashing and trim millivolt thermostat that may be installed in a convenient are available in many finishes to accent any room decor. location on any wall. Route
ページ7に含まれる内容の要旨
7 FINISHING FIBRE FIREBRICK PANELS CHARCOAL EMBERS To give your insert that authentic masonry fireplace look, Randomly place the embers beneath the front log, cover- optional fibre firebrick panels are available at your Napo- ing all of the burner area beneath the hollowed out section leon / Wolf Steel Ltd. dealer. Complete installation and main- of the log. Place the remaining embers along the front. tenance instructions are included with the kit. Keep ember dust away from burner ports to avoi
ページ8に含まれる内容の要旨
8 LOGO PLACEMENT Remove the backing of the logo supplied and place on the glass viewing area, as indicated. 3 1 /8" LOGO 1 1 / " 8 FIGURE 9 OPERATION / MAINTENANCE SPILL SWITCH VENTING ACTION CHECK This is a thermally activated switch, attached to the back of A CHECK FOR CORRECT VENTING ACTION MUST BE the unit and extending up into the dilution draft hood, which MADE BEFORE THE INSTALLED INSERT IS LEFT WITH senses the change in temperature and shuts down the THE CUSTOMER. gas valve in the event
ページ9に含まれる内容の要旨
9 FOR YOUR SAFETY READ BEFORE LIGHTING: A This fireplace has a pilot which must be lit by hand turn by hand, do not try to repair it. Call a qualified ser- while following these instructions exactly. vice technician. Force or attempted repair may result in B Before lighting, smell all around the fireplace area for a fire or explosion. gas and next to the floor because some gas is heavier D Do not use this fireplace if any part has been under than air and will settle on the floor. water. Immediat
ページ10に含まれる内容の要旨
10 BLOWER SYSTEM The Napoleon gas fireplace insert comes standard with a BLOWER REPLACEMENT INSTRUCTIONS blower, a heat sensor, variable on/off speed control and a Turn off the gas and electric power to the unit. power cord. Because the blower is thermally activated, Remove the upper glass bracket. Loosen the lower glass when turned on, it will automatically start approximately 15 bracket and remove the glass. minutes after lighting the fireplace and will run for approxi- Remove the log
ページ11に含まれる内容の要旨
11 REPLACEMENTS Contact your dealer for questions concerning prices and When ordering replacement parts always give the follow- availability of replacement parts. Normally all parts can be ing information: ordered through your Napoleon dealer or distributor. 1. MODEL & SERIAL NUMBER OF FIREPLACE 2. INSTALLATION DATE OF FIREPLACE FOR FOR FOR FOR FOR WARRANTY WARRANTY WARRANTY WARRANTY WARRANTY REPL REPL REPL REPL REPLA AAA ACEMENT CEMENT CEMENT CEMENT CEMENT PPPPPAR AR AR AR ARTS TS
ページ12に含まれる内容の要旨
12 W415-0061 / B / 01.11.05
ページ13に含まれる内容の要旨
13 TROUBLE SHOOTING GUIDE BEFORE ATTEMPTING TO TROUBLESHOOT, PURGE YOUR UNIT AND INITIALLY LIGHT THE PILOT AND THE MAIN BURNER WITH THE GLASS DOOR REMOVED. SYMPTOM PROBLEM TEST SOLUTION - purge the gas line with the glass door removed. Pilot goes out when System is not correctly purged. the gas knob is re- - fill the tank. Out of propane gas. leased. Pilot flame is not large enough - turn up the pilot flame. - gently twist the pilot head to improve the flame pattern Pilot flame is not engulf
ページ14に含まれる内容の要旨
14 SYMPTOM PROBLEM TEST SOLUTION Main burner goes out; Refer to "Main burner goes out; pilot stays on" pilot goes out. Chimney down-drafting - wait ten minutes. Shut off all exhaust fans in the house (ie: kitchen and bathrooms), furnace, and clothes dryer. Open windows and/or doors. Start fireplace and monitor its opera- tion. Close doors and windows and start appliances as before; room is in negative pressure; increase fresh air supply. Chimney is blocked - check for chimney blockage. Liner
ページ15に含まれる内容の要旨
15 W415-0061 / B / 01.11.05 Wolf Steel Fireplace Service History This fireplace must be serviced annually depending on usage. Service Technician Date Dealer Name Service Performed Special Concerns Name
ページ16に含まれる内容の要旨
16 NOTES W415-0061 / B / 01.11.05