INSTALLATION INSTRUCTIONS
MANUAL
DIRECT-VENT GAS FIREPLACE HEATER INSERTS
Elite™ Series, Models: EDVI25, EDVI30 & EDVI35
Suitable for installation into masonry or factory built fi replaces.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 775,156M Rev. G, 3/2005
Report No. 116-F-14-5
These appliances may be installed in an aftermarket permanently located,
manufactured (mobile) home, where not prohibited by local codes.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
WARNING: IF THE INFORMATIO
ページ2に含まれる内容の要旨
These appliances comply with National CONGRATULATIONS ON THE PURCHASE OF YOUR NEW GAS APPLIANCE MANU- Safety Standards and are tested and listed FACTURED BY LENNOX HEARTH PRODUCTS. by OMNI-Test Laboratories Inc.; Beaverton, Oregon (Report No. 116-F-14-5) to ANSI When you purchased your new gas fi red heater, you joined the ranks of thousands of Z21.88 (in Canada, CSA-2.33), and CAN/ concerned individuals whose answer to their home heating needs refl ects their concern for CGA-2.17-M91 in bo
ページ3に含まれる内容の要旨
The millivolt appliances are manually con- CARBON MONOXIDE POISONING: EARLY Manifold Gas Supply Pressure (all models) trolled and feature a spark igniter (piezo) SIGNS OF CARBON MONOXIDE POISONING Fuel Low High that allows the appliance's pilot gas to be ARE SIMILAR TO THE FLU WITH HEAD- (LO) 1.6” WC (HI) 3.5” WC lit without the use of matches or batteries. Natural Gas (.40 kPa) (.87 kPa) ACHES, DIZZINESS AND/OR NAUSEA. IF This system provides continued service in the (LO) 6.3” WC (H
ページ4に含まれる内容の要旨
QUESTIONS TO ASK LOCAL BUILDING FIREPLACE REQUIREMENTS 6. Maximum amount of gas pipe without a OFFICIAL pressure test - type of test required? IMPORTANT: When installing these appliances 7. Are below grade penetrations of the gas These appliances must be installed per into a factory built fi replace or heatform, the air line allowed? manufacturers’ instructions. Installations fl ow within and around the fi replace shall not 8. Is concealed gas piping allowed? be altered by the installation of
ページ5に含まれる内容の要旨
SPECIFICATIONS: EDVI25 DIMENSIONS SPECIFICATIONS EDVI25 EDVI25 Inches (millimeters) Min. / Max. BTU hr 17,000 to 25,000 A 26 5/8" (676 mm) Input - NG B 20 1/2" (521 mm) Min. / Max. BTU hr 19,000 to 25,000 C 5” (127 mm) Input - LP D SM.= 41 1/16” (1043 mm) & MED.= 44 1/8” (1121 mm) Co-linear DV Vent 3” Dia. Liner SM.= 26 1/16” (662 mm) & MED.= 27 5/8” (702 mm) Size (exhaust & intake) E 19 1/2” (483 mm) F Room Blower CFM 110 cfm G 1 15/16” (49 mm) H
ページ6に含まれる内容の要旨
SPECIFICATIONS: EDVI30 & EDVI35 DIMENSIONS SPECIFICATIONS EDVI30 EDVI35 EDVI30 EDVI35 Inches (millimeters) Inches (millimeters) Min. / Max. BTU/hr 21,500 to 30,000 25,500 to 35,000 25 15/16" (659 mm) A 32 1/16” (814 mm) Input - NG B 22 1/4" (578 mm) 24 3/16” (614 mm) Min. / Max. BTU/hr 22,000 to 28,000 26,000 to 34,000 5" (127 mm) 5" (127 mm) C Input - LP D 40 1/4” (1022 mm)Sm. Co-linear DV Vent 3” Dia. Liner 3” Dia. Liner 45 3/4” (1162 mm) Med. 48 1/16” (1221 mm) Med.
ページ7に含まれる内容の要旨
MINIMUM CLEARANCES TO COMBUSTIBLES: EDVI25, EDVI30 & EDVI35 These appliances can be installed in most residential fi replace confi gurations. If installed close to an adjacent Inches (millimeters) wall, ensure that the minimum clearances to combustible Clearances to Combustibles Min. EDVI25 EDVI30 EDVI35 Max. surfaces are maintained. A local building inspector should A Side Wall 8" (203 mm) 8" (203 mm) 8" (203 mm) Min. review your plans prior to installation. B Ceiling or Alcove Height 64"
ページ8に含まれる内容の要旨
Step 4 LIFT INSERT INTO POSITION (read MINIMUM FIREPLACE DIMENSIONS CAUTION: If any portion of the chimney Fireplace Requirements on page 4 fi rst) Lift Refer to Figures 7 and 8 for Minimum Fire- system shows signs of structural or mechani- insert into position in front of the fi replace where place Clearance Dimensions. See pages 5 & cal weaknesses, such as: cracks, leaky unit is to be installed. Discard bottom carton. 6 for actual insert body dimensions. joints, corroded or warped surface
ページ9に含まれる内容の要旨
STEP 6: REMOVE PACKAGED MATERIALS FROM INSIDE FIREBOX AND Simpson Dura Vent Components SET ASIDE (log set, bag of embers, bag of vermiculite, propane Part No. Description conversion kit - if needed to run on LP gas). 980 Termination Cap, Standard Step 7: INSTALL LP CONVERSION KIT (IF NECESSARY) - Install the 991 Termination Cap, High Wnd LP conversion kit per instructions provided with kit. 923GK Chimney Liner Term. Kit Step 8: VENTING SYSTEM INSTALLATION (Refer to Vent Ma
ページ10に含まれる内容の要旨
Factory Built Fireplace Installation Diagram Masonry Fireplace Installation Diagram The standard cap in Termination Kit, H0908, is a high wind cap Vertical Term- Masonry chimneys may take ination Cap various contours which the Vertical Termination Cap and Flashing. fl exible liners will accomodate. Cat. No. and Flashing, Cat. No. H0908 H0908 However, keep the fl exible liner Liner Requirements: as STRAIGHT as possible, avoid Exhaust Vertical Height Min. = 8 ft. (2.44 M) unnecessary bending
ページ11に含まれる内容の要旨
Flex Liner Installation (see Figure 14 for Step 10. PURGING AIR Masonry Fireplace Installations and Figure 15 for Factory Built Fireplaces): AIR PURGING PROCEDURES MUST BE PERFORMED BY A QUALIFIED TECHNICIAN Note: Refer to Vent Manufacturer Instal- ONLY. lation Instructions. Purging Air from Supply Line Screw a. Turn gas supply line valve off. 1) Cut the fl ex liners as required (mark both b. Loosen setscrew at inlet pressure tap on ends of one of the fl exible liners as INLET). control val
ページ12に含まれる内容の要旨
LOGS, VERMICULITE AND EMBERS - Models EDVI25 & EDVI30 (For 3. Place the Center Log onto the 2 corresponding locating pins as shown in Figure 22. EDVI35 Log Installation Instructions, see Page 13). The packaged log set, vermiculite and embers are located within the fi rebox of the insert. Installation Instructions: WARNING: IF LOGS ARE NOT INSTALLED ACCORDING TO THE DIRECTIONS SHOWN HERE, FLAME IMPINGEMENT AND IMPROPER COMBUSTION COULD OCCUR AND RESULT IN SOOT AND/OR EXCES- SIVE PRODUCTION OF
ページ13に含まれる内容の要旨
Figure 25 Front Center Log 7. Install the Top Right Log into the corresponding indentations on Embers Figure 27 Front Center Log and front right twig as shown in Figure 26. Figure 28 Vermiculite Top Right Log Figure 26 LOGS, VERMICULITE AND EMBERS - Model EDVI35 8. Place the glowing embers on the burner as shown in Figure 27. WARNING: IF LOGS ARE NOT INSTALLED ACCORDING TO THE DIRECTIONS SHOWN HERE, FLAME IMPINGEMENT AND IMPROPER One package of ember material has been included with this log
ページ14に含まれる内容の要旨
Rear Log Front Center Log Figure 32 Figure 29 Vermiculite 6. Install the Top Right Log into the corresponding indentations on Front Center Log and Front Right Log as shown in Figure 33. 3. Place the Front Right Log and the Center Left Log onto the 2 cor- responding locating pins (each) as shown in Figure 30. Top Right Log Figure 33 Center Left Log Front Right Log Figure 30 7. Place the glowing embers on the burner as shown in Figure 34. One package of ember material has been included with th
ページ15に含まれる内容の要旨
T O O W O L I P O N TH TH TP TP O L T H N Step 12. TEST ALL CONNECTIONS FOR Millivolt Appliance Checkout With gas line installed run initial system LEAKS (FACTORY AND FIELD). checkout before closing up the front of the The pilot fl ame should be steady, not lifting unit. Follow the pilot lighting instructions pro- Test For Gas Leaks or fl oating. Flame should be blue in color vided in the Homeowner's Care and Operation A. Mix a 50% dish soap, 50% water solution with traces of orange at the
ページ16に含まれる内容の要旨
Burner Flame Appearance Burner Air Shutter Adjustment Blower Wiring Diagram Adjusting Set Screw Adjustment Rod Up 120 V AC (1/8" Open Position) Burner Tube Power Cord Air Shutter Black Adjustment Rod Down (full open position) Figure 41 EDVI35 FACTORY AIR SHUTTER SETTING Sooting is indicated by black puffs developing INCHES (MILLIMETERS) at the tips of very long orange fl ames. Sooting Models Gas Type Air Shutter Gap results in black deposits forming on the logs, Fan Disc appliance inside s
ページ17に含まれる内容の要旨
SAFETY / LISTING LABELS - MODELS: EDVI30 & EDVI35 MODEL NO. EDVI30 MODEL NO. EDVI35 MANUFACTURED AT: Union City, TN MANUFACTURED AT: Union City, TN FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE 0-4500 FT/PI ALTITUDE 0-4500 FT/PI (0-1370M) (0-1370M) MIN. GAS SUPPLY PRESS (“WC) MIN. GAS SUPPLY PRESS (“WC) PRESS MIN. D’ALIMENTATION (“ CE) 4.5” PRESS MIN. D’ALIMENTATION (“ CE) 4.5” MANIFOLD PRESSURE (
ページ18に含まれる内容の要旨
SAFETY / LISTING LABEL - MODEL: EDVI25 MODEL NO. EDVI25 MANUFACTURED AT: Lynwood, CA FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE 0-4500 FT/PI (0-1370M) MIN. GAS SUPPLY PRESS (“WC) PRESS MIN. D’ALIMENTATION (“ CE) 4.5” MANIFOLD PRESSURE (“WC) PRESSION CE TUBULURE (“CE) 3.5” MANUFACTURER’S RECOMMENDED ORIFICE SIZE DIMENSION DE L’INJECTEUR RECOMMANDE PAR MANUFACTURIER (DMS) #41 MAX INPUT (BTU/HR) ENTREE MAX 25,000 MIN INPUT (BTU/HR) ENTREE MIN 17,000
ページ19に含まれる内容の要旨
19 NOTE: THIS PAGE LEFT BLANK INTENTIONALLY. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
ページ20に含まれる内容の要旨
Lennox reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information. Printed in U.S.A. © Lennox Hearth Products 2003 P/N 775,156M REV. G 3/2005 1110 West Taft Avenue Orange, CA 92865 20 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.