ページ1に含まれる内容の要旨
de
Installation and Operation Guide
Crystalline Solar Modules
Bosch Solar Module c-Si M 60 IN30125
en Operating instructions
Issue 01/2013
Bosch Solar Module c-Si M 48 I Bosch Solar Module c-Si M60 I Bosch Solar Module c-Si M60 S I Bosch Solar Module c-Si P60 Robert Bosch GmbH
deutsch
ページ2に含まれる内容の要旨
2 | Table of Contents I Introduction en en Disclaimer of liability I General information | 3 the Module Data Sheet provided with this product. De- Table of Contents 2 Disclaimer of liability termine local permits, installation and inspection re- quirements before installing module(s). If not otherwise Since the use of this Installation, Operation and Mainte- specified, it is recommended that the requirements of 1 Introduction 2 nance Manual and the conditions of installation, opera- the U.S. N
ページ3に含まれる内容の要旨
4 | General information I General safety en en General safety I Installation | 5 Provide suitable guards to prevent contact with 4. Under normal conditions, a photovoltaic module is sonally, yearly). The location should be selected to 4 Genaral safety 30 VDC or greater. As a Precaution use properly insu- likely to experience conditions that produce more have direct access to sunlight from 9:00a.m. to lated tools only. current and/or voltage than reported at Standard 3.00p.m. on the shortest
ページ4に含まれる内容の要旨
6 | Installation en en Installation | 7 990 ± 2 2x Mounting holes for 18,5 grounding cable size: 8 x 12 mm Figure 1: Mounting area, vertical 18 l/7 l/7 l mounting holes Figure 3: reverse side Bosch Solar Module c-Si M 60 IN30125 l/4 l/2 l/4 Figure 2: Mounting area, horizontal Bosch Solar Module c-Si M 60 IN30125 Bosch Solar Energy AG Bosch Solar Module c-Si M 60 IN30125 Bosch Solar Energy AG Ø 5 l/7 l/7 l mounting holes l/4 l/2 l/4 1660 ± 2 830 1000 267,5 375 8x M
ページ5に含まれる内容の要旨
8 | Grounding | Maintenance and upkeep | Disposal en en Specification I Wiring | 9 Notes on Installation The installation place should be less than 1,000 m 6 Specification 7 Wiring Clearance between the module frame and the mount- (3,280ft) above sea level. ing surface is required to allow cooling air to circu- Installations more than 1,000 m (3,280 ft) are allowed late around the back of the module. This also allows only if the wind pressure load for a module is less 60 Cell Module Seri
ページ6に含まれる内容の要旨
10 | Wiring | Grounding en en | Diodes Maintenance | 11 The term “array” is used to describe the assembly of away by periodic rainfall, but in some instances some 8 Grounding 9 Diodes several modules on a support structure with associ- maintenance is recommended to clean the surface of ated wiring. Use copper wire that is sunlight resistant the glass with water and a soft cloth or sponge. A and is insulated to withstand the maximum possible Bypass Diodes mild non-abrasive detergent may be
ページ7に含まれる内容の要旨
de Bosch Limited Hosur Road, Adugodi Bangalore 560 030 Indien Tel.: + 91 80 6657 1600 Mobil: + 91 97 4149 6854 www.bosch-solarenergy.com Bosch Solar Module c-Si M 48 I Bosch Solar Module c-Si M60 I Bosch Solar Module c-Si M60 S I Bosch Solar Module c-Si P60 Robert Bosch GmbH