LEAVE IT WITH THE APPLIANCE FOR OPERATION AND MAINTENANCE.
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
- Do not store or use gasoline or other
flammable vapors
ページ2に含まれる内容の要旨
Table of Contents SERVICE PARTS LIST ............................................................................................................ 3 ! 1.0 INTRODUCTION .......................................................................................................... 15 2.0 ASSEMBLY ................................................................................................................. 15 GAS LINE CONNECTION .........................................................................
ページ3に含まれる内容の要旨
CFL-18-B Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7/98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 13 15 11 10 9 12 14 8 2 3 16 5 1 Part number list on following page. * 6 La liste des numéros de pièce se 7 * trouve à la page suivante. 4 Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 3
ページ4に含まれる内容の要旨
Service Parts List / Liste des pièces de rechange CFL-18-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une ITEM / SERIAL # PART NUMBER DESCRIPTION PIÈCE / N° DE SÉRIE / N
ページ5に含まれる内容の要旨
CFL-24-B Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7/98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 15 13 11 10 12 14 8 9 2 3 4 16 5 1 6 7 Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. * Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 5
ページ6に含まれる内容の要旨
Service Parts List / Liste des pièces de rechange CFL-24-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles po
ページ7に含まれる内容の要旨
CFL-30-B Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7/98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 13 15 14 16 11 8 9 10 12 8 9 2 3 4 17 5 1 6 7 Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. * Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 7
ページ8に含まれる内容の要旨
Service Parts List / Liste des pièces de rechange CFL-30-B IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles po
ページ9に含まれる内容の要旨
ST-CFL-24 Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 7-98 (GN, PL) Vue éclatée des pièces Ending Manufacturing Date: ______ 15 13 16 12 9 17 10 8 18 14 11 9 10 3 2 19 4 5 1 6 7 4 Part number list on following page. * La liste des numéros de pièce se trouve à la page suivante. * Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 9
ページ10に含まれる内容の要旨
Service Parts List / Liste des pièces de rechange ST-CFL-24 IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles p
ページ11に含まれる内容の要旨
Gas Log Positioning 19 1/2 MINIMUM FIREPLACE SIZE FRONT WIDTH : 23 1/2” (750mm) REAR WIDTH : 19 1/2” (521mm) 13 1/2 TOP VIEW DEPTH : 13 1/2” (331mm) HEIGHT : 22” (508mm) 23 1/2 FIGURE 1. MODEL CFL-18-B Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 11
ページ12に含まれる内容の要旨
Gas Log Positioning 22 MINIMUM FIREPLACE SIZE FRONT WIDTH : 27 1/2” (750mm) REAR WIDTH : 22” (521mm) 15 1/2 TOP VIEW DEPTH : 15 1/2” (331mm) HEIGHT : 22” (508mm) 27 1/2 FIGURE 2. MODEL CFL-24-B Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 12
ページ13に含まれる内容の要旨
Gas Log Positioning 24 MINIMUM FIREPLACE SIZE FRONT WIDTH : 30” (750mm) REAR WIDTH : 24” (521mm) TOP VIEW 15 1/2 DEPTH : 15 1/2” (331mm) HEIGHT : 22” (508mm) 30 FIGURE 3. MODEL CFL-30-B Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 13
ページ14に含まれる内容の要旨
Gas Log Positioning 24 MINIMUM FIREPLACE SIZE FRONT WIDTH : 24” (521mm) REAR WIDTH : 24” (521mm) 17 TOP VIEW DEPTH : 17” (331mm) HEIGHT : 20” (508mm) 24 FIGURE 4. MODEL ST-CFL-24 Heat & Glo • CFL-18/24/30-B, ST-CFL-24 • 526-900 Rev. F • 7/05 14
ページ15に含まれる内容の要旨
1.0 INTRODUCTION CAUTION: CHECK THE CONSTRUCTION OF The information in this manual pertains to Models CFL- 18 NG/LP-B, CFL-24 NG/LP-B, CFL-30 NG/LP-B and THE FIREPLACE BEFORE INSTALLING THE GAS ST-CFL-24NG/LP. LOG SET. THE AREA OF THE FLUE SHOULD NOT BE LESS THAN 1/11 THE AREA OF THE FIREPLACE Gas Log Sets are Decorative Gas Appliances for Instal- OPENING NON-AIRTIGHT GLASS DOORS SHOULD lation in a Solid-fuel Burning Fireplace. Minimum fire- BE INSTALLED ON THE FIREPLACE IF THE AREA place si
ページ16に含まれる内容の要旨
B. Minimum inlet gas supply pressure for purposes of WARNING: OPEN THE CHIMNEY DAMPER TO ITS input adjustment, shall be 7.0 inches w.c. (1.75kPa) FULLY OPEN POSITION WHEN BURNING THIS GAS for natural gas and 11.0 inches w.c. (2.75kPa) for pro- LOG SET. pane (LP gas). Maximum inlet gas supply pressure WARNING: LOGS MUST NEVER BE BURNED WITH- shall be 14.0 in. w.c. (3.5kPa) for both natural gas and OUT THE FLUE DAMPER IN THE FULL OPEN POSI- propane (LP gas). Manifold (outlet) pressure should TIO
ページ17に含まれる内容の要旨
3.0 OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS Upon completing the gas line connection, a small amount CFL-18-B of air will be in the lines. When first lighting the pilot CFL-24-B light, it will take a few minutes for the lines to purge CFL-30-B themselves of this air. Once the purging is complete, the pilot and burner will light and operate as indicated in the instruction manual. Subsequent lighting of the appliance will not require such purging. WARNING: ST-CFL24 Be sure fireplace scre
ページ18に含まれる内容の要旨
SAFETY INFORMATION FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH. A. This appliance has a pilot which must be C. Use only your hand to push in or turn the gas lighted by hand. When lighting the pilot, fol- control knob. Never use tools. If the knob will low these instructions exactly. not push in or turn by hand, don’t try to repair it, call a qualified service techn
ページ19に含まれる内容の要旨
LIGHTING INSTRUCTIONS LIGHTING INSTRUCTIONS 1. "STOP!" Read the safety information on previous THERMOPILE PILOT BURNER page. 2. Open the control access cover (logs #3 and 4 in CFL models) or (logs #4 and 5 in ST-CFL model), refer to your Log Placement Instructions. 3. Turn the valve control knob to the "OFF" 6. To put the control in the "Pilot" position, turn the position. To do this, you must turn the knob control knob counter-clockwise to the clockwise to the "Pilot" position, and "Pilo
ページ20に含まれる内容の要旨
4.0 HIGH ELEVATION INSTALLATION U.L. Listed gas appliances are tested and approved for elevations between 2000 and 4500 feet in Canada. without requiring changes for elevations from 0 to 2,000 If the heating value of the gas has been reduced, these feet in the U. S. A. and in Canada. rules do not apply. To identify the proper orifice size, check with the local gas utility. When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input If installing thi