ページ1に含まれる内容の要旨
OPERATION AND PARTS MANUAL
MULTIQUIP
MODEL QP-204H
CENTRIFUGAL PUMP
(Honda Gasoline Engine)
Revision #3 (06/05/06)
To find the latest revision of this
publication, visit our website at:
www.multiquip.com
THIS MANUAL MUST ACCOMPANY THE EQUIPMENT AT ALL TIMES.
ページ2に含まれる内容の要旨
PAGE 2 — QP-204H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL — REV. #3 (06/05/06)
ページ3に含まれる内容の要旨
NOTE PAGE QP-204H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL— REV. #3 (06/05/06) — PAGE 3
ページ4に含まれる内容の要旨
TABLE OF CONTENTS QP-204H Gasoline Honda GX120K1PX2/ Powered Centrifugal GX120U1PX2 Engines Air Cleaner (Dual) Assembly.............................. 32-33 Pump Camshaft Assembly ........................................... 34-35 Proposition 65 Warning ............................................. 2 Carburetor Assembly ......................................... 36-37 Table of Contents ...................................................... 4 Control Assembly ........................................
ページ5に含まれる内容の要旨
st Effective: June 1 , 2005 PARTS ORDERING PROCEDURES Ordering parts has never been easier! Choose from three easy options: Best Deal! Order via Internet (Dealers Only): If you have an MQ Account, to obtain a Order parts on-line using Multiquip’s SmartEquip website! Username and Password, E-mail us at: parts@multiquip.com. ■ View Parts Diagrams To obtain an MQ Account, contact your ■ Order Parts District Sales Manager for more information. ■ Print Specification Information Use the internet and q
ページ6に含まれる内容の要旨
QP-204H — SAFETY MESSAGE ALERT SYMBOLS Potential hazards associated with the operation of this FOR YOUR SAFETY AND THE SAFETY OF OTHERS! equipment will be referenced with Hazard Symbols which Safety precautions should be followed appear throughout this manual, and will be referenced in at all times when operating this conjunction with Safety Message Alert Symbols. equipment. Failure to read and understand the Safety Messages and HAZARD SYMBOLS Operating Instructions could result in injury to you
ページ7に含まれる内容の要旨
QP-204H — SAFETY MESSAGE ALERT SYMBOLS CAUTION - Rotating Parts CAUTION - Equipment Damage Messages NEVER operate equipment with covers, Other important messages are provided throughout this or guards removed. Keep fingers, hands, manual to help prevent damage to your pump, other hair and clothing away from all moving property, or the surrounding environment. parts to prevent injury. CAUTION - Accidental Starting ALWAYS place the engine ON/OFF This pump, other property, or the switch in the OFF
ページ8に含まれる内容の要旨
QP-204H — RULES FOR SAFE OPERATION ■ NEVER touch the hot exhaust manifold, DANGER DANGER DANGER DANGER DANGER muffler or cylinder. Allow these parts to cool before servicing engine or plate Failure to follow instructions in this manual may lead to compactor. serious injury or even death! This equipment is to be operated by trained and qualified personnel only! This equipment is for industrial use only. The following safety guidelines should always be used when ■ High Temperatures – Allow the en
ページ9に含まれる内容の要旨
QP-204H — RULES FOR SAFE OPERATION ■ NEVER run engine without air cleaner. Severe engine damage Maintenance Safety: may occur. ■ NEVER lubricate components or attempt service on a ■ ALWAYS read, understand, and follow procedures in running machine. Operator’s Manual before attempting to operate equipment. ■ ALWAYS allow the machine a proper amount of time to ■ ALWAYS be sure the operator is familiar with proper safety cool before servicing. precautions and operation techniques before using pu
ページ10に含まれる内容の要旨
QP-204H — SPECIFICATIONS/DIMENSIONS (PUMP) Table 1. Specifications (Pump) MH odel QP-204 Tp ype Centrifugal Pum S) uction & Discharge Size 2.00 in. (51 mm. Pump Maximum Pumping 142 gallons/minute Capacity (538 liters/minute) M) ax. Lift 25 ft. (7.62 meters M) ax. Head 115 ft. (35.0 meters 19.0 x 14.0 X 16.0 in. Dimension (L x W x H) (48 X 35 X 40 cm.) Dry Net Weight 57 lbs. (26 Kg.) 16.0 IN. (40 CM.) 14.6 IN. (35 CM.) 19.5 IN. (49.5 CM.) Figure 1. QP-204H Dimensions PAGE 10 — QP-204H CENTRIFUGA
ページ11に含まれる内容の要旨
QP-204H — SPECIFICATIONS/DIMENSIONS (ENGINE) Table 2. Specifications (Engine) HONDA Model GX120K1PX2/GX120U1PX2 Air-cooled 4 stroke, Single Type Cylinder, OHV, Horizontal Shaft Gasoline Engine 2.7 in. x 1.8 in. Bore X Stroke (68 mm x 45 mm) D) isplacement 163 cc (9.9 cu-in M. ax Output 5.5 H.P./3600 R.P.M Engine Approx. 0.95 U.S. gallons Fuel Tank Capacity (3.6 liters) Unleaded Automobile Fuel Gasoline L) ube Oil Capacity .60 liters (0.63 qts Speed Control Centrifugal Fly-weight Type Method St t
ページ12に含まれる内容の要旨
QP-204H — GENERAL INFORMATION APPLICATION Elevation The QP204H Centrifugal Pump is designed to handle all types Higher elevations will effect the performance of the pump. Due to of clear water applications. It is ideal for residential use such as less atmospheric pressure at higher altitudes, pumps DO NOT dewatering basements and swimming pools. Both the suction have the priming ability that they have at sea level. This is due to and discharge ports on the QP-204H pump use a 2-inch diameter
ページ13に含まれる内容の要旨
QP-204H — PUMP COMPONENTS Figure 2 shows a typical application using the QP-204H centrifugal pump. Please note that this pump is intended for the removal of clean water. Figure 2. QP-204H Pump Application 1. Pump – The model QP-204H is 2-inch centrifugal pump 6. Suction Port – Connect a 2-inch inlet hose to this port. used in general de-watering applications. Typical Use two worm clamps to secure the hose. dewatering applications consist of dewatering basements 7. Suction Hose – Connect this
ページ14に含まれる内容の要旨
QP-204H — REFUELING DANGER - Fueling The Engine If pump is placed in a truck bed with a plastic liner, REMOVE pump from truck bed and place on ground (Figure 3) to refuel. The possibility of fire or explosion exists, due to static electricity. Figure 3. Pump Refueling PAGE 14 — QP-204H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL — REV. #3 (06/05/06)
ページ15に含まれる内容の要旨
QP-204H — BASIC ENGINE Figure 4. Engine Controls and Components INITIAL SERVICING 6. Choke Lever – Used in the starting of a cold engine, or in cold weather conditions. The choke enriches the fuel The engine (Figure 4) must be checked for proper lubrication and mixture. filled with fuel prior to operation. Refer to the manufacturers engine 7. Air Cleaner – Prevents dirt and other debris from entering manual for instructions and details of operation and servicing. The the fuel system. Remove
ページ16に含まれる内容の要旨
QP-204H — PRE-INSPECTION (ENGINE) Pre-Inspection (Engine) 1. Read safety instructions at the beginning of manual. 2. Clean the pump, removing dirt and dust, particularly the engine cooling air inlet, carburetor and air cleaner. 3. Check the air filter for dirt and dust. If air filter is dirty, replace Figure 6. Engine Oil Dipstick (Oil Level) air filter with a new one as required. 4. Check carburetor for external dirt and dust. Clean with dry Table 5. Oil Type compressed air. Season Temperatur
ページ17に含まれる内容の要旨
QP-204H — PRE-SETUP (PUMP) Pre-Setup (Pump) Suction and discharge hoses are 1. Read safety instructions at the NOTE available from Multiquip. Contact beginning of manual. your nearest dealer for more information. 2. Place pump as near to water as possible, on a firm flat, level surface. 5. The discharge hose is usually a collapsible (thin-walled) 3. To prime pump, remove fill cap (Figure 2) and fill pump casing hose, however if a thin-walled discharge hose is not avail- with water. If the pump
ページ18に含まれる内容の要旨
QP-204H — INITIAL START-UP (ENGINE) 3. Place the choke lever (Figure 9) in the "CLOSED " position CAUTION - Read Manual if starting a cold engine. DO NOT attempt to operate the pump until the Safety, General Information and Inspection sections of this manual have been read and thoroughly understood. This section is intended to assist the operator with the initial start-up of the trash pump. It is extremely important that this section be read carefully before attempting to use the pump in the
ページ19に含まれる内容の要旨
QP-204H — INITIAL START-UP (ENGINE) 6. Grasp the starter grip (Figure 12) and slowly pull it out. The CAUTION - Maximum Engine Speed resistance becomes the hardest at a certain position, corre- sponding to the compression point. Pull the starter grip briskly ALWAYS run engine at full speed while pumping. and smoothly for starting. Stopping The Engine Normal Shutdown 1. Move the throttle lever to the IDLE position (Figure 15) and run the engine for three minutes at low speed. Figure 12. Start
ページ20に含まれる内容の要旨
QP-204H — MAINTENANCE (PUMP) Pump Vacuum Test 7. If the vacuum tester gauge indicates a reading below -20 in. Hg, it can then be assumed that the pump CAUTION - Pump Priming is not functioning correctly, and corrective action needs to be taken. DO NOT attempt to start the engine unless the pump has previously been primed with water. Severe pump damage 8. To test the flapper valve, shut down the engine. The will occur if pump has not been primed. vacuum tester should remain attached to the pump