ページ1に含まれる内容の要旨
SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER.
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Westport
B Y : S H E R W O O D I N D U S T R I E S L T D
OWNER’S MANUAL
INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WHAT TO DO IF YOU SMELL GAS
• Open windows/extinguish any open
flame.
• Do not try to light any appliance.
• Do not touch any electrical switch
or use any phone in your
ページ2に含まれる内容の要旨
Safety Precautions FOR SAFE INSTALLATION AND OPERATION OF YOUR “ENVIRO” HEATER, PLEASE CAREFULLY READ THE FOLLOWING INFORMATION: • All ENVIRO gas-fired appliances must be installed • To prevent injury, do not allow anyone who is in accordance with their instructions. Carefully read all unfamiliar with the stove to operate it. the instructions in this manual first. Consult the building • To prevent injury, if the pilot or pilot and authority having jurisdiction to determine the need for burn
ページ3に含まれる内容の要旨
Table of Contents Safety Precautions..................................................................................................................2 Table of Contents...................................................................................................................3 Codes And Approvals..............................................................................................................4 Specifications.....................................................................
ページ4に含まれる内容の要旨
Codes And Approvals DIRECT VENT ONLY: This type is identified by the sufix DV. This appliance draws all of its air for combustion from outside the dwelling, through a specially designed vent pipe system. TOP VENT DV Certified for installation from 0-4500 ft (0-1372 m) REAR VENT DV Certified for installation from 0-4500 ft (0-1372 m) with 36” (915 mm) snorkel (refer to ‘Converting Top Vented into Rear Vented’). In the USA: The appliance may be installed at higher altitudes. Please refer to y
ページ5に含まれる内容の要旨
Specifications WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. DIMENSIONS: 1 1 5 / 8 " 2 5 3⁄4 " ( 3 9.0 cm ) ( 6 5 .3cm ) 2 7" 2 7" ( 6 8 . 5cm ) ( 68.6 cm ) 1 5 3⁄4 " 25 3⁄4 " ( 4 0 .0c m ) ( 6 5 . 4cm ) 1 17 / 8 " ( 4 3 .5c m ) F l o o r t o c e nt e r o f fl u e 5 16 / 8 " R E A R V E N T ( 42 . 2cm ) 231⁄2 ” ( 59 . 7 cm ) 2 5 3⁄4 " ( 65.3 c m ) Figure 1: Westport Ext
ページ6に含まれる内容の要旨
I P F F H OT W H I L E O P E R A T IN G. D O N OT T OU C H . K E E P C H I L D R E N , C L OT H I N G , F U R N I T U R E , C A U T I O N : G A S O L IN E , O R O T H E R F L A M M A B L E V A P O U R S A W A Y . F O R Y OU R S A F E T Y : D o not op e r a t e thi s f i r ep l a c e w i t h t he g l ass r e m o ved , c r acke d, o r b r oken . R epl a c em en t o f th i s g l as s s h o ul d b e i nstal l e d w i th p r o vi si ons for co m bus ti on a n d by a l i cen s e d o r q ual i fi ed pe
ページ7に含まれる内容の要旨
Operating Instructions PILOT LIGHT: 1. Turn off the gas to the fireplace. If not recently done, remove the glass and let the unit air out for at least five (5) minutes to clear out any gas. Turn on gas to the heater. Leak test all joints with soapy water. NEVER USE OPEN FLAME FOR LEAK TESTING. 2. Start the pilot by pressing the gas control knob and turning it to PILOT. While holding the gas control knob in, press the piezo ignitor several � � � � � � � � �� � � � � � � � � � � � � times u
ページ8に含まれる内容の要旨
Operating Instructions For Your Safety, Read Safety Precautions And Lighting Instructions Before Operating REMOTE CONTROLS (OPTIONAL): This fireplace can use an optional remote control or an optional cordless wall thermostat. If either of these are to be used to control the fireplace for the majority of the time, leave the ON/OFF switch (on the control panel) in the remote/thermostat position. Consult the instructions included with the remote/wall thermostat for operation guidelines. BLOWE
ページ9に含まれる内容の要旨
Maintenance And Service ROUTINE MAINTENANCE: At least once a year, run through the following procedures to ensure the system is clean and working properly. Check the burner to see if all the ports are clear and clean. Check the pilot to make sure it is not blocked by anything. The pilot flame should be blue with little or no yellow on the tips. Warning: Clearances must be sufficient to allow access for maintenance and service Warning: Failure to position the parts in accordance with this manua
ページ10に含まれる内容の要旨
Maintenance And Service REPLACING THE GLASS: The glass in the fireplace is a high temperature ceramic. If the glass is damaged in any way, a factory replacement is required (see PARTS LIST - COMPONENTS). Wear gloves when handling damaged glass door assembly to prevent personal injury. When the glass door assembly is being transported, it must be wrapped in newsprint and tape and/or a strong plastic bag. Do not operate with the glass front removed, cracked or broken. Removal and replacemen
ページ11に含まれる内容の要旨
Maintenance And Service FUEL CONVERSION: TO BE INSTALLED BY A QUALIFIED SERVICE AGENCY ONLY Please read and understand these instructions before installing. Warning: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result c
ページ12に含まれる内容の要旨
Maintenance And Service 6. Convert the pilot injector: a) Pull the pilot hood straight up to access the pilot injector. 5 b) Using a /32” or 4 mm Allen key, L o o s e n remove the pilot injector. T i g h t e n c) Install the new pilot injector supplied with this conversion kit. Simply screw the new injector inside the pilot hood using the Allen key, d) Reinstall the hood by placing the hood on the assembly, line up the key way, and snap into place. Figure 9: Removing valve 7. Convert
ページ13に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. PREPARATION FOR INSTALLATION: • Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible. • Before beginning, carefully check the glass door and the log set
ページ14に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY R o u nd S up por t Your total vent pipe length must be within the B ox/ W a l l T h i m b l e shaded area of Figure 23. If a 90° elbow is used in the horizontal plane, 36” (91.4 cm) must be subtracted from the allowable horizontal run. There are three (3) basic types of Direct Vent H or i z o nta l T e r m i na ti o n System installations. The three (3) types of installations are shown in Figures 15 through 17. P i pel en g t h 9 0° E l b o
ページ15に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY VENT TERMINATION RESTRICTIONS: N O H D E B C B F i x e d B G C l os e d L F i x e d O pe n a b l e F Cl ose d G O p e na b l e M J K B A I A Te r m i na t i o n C a p A i r S u p p l y I nl e t R e s tr i cti o n Z o n e G G a s M e te r ( T e r m i na t i o n n o t a l l o w e d ) Figure 18. Vent Termination Restrictions, refer to Table 3. Table 3: Vent termination clearances, refer to Figure 18. 1 2 Letter Canadian Installation US Installation De
ページ16に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY FIREPLACE HORIZONTAL VENT KIT 50-1235: Please read and understand these instructions before installing. Failure to follow these instructions carefully could cause property damage or personal injury. KIT COMPONENTS: Qnty Description Qnty Description 1 Horizontal direct vent termination cap 4 Wire spacers 1 Flue collar adapter 1 4 oz tube Mill-Pac Sealant 1 Wall thimble 1 4 oz tube RTV silicone 9 1 5’ (190 cm) length of Ø4” (10 cm) double walled fle
ページ17に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY 10. Apply a bead of Mill-Pac Black sealant to H o r i z o nt al V e n t T e r m i nati o n the top section of the Ø4” (10 cm) by 5” (12.5 cm) flue collar adaptor previously installed into the fireplace flue outlet. Slide the Ø4” (10 cm) flex vent over the flue collar and secure with three (3) sheet metal screws evenly spaced. 11. Place a bead of high temperature silicone on the intake collar of the W al l F r ami n g fireplace, slide the Ø6
ページ18に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY EXCEPTION TO WARNING: This product has been evaluated by Intertek for using a Direct Vent GS starting collar in conjunction with Secure Vent, Direct-Temp, and Ameri Vent Direct venting systems. Use of these systems with the Direct Vent GS starting collar is deemed acceptable and does not affect the Intertek WH listing of the appliance. Table 5: Vent part numbers (Must state if galvanized or black wanted, PART NUMBERS). Direct Vent GS Direct-Tem
ページ19に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY VENT CONFIGURATIONS AND RESTRICTOR SETTINGS: Figures 23 & 24 show the range of venting options, they show possible vent configurations if the unit is top vented (see Figure 23) or rear vented (see Figure 24), for vertical and horizontal terminations, any layout that remains within the shaded area is acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 45˚ elbows is preferable to using 90˚ elbows. Al
ページ20に含まれる内容の要旨
Initial Installation QUALIFIED INSTALLERS ONLY HORIZONTAL INSTALLATION: 1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the way when the venting system is attached. If this is the case, you may want to adjust the location of the appliance. 2. Direct vent pipe and fittings are designed with special twist-lock connections. Assemble the desired combination of black pipe and elbows to the appliance adapter with pipe seams oriented towards F