ページ1に含まれる内容の要旨
operating Instructions & Parts Manual PC1 and PC2 Series
Please read and save these instructions. Read carefully before attemptingto assemble, install, operate or maintain the productdescribed.
Protect yourself and othersby observing all safety information. Failureto complywith instructions could result inpersonal injury and/or
property damage! Retain instructions for future reference.
Self-Priming
Transfer Pumps
Table of Contents Unpacking General Safety Information
ページ2に含まれる内容の要旨
Operating . Instructions . and . Parts . Manual 6 . .The . inlet . or . suction . hose . should . Installation IMPor Tan T BaTTery not . be . longer . than . 15 . feet; . and . Infor MaTIon the . vertical . distance . between . the . Models . PC1 . and . PC2 . include . a . 6 . foot . Be . certain . that . the . area . around . the . pump . and . the . water . level . should . long . suction . hose, . a . water . suction . batteries . is . well . ventilated .B .efore . not . be . any . higher .
ページ3に含まれる内容の要旨
PC1 and PC2 Series operation (Continued) 4 . .Connect . pump . to . power . source, . 12 VOLT WIRING DIAGRAM with . pump . in . a . dry . location .M . odel . PC1: . Motor . must . be . connected . to . a . fully . charged . automotive . tractor . or . marine . type . battery . to . operate . . . BLACK CLAMP TO NEGATIVE TERMINAL Grounding .Plug OUTLET INLET RED CLAMP TO POSITIVE TERMINAL + - TEST RESET POS NEG 12 VOLT DC BATTERY figure 1 12 VOLT DC PUMP . Connect . the . red . clamp . to . the
ページ4に含まれる内容の要旨
Operating . Instructions . and . Parts . Manual Troubleshooting Chart Symptom Possible Cause(s) Corrective a ction Pump . will . not . start . or . run 1 .B .lown . fuse 1 .I . f . blown, . replace . with . proper . sized . fuse . or . reset . breaker 2 .L .ow . line . voltage 2 .V .oltage . of . power . supply . must . match . the . voltage . of . the . pump 3 .W . orn . brushes 3 .R .eplace . brushes 4 .I . mpeller . blocked 4 .R .emove . blockage 5 .M . otor . has . overheated . . (Model . PC
ページ5に含まれる内容の要旨
PC1 and PC2 Series notes www.waynepumps.com 5
ページ6に含まれる内容の要旨
Operating . Instructions . and . Parts . Manual For Replacement Parts or Technical Assistance, Call 1-800-237-0987 Please provide following information: Address any correspondence to: - . Model . number . Wayne . Water . Systems . . - . Serial . number . (if . any) . 101 . Production . Drive - . Part . description . and . number . as . shown . in . parts . list . Harrison, . OH . . 4 . 5030 . . U . . S . A . figure – r eplacement Parts Illustration for Self-Priming Transfer Pumps www.
ページ7に含まれる内容の要旨
PC1 and PC2 Series r eplacement Parts l ist for Self-Priming Transfer Pumps r eference Part number for Models: number Description PC1 PC2 Quantity . 1 . Brush . and . Impeller . Kit . . 66062-WYN1 . 66058-WYN1 . A . . Impeller . 1 . . B . . Gasket . 2 . C . . Shaft .S .eal . 1 . D . . Retaining . Ring . 1 . E . . Brushes . 2 . 2 . Brush . Kit . . 66063-WYN1 . — . E . . Brushes . 2 . 3 . Water . Suction . Attachment . . 66064-WYN1 . 66064-WYN1 . F . . Water . Suction . Attachment .
ページ8に含まれる内容の要旨
Operating . Instructions . and . Parts . Manual limited w arranty For . one . year . from . the . date . of . purchase, . Wayne . Water . Systems . (“Wayne”) . will . repair . or . replace, . at . its . option, . for . the . original . purchaser . any . part . or . parts . of . its . Sump . Pumps . or . Water . Pumps . (“Product”) . found . upon . examination . by .Wayne .to .be .defective .in .materials .or .workmanship . . Please .call .Wayne .(800-237-0987) .for .instructions .or .see . your