Owner’s Manual
Installation and Operation
Model:
Cyclone-Cust
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
instructions is not followed exactly, a fi re
Glass and other surfaces are hot during
or explosion may result
ページ2に含まれる内容の要旨
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Heat & Glo gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Heat & Glo gas appliance you have selected is designed to provide the utmost in safety, The
ページ3に含まれる内容の要旨
Table of Contents 1 Listing and Code Approvals 9 Gas Information A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 B. Glass Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 C. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. G
ページ4に含まれる内容の要旨
Listing and Code Approvals 1 1 A. Appliance Certifi cation D. High Altitude Installations U.L. Listed gas appliances are tested and approved with- MODELS: Cyclone-Cust out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Fireplace When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rating STANDARD: ANSI Z21.50-2000 • CSA2.33-2000 • UL3
ページ5に含まれる内容の要旨
Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed H. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall
ページ6に含まれる内容の要旨
Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the out- Inspect appliance and components for damage. side. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. • Do NOT install incomplete components. CAUTI
ページ7に含まれる内容の要旨
Framing and Clearances 3 3 Note: WARNING • Illustrations reflect typical installations and are FOR Fire Risk DESIGN PURPOSES ONLY. Provide adequate clearance: • Illustrations/diagrams are not drawn to scale. • Around air openings • Actual installation may vary due to individual design preference. • To combustibles • For service access A. Selecting Appliance Location Locate appliance away from traffi c areas. When selecting a location for your appliance it is important to Note: For actual
ページ8に含まれる内容の要旨
B. Constructing the Appliance Chase A chase is a vertical boxlike structure built to enclose the gas appliance and/or its vent system. Vertical vents that run on the outside of a building may be, but are not re- quired to be, installed inside a chase. Construction of the chase may vary with the type of build- ing. These instructions are not substitutes for the require- ments of local building codes. Local building codes MUST be checked. Chases should be constructed in the manner of all out-
ページ9に含まれる内容の要旨
D. Mantel Projections SLIP SECTION FRAMING COMBUSTIBLE MEMBER MATERIAL GLASS FIRESTOP TUBE 34-3/8 in. TO CEILING AND/OR MANTEL TOP 41-3/8 in. OF UNIT (+0 to -1/2 in.) Figure 3.3 Clearances to mantels or other combustibles above appliance Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08 9
ページ10に含まれる内容の要旨
Termination Locations 4 4 HORIZONTAL A. Vent Termination Minimum Clearances OVERHANG 2 FT. 20 INCHES MIN. VERTICAL MIN. WALL WARNING LOWEST DISCHARGE OPENING Fire Risk. GAS DIRECT VENT TERMINATION CAP Explosion Risk. Inspect external vent cap regularly. X 12 • Ensure no debris blocks cap. • Combustible materials blocking cap may ROOF PITCH IS X/ 12 ignite. H (MIN.) - MINIMUM HEIGHT FROM ROOF • Restricted air fl ow affects burner operation. TO LOWEST DISCHARGE OPENING Roof Pitch H (Min.) Ft
ページ11に含まれる内容の要旨
M N P R Q (See Note 2) V T S S Electrical V V Service D* V = VENT TERMINAL X V = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED A = 12 inches.................clearances above grade, veranda, L** = 7 ft. ......................... clearance above paved (See Note 1) (See Note 1) porch, deck or balcony sidewalk or a paved driveway located on public property B = 12 inches.................clearances to window or door M*** = 18 inches................ clearance under veranda, porch, that
ページ12に含まれる内容の要旨
Vent Information and Diagrams 5 5 A. Vent Table Key The abbreviations listed in this vent table key are used in the vent diagrams. Symbol Description Vertical First section (closest to appliance) of vertical length V1 Second section of vertical length V2 First section (closest to appliance) of horizontal length H1 8-1/2 in. Second section of horizontal length H2 WARNING Horizontal Fire Hazard. Explosion Risk. Figure 5.1 Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue
ページ13に含まれる内容の要旨
D. Vent Diagrams WARNING Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • ALWAYS maintain specifi ed clearances around venting and fi restop systems. • Install wall shield and ceiling fi restops as specifi ed. Failure to keep insulation or other material away from vent pipe may cause fi re. 1. Top Vent - Horizontal Termination V Min. H Max. T T One Elbow 2 ft. 2 ft. NOTE: A minimum of 2 feet before 3 ft. 6 ft. the fi rst 90º elbow can be achieved
ページ14に含まれる内容の要旨
1. Top Vent - Horizontal Termination - (continued) V H V H V Min. H Max. 1 1 2 2 T T Three Elbows **** 2 ft. 2 ft. **** 3 ft. 6 ft. **** 4 ft. 10 ft. **** 5 ft. 15 ft. V + H = 40 ft. Max. T T *No specifi c restrictions on this value EXCEPT V + H cannot exceed 40 ft. Max. T T H T V T V 2 H 2 H 1 V 1 Figure 5.5 14 Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08
ページ15に含まれる内容の要旨
2. Top Vent - Vertical Termination CAP No Elbow V MAX. T 40 ft. SLIP SECTION Flue Restrictor FLUE Inside Max. Vertical RESTRICTOR Part No. Diameter (V ) T 2061-204 2-3/4 in. 15-30 ft. 2061-203 2-1/2 in. 30 ft. or more V T GLASS CYLINDER ASSEMBLY Drop the fl ue restrictor into the slip section as shown. Figure 5.6 V V V Min. H Max. 1 2 T T Two Elbows * * 2 ft. 2 ft. * * 3 ft. 6 ft. * * 4 ft. 10 ft. * * 5 ft. 15 ft. V + H = 40 ft. Max. T T *No specifi c restrictions on this value EXCEPT V + H ca
ページ16に含まれる内容の要旨
2. Top Vent - Vertical Termination - (continued) V H H V V Min. H Max. 1 1 2 2 T T Three Elbows **** 2 ft. 2 ft. **** 3 ft. 6 ft. **** 4 ft. 10 ft. **** 5 ft. 15 ft. V + H = 40 ft. Max. T T *No specifi c restrictions on this value EXCEPT V + H cannot exceed 40 ft. Max. T T V T V 2 H T H 2 H 1 V 1 Figure 5.8 16 Heat & Glo • Cyclone-Cust • 2061-900 Rev. L • 10/08
ページ17に含まれる内容の要旨
Vent Clearances and Framing 6 6 A. Pipe Clearances to Combustibles B. Wall Penetration Framing Combustible Wall Penetration WARNING Frame a hole in a combustible wall for an interior wall shield fi restop, (Figure 6.2) whenever a wall is penetrated. Fire Risk. Use same size framing materials as those used in the wall Explosion Risk. construction. The wall shield fi restop maintains minimum Maintain vent clearance to combustibles as clearances and prevents cold air infi ltration. specifi ed.
ページ18に含まれる内容の要旨
C. Vertical Penetration Framing WARNING Fire Hazard Keep loose materials or blown insulation from touching the ATTIC ABOVE vent pipe. • National building codes recommend using attic shield to keep loose materials/ blown insulation from contacting vent. • Hearth & Home Technologies requires 10 IN. (254 MM) the use of an attic shield. Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/fl oor (see Figure 6.3). • Frame the
ページ19に含まれる内容の要旨
Appliance Preparation 7 7 A. Securing and Leveling the Appliance SCREW HOLES PROVIDED FOR SECURING WARNING Fire Risk. • Prevent contact with sagging, loose insulation. • Do NOT install against combustible materials such as exposed insulation, plastic and insulation backer. The diagram shows how to properly position, level, and secure the appliance (see Figure 7.1). Holes are provided to secure the appliance to the framing members with screws. • Horizontal venting - refer to Vent Clearan
ページ20に含まれる内容の要旨
Installing Vent Pipe 8 8 Commercial, Multi-family (Multi-level exceeding two A. Assembly of Vent Sections stories), & High-Rise Applications WARNING For Installation into Commercial, multi-family (multi-level ex- ceeding two stories) or high-rise applications: All pipe joints Do not mix pipe, fi ttings or joining must be sealed with high temperature silicone, including the methods from different manufacturers. slip section that connects directly to the horizontal termina- tion cap, but no