ページ1に含まれる内容の要旨
HEARTH PRODUCTS
KITS AND ACCESSORIES
775,239M
DESIGNER™ GaS CONvERSION INSTRuCTIONS LP TO NG
Rev. a, 08/2008
CaT. NO. H5428, MODEL DBv-CK-LP TO NG
INSTaLLaTION INSTRuCTIONS FOR CONvERTING FROM PROP aNE GaS (LP) TO
NaTuRaL GaS (NG). FOR uSE w ITH THE DESIGNER™ DIRECT vENT GaS FIREPLaCE INSERTS
KIT CONTENTS (See Figure 1):
avERTISSEMENT
1 ea. Robertshaw NG Regulator Kit (A)
1 ea. #37 NG main burner orifice (30,000 BTU’s) (B)
Cet équipement de conversion sera installé par une
1 e
ページ2に含まれる内容の要旨
REaD aLL THE STEPS BEFORE STaRTING THE CONvERSION. INSTaLLER NOTICE: THESE INSTRuCTIONS MuST BE LEFT wITH Screw THE aPPLIaNCE. This kit contains components required to convert this appliance from using Propane Gas to using Natural Gas as the only fuel. Glass Door all of these components must be replaced in order for the unit to operate safely on Natural Gas. when installing gas components use pipe joint compound or 5/32” allen Teflon tape on all pipe fittings before installing (ensure pr
ページ3に含まれる内容の要旨
Step 6. To remove burner, unscrew the 5/32” allen head screw, securing Step 9. Firmly pull the pilot hood straight up and off to access the hexed the right end of the burner. See Figure 8. pilot orifice (see Figures 11 and 13). Use a 5/32” allen head wrench to unscrew the pilot orifice and lift it out (see Figures Step 7. Next, push the air shutter control lever in until it stops. See 12 and 13). Replace with the new NG pilot orifice provided. Re- Figure 9. install the pilot hood. Note:
ページ4に含まれる内容の要旨
Step 10.Using 1/2” open end wrench, remove the LP burner orifice. Install Inlet Gas Supply Pressure the new NG orifice. Make sure to use pipe sealing compound on threads of the new orifice (see Figure 14). Fuel # Minimum Maximum Desired Nat. 5" w C/po. C.E 10.5" w C/po. C.E 7" wC/po. C.E Gas (1.24 kPa) (2.61 kPa) (1.74 kPa) Manifold Gas Supply Pressure Fuel # Low High 1/2” End wrench Natural (Lo) 1.7" w C/po. C.E (Hi) 3.5" w C/po. C.E Gas (0.42 kPa) (0.87 kPa) Step 14. Reinstall the burner,