ページ1に含まれる内容の要旨
GF55 & GFI55
OWNER'S MANUAL
Freestanding and Fireplace
Insert Pellet Stove
WARNING: FOR YOUR SAFETY:
Improper installation, adjustment, alteration, Do not store or use gasoline or other fl ammable
service or maintenance can cause vapours and liquids in the vicinity of this or any other
injury, property damage, or loss of life. appliance.
Refer to this manual. For assistance or
Installation and service must be performed by an
additional information consult an authorized
authorized installe
ページ2に含まれる内容の要旨
TO THE NEW OWNER Congratulations! You are the owner of a state-of-the-art Pellet Stove. Thank-you for purchasing a FPI FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the GREENFIRE DEALER in your area. Safety Note: If this stove is not properly installed, a house fi re may result. For your safety, follow the ins
ページ3に含まれる内容の要旨
TABLE OF CONTENTS SAFETY LABEL MAINTENANCE Copy of Serial No. Decal ...............................................4 Routine Cleaning & Maintenance ................................10 Opening the Door ...................................................10 Burn Pot & Liner .....................................................10 INSTALLATION Door Glass Cleaning ..............................................10 Ash Pan & Door Gaskets ........................................10 Safet
ページ4に含まれる内容の要旨
Sidewall Adjacent wall SAFETY LABEL This is a copy of the label that accom- panies each GF55 & GFI55. We have printed a copy of the contents here for your reference. On the GF55 the safety label is located on the underside of the hopper lid. On the GFI55 the safety label is located on the hopper cover behind the top faceplate. 4 Greenfi re Pellet Stove and Insert Owner's Manual INSTALLATION Model / Modèle: DO NOT REMOVE THIS LABEL / NE RETIREZ PAS CETTE ÉTIQUETTE 334 Greenfire GF55 (St
ページ5に含まれる内容の要旨
INSTALLATION INSTALLATION SAFETY WARNINGS & RECOMMENDATIONS CAUTION: SMOKE DETECTOR: Smoke detectors should be installed and Do not connect to any air distribution duct or system. maintained in the structure when installing and operating a pellet burning Do not burn garbage or fl ammable fl uids such as gasoline, appliance. naptha or engine oil. Unit hot while in operation. Keep children, clothing and fur- OPERATION: The ash pan and door must be closed securely for proper niture away. Contact
ページ6に含まれる内容の要旨
INSTALLATION PELLET QUALITY IMPORTANT SAFETY INFORMATION Pellet quality is important, please read the following: Please read this entire Owner’s Manual before installation and op- erating your Greenfi re Pellet Stove. Failure to follow these instruc- Pellet quality is a major factor in how the Pellet stove will operate. tions may result in property damage, bodily injury or even death. If the pellets have a high moisture or ash content the fire will be less efficient and has a higher possibilit
ページ7に含まれる内容の要旨
OPERATION OPERATING INSTRUCTIONS CONTROL BOARD FUNCTIONS 1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim button until the number 1 and 5 lights appear HIGH/LOW on the Heat Level Indicator. This will increase the feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow AUTO/OFF MANUAL the burning of poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On time to 2
ページ8に含まれる内容の要旨
OPERATING INSTRUCTIONS OPERATING YOUR PELLET STOVE PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit. Note: The thermostat mode can be changed during normal operation. DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. MANUAL MODE HIGH / LOW MODE (Requires a thermostat) (No thermostat) INITIAL START-UP: See "manual mode". All control of circui
ページ9に含まれる内容の要旨
OPERATION OPERATING INSTRUCTIONS SLIDER / DAMPER SET-UP THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION. A Qualified Service Technician or Installer must set the Slider Damper. This is used to regulate the airflow through the pellet stove. The slider damper knob is located on the left cab side (see Figure 7). Figure 8: Effi cient Flame. SPECIAL NOTES: Pellet quality is a major factor in how the Pellet stove will operate. If the pellets have a high moisture or ash content the fire wil
ページ10に含まれる内容の要旨
MAINTENANCE ROUTINE CLEANING & MAINTENANCE The following list of components should be inspected and maintained If after long periods of burning, the fi re continually builds up and overfl ows routinely to ensure that the appliance is operating at its optimum and the burn pot or there is a build up of clinkers, this is an indication that giving you excellent heat value: the pellet fuel quality is poor or the stove may need cleaning. Check the stove for ash build up (clean if required) and adj
ページ11に含まれる内容の要旨
MAINTENANCE MAINTENANCE ASH PAN FRESH AIR INTAKE (weekly) (season) The ash pan is located under the burner. Always dispose of the ashes into Inspect periodically to be sure that the intake pipe is not clogged with any a metal container (never use cardboard, plastic or wood containers) stored foreign materials. away from combustibles. Monitor the ash level every week. Remember different pellet fuels will have different ash contents. Ash content is a good indication of fuel effi ciency and q
ページ12に含まれる内容の要旨
MAINTENANCE EXHAUST PASSAGES POST SEASON CLEAN-UP (season) Once you are fi nished using the pellet appliance for the season, unplug the stove for added electrical protection. It is very important that the stove Removal of the firebox backing for bi-annual cleaning (refer to be cleaned and serviced as stated above. Also remove any remaining fuel Figure 12): from the hopper and auger. a) Open the door by lifting the handle, remove the burn pot and burn pot liner. CLEANING PLATED SURFACES b)
ページ13に含まれる内容の要旨
WARRANTY FPI is the manufacturer of the Greenfi re line of heating products. At FPI, our commitment to the highest level of quality and customer service is the most important thing we do. Each Greenfi re stove is built on a tradition of using only the fi nest materials and is backed by our Exclusive Lifetime Limited Warranty to the original purchaser. With Greenfi re, you’re not just buying a stove, you’re buying a company with years of unequalled performance and quality. Limited Lifetime Warrant
ページ14に含まれる内容の要旨
WARRANTY Exclusions and Limitations: 1. This Warranty does not cover tarnish, discoloration or wear on the plating or paint. 2. This Warranty excludes wear and tear or breakage caused by cleaning, moving or service on log set. 3. A qualifi ed installer must install this stove or fi replace. This Limited Warranty covers defects in materials and workmanship only if the product has been installed in accordance with local building and fi re codes; in their absence, refer to the owner’s manual. I
ページ15に含まれる内容の要旨
WARRANTY 17. Damage to plated surfaces caused by fi ngerprints, scratches, melted items, or other external scores and residues left on the plated surfaces from the use of abrasive cleaners or polishes is not covered in this warranty. 18. The Limited Warranty does not cover tarnish, discoloration or wear on the plated surfaces. 19. The paint on the Metal Brick Liner may peel. This is due to the extreme conditions applied to the paint during normal usage. It is not a fl aw and is not covered unde
ページ16に含まれる内容の要旨
FPI fi replaces are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door. FPI Fireplace Products International Ltd. is pleased to extend this Limited Lifetime Warranty to the original purchaser of a FPI Product. Installer: Please complete the following information Dealer Name & Address: ______________________________________________ _____________________________________________