ページ1に含まれる内容の要旨
www.hampton-fi re.com
Owners &
H15 Direct Vent Gas Fireplace
Installation Manual
MODELS: H15-NG1 Natural Gas H15-LP1 Propane
WARNING: FOR YOUR SAFETY This appliance may only be
If the information in these instructions are not installed in an aftermarket
followed exactly, a fi re or explosion may result What to do if you smell gas: permanently located, manu-
causing property damage, personal injury or loss Do not try to light any appliance factured (USA only) or mobile
of life.
ページ2に含まれる内容の要旨
® HAMPTON Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! ® You are the owner of a state-of-the-art Hampton Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The H15-1 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fi replace at the fl ick of a switch. The model H15-1 has been approved by Warnock Hersey for both safety and effi ciency. As it also bears our own mark, it promises to provide you with economy,
ページ3に含まれる内容の要旨
TABLE OF CONTENTS Optional Wall Thermostat ...........................................34 SAFETY LABEL Optional Remote Control ............................................34 Final Check .................................................................34 Safety Label ..................................................................4 Wiring Diagrams ..........................................................35 Operating Instructions .................................................37 REQUIREMENTS
ページ4に含まれる内容の要旨
SAFETY LABEL ® This is a copy of the label that accompanies NOTE: Hampton units are constantly being each Direct Vent Freestanding Gas Stove. improved. Check the label on the unit and if We have printed a copy of the contents here there is a difference, the label on the unit is for your review. the correct one. For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts. For the State of Massachusetts, fl exi
ページ5に含まれる内容の要旨
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished gr
ページ6に含まれる内容の要旨
INSTALLATION This appliance installation must comply with the IMPORTANT MESSAGE WARNING: FAILURE TO INSTALL manufacturer's installation instructions and local THIS APPLIANCE CORRECTLY codes, if any. In the absence of local codes fol- SAVE THESE low the current National Fuel Gas Code, ANSI WILL VOID YOUR WARRANTY INSTRUCTIONS Z223.1 and the current National Electrical Code AND MAY CAUSE A SERIOUS ANSI/NFPA 70 in the U.S.A., and the current HOUSE FIRE. The Direct Vent Freestanding Gas S
ページ7に含まれる内容の要旨
INSTALLATION (825mm), a maximum depth of 36" (914mm), INSTALLATION CLEARANCES TO and minimum height of 24" (610mm) from top of unit to ceiling. CHECKLIST COMBUSTIBLES 6) We recommend that you plan your instal- 1) Locate your gas appliance. Refer to the The clearances listed are MINIMUM distances. lation on paper using exact measurements following sections: Measure the clearance to both the appliance for clearances and fl oor protection before and the chimney connector. The farthest actu
ページ8に含まれる内容の要旨
INSTALLATION 4) Remove the nylon hole plug from the control OPTIONAL FAN LOCATING YOUR panel. GAS STOVE INSTALLATION 5) Install the fan speed controller onto the control panel and secure with nut and Fan Kit Contains: When selecting a location for your stove, ensure washer. Connect the red and black wires that the clearances listed above are met as well from the wire harness to speed controller. Qty. Description as ensuring that there is adequate accessibility NOTE: Speed control wir
ページ9に含まれる内容の要旨
INSTALLATION 12) Slide fan into place and secure with the two 14) Connect fan ground wire to lug nut at base 9) Remove 2 screws from unit. screws removed in step 9. of unit. Lug Nut 10) Place grommet in rear plate through the bottom of the opening as shown below. 13) Connect long black & red wires to thermodisc 15) Before re-attaching the rear access panel, and secure wires. the valve wires and the fan wires need to be connected. Re-connect the red and grey valve wires removed in step 2. R
ページ10に含まれる内容の要旨
INSTALLATION VENTING INSTALLATION SAFETY PRECAUTIONS INTRODUCTION PRECAUTIONS FOR THE INSTALLER The Horizontal Termination Kit and the Simpson These venting systems are engineered products 1) Wear gloves and safety glasses for protec- Dura-Vent Direct Vent System Model DV-GS that have been designed and tested for use tion. venting systems, in combination with the Direct with the H15-NG1, and H15-LP1. The warranty Vent Freestanding Gas Stoves, H15-NG1, and will be voided and serious fi re, he
ページ11に含まれる内容の要旨
INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS A= Clearance above grade, veranda, porch, deck, or balcony *(min. 12"/30cm) B= Clearance to window or door that may be opened *(12"/30cm) C= Clearance to permanently closed window *(min. 12"/30cm) D= Vertical clearance to ventilated soffi t located above the terminal within a horizontal distance of (24"/60cm) from the centerline of the terminal (min. 22"/55cm) check with local code. E= Clearance to unventilated soffi t (min. 12"/30cm) F= Clearance t
ページ12に含まれる内容の要旨
INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Simpson American Metal ® Simpson Metal-Fab Security ® Selkirk ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 6” Pipe Length, Galvanized 46DVA-06 908 4DT-6 N/A 4D6 SV4L6 6” Pipe Length, Black 46DVA-06B 908B 4DT-6B N/A 4D6B SV4LB6 7” Pipe Leng
ページ13に含まれる内容の要旨
INSTALLATION 4” x 6-5/8” Rigid Pipe Cross Reference Chart (Cont.) Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI. Simpson American Metal ® Simpson Metal-Fab Security ® Selkirk ® Direct Vent GS Description Products ® ® Direct Vent Pro Sure Seal Secure Vent Direct-Temp™ Amerivent Direct Discontinued 46DVA-IS - N/A from FPI N/A N/A 4DAIS12 N/A SV4RSA Attic Insulation Shield 12” Attic Insulation Shield - Cold Climates 36” N/
ページ14に含まれる内容の要旨
INSTALLATION RIGID PIPE VENTING SYSTEMS Horizontal or Vertical Terminations Alternate Vertical Horizontal Termination Termination Cap Caps Storm Collar Vinyl Siding Standoff (Optional) Flashing Horizontal Termination Ceiling Firestop Cap Wall Thimble Pipe Length Adj.Pipe Length 11" - 14-5/8" o 90 Elbow WARNING: Do not combine venting components from 24" Pipe different venting systems. Length TM However use of the the AstroCap and FPI Riser is acceptable with all systems. This product has been
ページ15に含まれる内容の要旨
INSTALLATION o Horizontal Venting with Two (2) 90 Elbows o o One 90 elbow = Two 45 elbows. Option V H + H1 With these options, maxi- A) 1' Min. 3' Max. mum total pipe length is 30 feet with minimum of 6 feet B) 2' Min. 4' Max. total vertical and maximum C) 3' Min. 5' Max. 8 feet total horizontal. D) 4' Min. 6' Max. Please note minimum 1 o E) 5' Min. 7' Max. foot between 90 elbows is required. F) 6' Min. 8' Max.
ページ16に含まれる内容の要旨
INSTALLATION o Vertical Venting with Two (2) 90 Elbows o o One 90 elbow = Two 45 elbows. Option V H V + V1 With these options, max. total pipe length is 30 feet with min. A) 1' Min. 4' Max. 2' Min. of 6 feet total vertical and max. B) 2' Min. 5' Max. 3' Min. 8 feet total horizontal. C) 3' Min. 6' Max. 4' Min. Please note min. 1 foot o D) 4' Min. 7' Max. 5' Min. between 90 elbows is re- quired. E) 5' Min. 8' Max. 6' Min. V1 Lengths do not include elbow
ページ17に含まれる内容の要旨
INSTALLATION VENTING ARRANGEMENTS Horizontal Terminations for Vertical Terminations Systems for All Venting Systems Residential Manufactured and Mobile Homes The shaded areas in the diagram below show all The shaded area in the diagram below shows all allowable combinations of straight o vertical and offset to vertical runs with vertical terminations. Maximum two 45 allowable combinations of vertical runs with hori- O zontal terminations. Maximum one 90 elbow (two elbows. o o 45 elbows equa
ページ18に含まれる内容の要旨
INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the fl exible liner will accommodate. However, THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE keep the fl exible liner as straight as possible, avoid unnecessary bending. SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. The Air Intake pipe must be attached to the inlet air collar of the termination cap. This appliance is designed to be attached to Alternate Approved Caps Require
ページ19に含まれる内容の要旨
INSTALLATION DV STOVE HORIZONTAL VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the H15-1 Direct Vent unit with up & out horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown in the "Dura-Vent Termina- tion Kit" and "Dura-Vent Venting Components" sections. Qty. Description 1) 1 Rigid Pipe Section (Kit # 946-116: 2 f
ページ20に含まれる内容の要旨
INSTALLATION 9) Secure the 4" dia. fl ex liner to the 4" adapter with Mill-Pac and 3 of the #8 x 1/2" screws (stainless steel). 10) Slide the decorative Thimble Cover over the pipe sections and secure with 4 screws (#8 x 1-1/2" drill point, black) to the wall. o o 11) Slide the 90 elbow (crimp end up), the 45 elbow and the 4 ft. pipe section (crimp end up) over the 4" dia. fl ex liner. 12) Install the spring spacers onto the pipe sections. 13) Secure the 4" dia. fl ex liner with adapter on